YS88_kjh_e.pdf - 第3页
YS88 Over view Control box I/O conveyor -1- I/O conveyor -2- I/O conveyor -3- Head Camera unit sel. Operation panel sel. FIX24 feeder structure FIX32 feeder structure FES24 feeder structure FES32 feeder structure FIX24 f…

Safety.
To replace the purchased parts safely, be sure to comply with the following items.
However the following cannot cover all items regarding safety in detail. So it is
extremely important that the worker or person handling the machine make correct
decisions regarding safety.
CAUTION Machine operation of operator•Work is limited to maintenance and
safety skill.
Besuretoturnothemachine’spowersupplybeforedoingtheexchangework.
Be sure to push the emergency stop SW, and do adjustment work under the
emergency stop condition.
Refer to the manual for the replacement work of each consumable part.
*
Safety alert symbols and signal words
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor
injury, or material loss or damage to the machine. These points are important for
protecting the safety of the machine and data, etc.
安全について
お買い上げいただいたパーツを安全に交換していただくために、下記の事項は必ず守って作
業を行ってください。しかしながら、下記に全ての安全性に関する項目を細部にわたり網羅
することは困 難です。 従って作業 者自身 の安 全に対 する正確な判 断が 非常に 大切な要素とな
りま すことをご 留意ください。
注意 作業者は本機の動作・メンテナンスに習熟していて安全に作業を行える方に限り
ま す。
① 交換作業は、マシンの電源を切ってから必ず行ってください。
②調整作業は、非常停止 SW を押し、非常停止状態で必ず行ってください。
③ 消耗品の交換、 各メンテナンス作業についてはマニュアルをご参照ください。
※安全標記の 注意は取り扱いを誤った場合、傷害に至る可能性または物的損害の発生
が想定される内容を示しています。本体およびデータなどの損傷を防ぐために重要な注
意 事 項 で す。
YS88
Over view
Control box
I/O conveyor -1-
I/O conveyor -2-
I/O conveyor -3-
Head
Camera unit sel.
Operation panel sel.
FIX24 feeder structure
FIX32 feeder structure
FES24 feeder structure
FES32 feeder structure
FIX24 feeder structure(S-ATS)
Ionizer assy option
Power transformer
Power circuit
Emergency circuit
Air circuit (YS88)
Air circuit (YS88)FES
Air circuit (YS88)
Air circuit (YS88)
Wiring parts list
Table of contents
Condential & Proprietary
P.1
P.2
P.3
P.4
P.5
P.6
P.7
P.8
P.9
P.10
P.11
P.12
P.13
P.14
P.15
P.16
P.17
P.18
P.19
P.20
P.21
P.22

Confidential & Proprietary
PAGE
TERMINAL
3∼ AC220V3∼ AC220V3∼ AC220V3∼ AC220V
1∼ AC220V
3∼ AC220V
1:1.30KW(TOTAL)
1:1.30KW(TOTAL)
2:2.36KW(TOTAL)
1:1.36KW(TOTAL)
3∼ 200V 0-375Hz
3:0.48KW(TOTAL)
4:0.48KW(TOTAL)
2:2.36KW(TOTAL)
dYTF
3:1.30KW(TOTAL)
STANDARD
sATS
2:2.36KW(TOTAL)
MOTOR:3∼ 220V
AC50/60Hz 20A(MAX)
DRIVER
OUTPUT:
AC50/60Hz 4.0A(MAX)
CONTROL:1∼ 100V
INPUT:
CONTROL BOX
DC24V
COMU
COMU
COMU
COMU
COMU
COMU
DC24V
DC24V2
DC24V
DC24V
DC24V
See Page 3-5
CN1-CN14 …Page 3
CN17-CN20…Page 4
DC24V21∼ AC100V
GS22 600W 27A
Power Supply
QF41 7A
1∼ AC100V
DC24V
GS21 300W 14A
Power Supply
QF21 7A
I/O CONVEYOR BOARD
(OPTION)
BARCODE READER
USB MEMORY
Each Motors
OPERATION PANEL SEL.
See Page 8
See Page 7
MULTI CAMERA UNIT
See Page 2
IONIZER ASSY(OPTION)
FAN
VALVE
SENSOR
CONVEYOR MOTOR 30W
SIGNAL TOWER
COVER S/W
EMG S/W
INTERCONNECTION DIAGRAM
See sATS,dYTF
sATS,dYTF
TRAY CHANGER(OPTION)
1∼ AC100V
KM12/KM12A
GS31 600W 7A
DC48VDC48V
Contactor
Peak 15.5A 10sec
Power Supply
KM11/KM11A
DRIVER
CONVEYOR MOTOR
EMERGENCY CIRCUIT
KM10
CH1CH2K2 K1
Safety Relay
QF26 4A
QF24 20A
POWER CIRCUIT
3∼3∼
1∼ AC100V
DC24VDC24V
QF23 12A
QF25 4A
Contactor
NF11
TC11
1.75KVA(with UPS)
1.5KVA(STD)
Noise
Filter
Circuit
Protector
TM11 1.7KVA
Transformer
Transformer
POWER TRANSFORMER
XB11
QS11 25A QF11 20A
Main Breaker
Main Switch
Terminal
380/400/416V
200/208/220/240
3∼ 50/60Hz
CN21-CN44…Page 5
F.FEEDER
See Page 9
FIX24
See Page 10
See Page 11
R.FEEDER
FIX24
See Page 9
See Page 10
FES32
See Page 12
See Page 13
FIX32
FES24
See Page 11
See Page 12
FIX24+sATS
FIX32
FES24
FES32
I/O HEAD
See Page 6
DC48V
DC24V
FAN
HEAD SENSOR,VALVE
Z,R SERVO MOTOR
COMU
DC24V2
COMU
DC24V2
COMU
DC24V2
See Page 16
See Page 15
See Page 17
See Page 14
Rating 6.1KVA MAX.
QF31 set5A
(4-6.3A)
CC.V6
1
OVER VIEW
YS88