Nordson_EFD_8000_Data_Sheet.pdf - 第2页
Filter Regulator Low Pressure Switch Alarm In T ank Air Line Fluid Feed Line EFD valves Actuating Air Solenoid Solenoid Cable 1 -Liter T ank ValveMate 8000 Controller EFD V alveMate controllers featur e microprocessor ci…

The fastest, most precise way to adjust uid deposits
ValveMate 8000 Controller
Valve open time is the primary control of
deposit size.
Deposit size is determined by a combination of
uid pressure, valve stroke, tip size and valve
open time, with valve open time providing
the greatest control over the amount of uid
dispensed.
The Nordson EFD ValveMate
™
8000 controller is
a fast, convenient way to adjust valve open time
in increments as small as 0.001 seconds, right at
the dispensing station. The result is exceptional
process control without time-consuming
programming or mechanical adjustments that
require the production line to be shut down.
Features and Benefits
• Maximum process control
• “On the y” deposit adjustment
• Dispensing lines run at optimum speed
• Cost-effective — one ValveMate 8000 can
control 1, 2, 3, or 4 valves
• Simple to set up and operate
• Easily interfaced with a PLC
Operate up to four valves independently
or simultaneously.
ValveMate controllers provide the primary control of deposit size.
Part # Description
7022004 8000 Multi-Valve Controller
7022246 Single In-line Solenoid
7022247 Dual Solenoid Block
7022248 Tri Solenoid Block
7022249 Quad Solenoid Block
more info
“We had a skilled technician
spending 8 to 10 hours a week
adjusting equipment. By putting
a controller at each dispensing
station, we’ve reduced that time
to almost zero.”
– A.T. Cross Company

Filter
Regulator
Low Pressure
Switch
Alarm In
Tank Air Line
Fluid Feed
Line
EFD valves
Actuating
Air
Solenoid
Solenoid
Cable
1 -Liter Tank
ValveMate
8000 Controller
EFD ValveMate controllers feature microprocessor
circuitry for extremely precise control of deposit size.
Feed lines can be purged, initial deposit sizes set, and
adjustments made quickly and easily at the dispensing
station, without stopping the production line.
ValveMate controllers are simple to set up and operate,
and are easy to interface with PLCs and other equipment.
When the signal to start the cycle is received, the
ValveMate’s microprocessor takes over and regulates the
amount of uid dispensed. At the end of the cycle, the
ValveMate signals that the process has been completed.
Automated Dispensing Systems
Nordson EFD automated dispensing systems deliver
market-leading repeatability and accuracy in uid
placement and positioning. Specialized dispensing
software simplies setup and programming. Optimize
dispensing results with features such as laser height
sensing and smart vision CCD cameras.
Select Your Valve
See the Valve Selection Guide for the valves compatible
with this controller — www.nordsonefd.com/ValveGuide.
Request a Process Evaluation
Contact Nordson EFD to congure a precision dispense
system that meets your specic needs, with:
• A complimentary process evaluation by experienced
uid dispensing experts.
• Samples processed for customer evaluation and
approval prior to purchase.
Specifications ValveMate 8000 Sample Setup
Item Product
Cabinet size 18.3
W x 5.1H x 8.6D cm (7.20W x 2.00H x 3.38D")
Weight 0.3 kg (0.6 lb)
Cycle rate Exceeds 600 per minute
Time range 0.001–99.9 s
Input AC
(to power supply)
100–240 VAC, 50/60Hz
Output DC
(from power supply)
24 VDC, 1.25 Amp maximum
Feedback circuits 5 to 24 VDC NC solid-state switch
100 mA maximum
Cycle initiate 5–24 VDC signal
Approvals CE, TUV, RoHS, WEEE, China RoHS
Warranty 1 year, limited
For Nordson EFD sales and service in over 40 countries,
contact Nordson EFD or go to www.nordsonefd.com.
Global
800-556-3484; +1-401-431-7000
info@nordsonefd.com
Europe
00800 7001 7001
infoefd.europe@nordsonefd.com
Asia
China: +86 (21) 3866 9006; china@nordsonefd.com
India: +91 80 4021 3600; india@nordsonefd.com
Japan: +81 03 5762 2760; japan@nordsonefd.com
Korea: +82-31-736-8321; korea@nordsonefd.com
SEAsia: +65 6796 9522; sin-mal@nordsonefd.com
©2021 Nordson Corporation v041921