Printer 710-810 v9 Interchangeable Under Screen Cleaner Module.pdf - 第12页
INTERCHANGEABLE UNDER SCREEN CLEANER MODULE REPLACEMENT PROCEDURES 25.12 Technical Reference Manual Chapter Issue 5, Ju l 16 and understood. When repla cing a spray bar , ensure the tubing is unused. T o replace the spra…

INTERCHANGEABLE UNDER SCREEN CLEANER MODULE
REPLACEMENT PROCEDURES
Chapter Issue 5, Jul 16 Technical Reference Manual 25.11
REPLACEMENT PROCEDURES
Spray Bar
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. SAFETY GLOVES MUST BE WORN.
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. EYE PROTECTION MUST BE WORN.
Spray bars and paper rolls are interchangeable. Three unit sizes are available.
Each spray bar is fitted to a base, underneath the base is a solvent feed tube
and a connector.
Ensure that the solvent advice at the beginning of this chapter has been read
400
300
520
Spray BarSpray Bar
Feed TubeFeed Tube
BaseBase

INTERCHANGEABLE UNDER SCREEN CLEANER MODULE
REPLACEMENT PROCEDURES
25.12 Technical Reference Manual Chapter Issue 5, Jul 16
and understood. When replacing a spray bar, ensure the tubing is unused.
To replace the spray bar proceed as follows:
1. Ensure that the printer is electrically isolated.
2. Open the printhead front cover.
3. If required, pull the USC to the front of the printer.
4. Remove the paper roll.
5. Locate the four M3 captive screws that attach the base to the cleaner unit.
6. Using a 2.5mm Allen key loosen the four screws.
7. Lift the spray bar mechanism away from the USC frame slowly to expose
the connector underneath the spray bar.
8. Disconnect the spray bar feed tube from the left hand side of the connector.
9. Connect the spray bar tube of the replacement unit to the solvent tube
connector.
10. Align the replacement unit in the USC frame making sure that the feed tube
is not trapped.
11. Tighten the four M3 captive screws.
12. Tighten the solvent pump connector onto the solvent pump.
13. Fit the paper roll into its holder. Tension the feed and take-up rollers with a
clean portion of paper across the spray bar.
14. Close the print head front cover.
15. Power up the printer.
16. In Diagnostics, select Screen Cleaner.
17. Select Next.
18. Select Toggle Solvent Pump.
M3 Screws (x 4)M3 Screws (x 4)
Solvent Tube
Connector
Solvent Tube
Connector

INTERCHANGEABLE UNDER SCREEN CLEANER MODULE
REPLACEMENT PROCEDURES
Chapter Issue 5, Jul 16 Technical Reference Manual 25.13
19. Press the Internal Light button. Check that the paper is being wetted evenly
across the spray area.
20. Exit Diagnostics.
21. Press the System button.
22. With the printer at the Ready Page, select Print.
23. Ensure that the correct cleaning cycles are performed.