10 STENCIL ALIGNMENT MODULE 10.5 REPLACEMENTS 192 TECHNICAL REFERENCE MANUAL DEK TQ 04/2021

10 STENCIL ALIGNMENT MODULE
10.5 REPLACEMENTS
TECHNICAL REFERENCE MANUAL DEK TQ 04/2021 191
16. Slide the pneumatic stencil clamp (2) into the slot in the bottom of the adaptor (1), with the
pneumatic fitting to the rear.
NOTE
Ensure that the stencil clamp is not pinched or folded as it is fitted into the adaptor.
A
A
2
1
17. Once the clamp is fully inserted, insert and tighten the securing retaining screw (1) into the
front underside of the adaptor.
1
18. Connect the pneumatic tube to the quick release fitting at the rear of the stencil clamp.
19. Repeat the above procedure for the remaining stencil clamp.
20. Switch the Pneumatic Isolator to SUP.
21. Replace the front panel.
22. Replace the left-hand side panel.
23. Replace the right-hand side panel.
24. Replace rear upper cover.
25. Close front cover.
26. Switch the mains isolator to ON.

10 STENCIL ALIGNMENT MODULE
10.5 REPLACEMENTS