00193361-01.pdf - 第18页

Retrofit Instructions Splice Detection Table Controller S / F 07/2002 Edition 18  7 RROVDQG $X[LOLDU \ (TXL SPHQW – Metric Hex Ball End Wrench Set (als o calle d “All en” wren ch) – Diagon al Cutters – #1 Cross Point…

100%1 / 26
Retrofit Instructions Splice Detection Table Controller S / F
07/2002 Edition
17
 'HILQLWLRQV
DANGER
in terms of these instructions means that death, severe bodily injury or considerable material
damage WILL occur if the instructions about danger are not followed.
WARNING
in terms of these instructions means that death, severe bodily injury or considerable material
damage may occur if the warnings are not heeded.
CAUTION
in terms of these instructions mean that minor bodily injury or material may occur if the cautions
are not heeded.
NOTE:
in terms of these instructions is a statement of important information about the product or the
pertinent portion of the instructions to which particular attention is being drawn.
Retrofit Instructions Splice Detection Table Controller S / F
07/2002 Edition
18
7RROVDQG$X[LOLDU\(TXLSPHQW
Metric Hex Ball End Wrench Set (also called “Allen” wrench)
Diagonal Cutters
#1 Cross Point Screwdriver (also called a “Phillips Head” screwdriver)
A small flat bladed screwdriver.
 3DUWV
&RQWHQWV6SOLFH'HWHFWLRQWDEOHFRQWUROOHUNLW6)
LWHPQR 
Pieces Description Item no.:
- 1 table controller unit (TC) 00366004-01
- 1 CAT 5 cable 1,5m 00368328-01
- 1 power supply adapter 00368305-01
- installation material
Retrofit Instructions Splice Detection Table Controller S / F
07/2002 Edition
19
3UHSDUDWLRQV
: Read All Installation Instructions, and become familiar with the Splice Detect Table Controller
Kit, shown in Fig. 11 - 1:



power supply adapter cat 5 cable table controller