Printer 600 Machine Performance.pdf - 第2页
0$&+,1( 3(5)250$1 &( 0$&+,1( &$3$%,/,7< 8.2 Installatio n Manu al Chapter Issue 2 May 03 of pa ste or s uit able lubric ant (enoug h to lu bricate squee gees). Record > 100 full machine cycles and…

0$&+,1(3(5)250$1&(
0$&+,1(&$3$%,/,7<
Chapter Issue 2 May 03 Installation Manual 8.1
CHAPTER 8 MACHINE PERFORMANCE
MACHINE CAPABILITY
Load the product file named 265test2 from the hard disk and with a DEK
alignment board loaded ensure that the following parameters are correct:
• Screen - Calibration/Dry Align
• Squeegee - Length to suit board
• Board Width - 250mm
• Board Length - 250mm
• Board Thickness - 1.6mm
• Front & Rear Print Speed - 25mm/sec.
• Front & Rear Pressure - 5kg (3kg for ProFlow only machines)
• Under Board Clearance - 20mm
• Print Mode - Print/Print
• Tooling Type - Vacuum
• Transport Mode - Left to Left
• Print Paste Pressure - 2 bar (ProFlow only machines)
• Idle Paste Pressure - 0.2 bar (ProFlow only machines)
Ensure that the following SPC Configuration parameters are correct:
• Data Output Rate - Every Cycle
• Start Rate - 1 Cycle
• Sample Rate - 0 Cycles
• Start Rate Limit - 0 Cycles
• SPC Data Mode - Disk
• SPC Format - Windows
• Update On Start-up - Yes
• Align Inspect Mode - Pre + Post Print
Ensure that the following Edit Outputs in SPC Configuration are correct:
• X Alignment Deviation - Yes
• Y Alignment Deviation - Yes
• Theta Alignment Deviation - Yes
• Front Pressure - Yes (No for ProFlow only machines)
• Rear Pressure - Yes (No for ProFlow only machines)
• X Pre Alignment Deviation - Yes
• Y Pre Alignment Deviation - Yes
• Theta Pre Alignment Deviation - Yes
Use nine magnetic tooling pins to fully support the board, apply small amount

0$&+,1(3(5)250$1&(
0$&+,1(&$3$%,/,7<
8.2 Installation Manual Chapter Issue 2 May 03
of paste or suitable lubricant (enough to lubricate squeegees). Record >100 full
machine cycles and setup QC-Cal program as follows:
1. If squeegees are fitted ensure the filter files sqy1.qcf and sqy2.qcf are
present in the directory structure C:\Prolink\QcCalc\Filters.
2. Start the QC-Cal program.
3. Select Edit, Data.
4. Select Filters.
5. Select Select Filter Group.

0$&+,1(3(5)250$1&(
0$&+,1(&$3$%,/,7<
Chapter Issue 2 May 03 Installation Manual 8.3
6. Highlight sqy1.qcf file and select Open.
7. In the Record Filters Box, select sqy1 file and select O.K.