3 1. ݇Ѣᴀᴎ఼ⱘՓ⫼ : ᴀᴎ఼ᰃЎњᵓϞ䌈㺙⬉ᄤܗӊ 㗠䆒䅵ǃࠊ䗴ⱘDŽ 䇋ᇚᴀᴎ఼⫼ѢϞ䗄⫼䗨DŽ 䇋ϡ㽕⫼Ѣ݊ᅗ⫼䗨DŽ ݇Ѣᴀᴎ఼ⱘ᪡ : ᪡ᴀᴎ఼ⱘҎ䳔ফϧ䮼ⱘ䆁DŽ ফ䖛䆁ⱘҎਬ䇋࣓䖯㸠᪡DŽ ݇Ѣ䆁ˈ䇋䆶ᵒϟ⫳ѻ⾥ᡔ᷾ᓣ Ӯ⼒ PFSE DŽ ࠊ䗴ଚ : ᵒϟ⫳ѻ⾥ᡔ᷾ᓣӮ⼒ Ԥ䌎ও右ᷪᏖゟ⬎䭓㦆 441-13 ⬉䆱 :0942-84-2644 FAX:0942-84-2636 For Service …

2
SPECIFICATIONS
Item
Specifications
Mounting angle
0
°
to 359
°
(It can be set in increments of 0.01°.)
Mounting range
Refer to the Reference Manual.
Board flow direction
Refer to the Reference Manual.
Control system
Microcomputer system
External memory
Data is saved in PT. (Approximately 1 MB is required for saving a piece of data, depending on the
hard disk space of PT.) One type per 3.5-inch floppy disk
Program data
∗
1
Point count: Max. 10000 points
Machine body
Normal service source: Three-phase 200
±
10 VAC or 400
±
20 VAC
Frequency: 50/60 Hz
Peak current
value during
operation
CM401-M: 18 A
CM401-L: 15 A
CM402-M: 27 A
CM402-L: 20 A
Rated voltage 200 VAC: Measured based on our aging data
Take this into account when choosing the primary power
supply AVR (Stabilized power supply), etc.
(The peak current value varies depending on the operation
data.)
Power source
Power supply for
HUB
∗
3
Single-phase 100 VAC to 240 VAC, Frequency: 50/60 Hz
Machine body
CM401-M: 1.7 kVA
CM401-L: 1.6 kVA
CM402-M: 3.5kVA
CM402-L: 2.5 kVA
Rated capacity
Power supply for
HUB
∗
3
140 VA
Supply air pressure
0.49 MPa to 0.78 MPa (Working air pressure: 0.49 MPa to 0.54 MPa)
Supply air volume
150 L/min (A.N.R)
Outside dimension
CM401-M: 1260 mm (W)
×
2460 mm (D)
×
1462 mm (H)
CM401-L: 1260 mm (W)
×
2690 mm (D)
×
1462 mm (H)
CM402-M: 2350 mm (W)
×
2460 mm (D)
×
1462 mm (H)
CM402-L: 2350 mm (W)
×
2690 mm (D)
×
1462 mm (H)
∗
Three-color signal tower and color touch panels not included
Mass
∗
2
CM401-M: 1500
kg
(Standard configuration, excluding a collectively changing truck)
CM401-L: 1665
kg
(Standard configuration, excluding a collectively changing truck)
CM402-M: 2700
kg
(Standard configuration, excluding a collectively changing truck)
CM402-L: 3000
kg
(Standard configuration, excluding a collectively changing truck)
∗
(One) Collectively changing truck: 140
kg
Environmental
condition
Temperature: 10
°
C to 35
°
C
Humidity: 25% RH to 75% RH (No condensation)
Transportation and
storage condition
Temperature:
−
20
°
C to 60
°
C
Humidity: 75% RH or less (No condensation)
Altitude
1000 m or less, above sea level
Noise
< 70 dB (A)
∗
1: Data is created by PT.
This machine can only modify some data.
∗
2: Mass of the main body excluding the optional units
∗
3: The power supply for HUB is an option. This power supply is required when you wish to
communicate with PT while the main power supply is OFF.
4Z4C-E-PLA00-A01-05

3
1.
݇Ѣᴀᴎ఼ⱘՓ⫼
:
ᴀᴎ఼ᰃЎњᵓϞ䌈㺙⬉ᄤܗӊ㗠䆒䅵ǃࠊ䗴ⱘDŽ
䇋ᇚᴀᴎ఼⫼ѢϞ䗄⫼䗨DŽ
䇋ϡ㽕⫼Ѣ݊ᅗ⫼䗨DŽ
݇Ѣᴀᴎ఼ⱘ᪡
:
᪡ᴀᴎ఼ⱘҎ䳔ফϧ䮼ⱘ䆁DŽ
ফ䖛䆁ⱘҎਬ䇋࣓䖯㸠᪡DŽ
݇Ѣ䆁ˈ䇋䆶ᵒϟ⫳ѻ⾥ᡔ᷾ᓣӮ⼒
PFSE
DŽ
ࠊ䗴ଚ
:
ᵒϟ⫳ѻ⾥ᡔ᷾ᓣӮ⼒
Ԥ䌎ও右ᷪᏖゟ⬎䭓㦆
441-13
⬉䆱
:0942-84-2644
FAX:0942-84-2636
For Service and Supply of Spares in Europe
you may contact Panasonic Europe:
Continental Europe
PFSE
Panasonic Factory Solutions Europe
Winsbergring 15
22525 Hamburg Germany
Phone number: 0049-(0)40-85386-321
Fax number: 0049-(0)40-85386-332
United Kingdom
PFSE
Panasonic Factory Solutions Europe
Panasonic House,Willoughby Road
Bracknell, Berks. RG12 8 FP
Phone number: 0044-(0)1344-853267
Fax number: 0044-(0)1344-425970
Year: 2008
4Z4C-C-PLB00-A01-01

4
㾘Ḑ
乍Ⳃ 㾘Ḑ
ᅲ㺙㾦ᑺ
0
°
~ 359
°
(
㾦ᑺҹ
0.01
°
Ўऩԡৃ䖯㸠䆒ᅮ
)
ᅲ㺙㣗ೈ খ✻খ㗗ݠ
ᵓ⌕ࡼᮍ খ✻খ㗗ݠ
ࠊᮍᓣ ᖂᴎᮍᓣ
䚼ᄬټ఼
PT
Ёֱᄬ᭄DŽ
(
ḍ
PT
ⱘ
HD
ᆍ䞣ˈ↣㒘᭄䳔㽕㑺
1 MB) 3.5
䕃Ⲭ
1
Ͼક⾡
/
ᵮ
ᑣ᭄
∗
1
⚍᭄
Max. 10000
⚍
ᴎ఼Џԧ
ℷᐌՓ⫼⬉⑤
: 3
Ⳍ
AC 200 V
±
10 V
AC 400 V
±
20 V
乥⥛
:50/60 Hz
䖤䕀Ёⱘ⬉⌕
ዄؐ
CM401-M: 18 A
CM401-L: 15 A
CM402-M: 27 A
CM402-L: 20 A
ḍ乱ᅮ⬉य़
AC200 V
ᴀ⼒㗕᭄࣪⌟ᅮDŽ
䗝ᅮ߱㑻⬉⑤
AVR (
〇ᅮ࣪⬉⑤
)
ㄝᯊˈ䇋㗗㰥DŽ
(
ḍ䖤䕀᭄ˈ⬉⌕ዄؐӮ᳝বࡼDŽ
)
⬉⑤
HUB
⫼⬉⑤
∗
3
ऩⳌ
AC 100 V ~ AC 240 V
乥⥛
:50/60 Hz
ᴎ఼Џԧ
CM401-M: 1.7 kVA
CM401-L: 1.6 kVA
CM402-M: 3.5 kVA
CM402-L: 2.5 kVA
乱ᅮᆍ䞣
HUB
⫼⬉⑤
∗
3
140 VA
կ㒭⇨य़
0.49 MPa ~ 0.78 MPa (
䖤䕀ぎ⇨य़Ў
0.49 MPa ~ 0.54 MPa)
կ㒭ぎ⇨䞣
150 L/min (A.N.R)
ᔶሎᇌ
CM401-M: 1260 mm (W)
×
2460 mm (D)
×
1462 mm (H)
CM401-L: 1260 mm (W)
×
2690 mm (D)
×
1462 mm (H)
CM402-M: 2350 mm (W)
×
2460 mm (D)
×
1462 mm (H)
CM402-L: 2350 mm (W)
×
2690 mm (D)
×
1462 mm (H)
∗
ϡ
3
↉ֵোศᔽ㡆㾺䴶ᵓ
䋼䞣
∗
2
CM401-M: 1500
kg
(
ᷛޚᵘ៤ϡᭈԧѸᤶৄ䔺
)
CM401-L: 1665
kg
(
ᷛޚᵘ៤ϡᭈԧѸᤶৄ䔺
)
CM402-M: 2700
kg
(
ᷛޚᵘ៤ϡᭈԧѸᤶৄ䔺
)
CM402-L: 3000
kg
(
ᷛޚᵘ៤ϡᭈԧѸᤶৄ䔺
)
∗
ᭈԧѸᤶৄ䔺
(1
ৄ
): 140
kg
⦃๗ᴵӊ
⏽ᑺ
:10
°
C ~ 35
°
C
ᑺ
:25% RH ~ 75% RH (
Ԛ∈≑ϡޱ㒧
)
ᨀ䖤ᬒ㕂ᴵӊ
⏽ᑺ
:-20
°
C ~ 60
°
C
ᑺ
:75% RH
ҹϟ
(
Ԛ∈≑ϡޱ㒧
)
催ᑺ Ң⍋ᢨ
0 m
㟇
1000 m
ҹϟ
ా䷇
< 70 dB (A)
∗
1:
⫼
PT
㓪ࠊ᭄DŽᴀᴎা㛑ׂℷϔ䚼ߚ᭄DŽ
∗
2:
Џԧ䋼䞣ϡࣙᣀ䗝䌁ӊ䚼ߚDŽ
∗
3: HUB
⫼⬉⑤Ў䗝䌁ӊDŽेՓЏ⬉⑤Ў
OFF
г㽕
PT
䖯㸠䗮ֵᯊˈ䳔㽕䆹⬉⑤DŽ
4Z4C-C-PLB00-A01-00