Item Object Notes
Target Model Refer to 1. Target Model
V3.31STD R1.000 and later Support Version
History of revisions
No. Version Content of revision
00 V3.31STD R1.000 Created
01 V3.32STD R1.000 It is changed into retry by time interval from retry by feeder
drive count interval.
It is changed into execute individual pickup just after Pickup
MACS execution.
It is changed into execute Feeder Macs timing.
It is added setup method for 4mm feeder.
It is added [6.3. About Using with Pick Position Correct].
The change part is added (*1).
The information contained in this message may be co
nfidential and legally protected under applicable
law. The message is intended solely for the addressee(s).
If you are not the intended recipient, you are here
by notified that anyuse, forwarding, dissemination,
or
reproduction of this message is strictly prohibited and maybe unlawful.

SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50177
2/25
Contents
Pickup MACS................................................................................................................................. 1
1. Target Model .............................................................................................................................. 3
2. Summary....................................................................................................................................4
2.1. Feeder MACS .....................................................................................................................4
2.2. Nozzle MACS...................................................................................................................... 4
3. Setting........................................................................................................................................5
3.1. Machine Setting ..................................................................................................................5
3.2. Board data...........................................................................................................................7
4. Details ........................................................................................................................................8
4.1. Feeder MACS .....................................................................................................................8
4.1.1. Execution Conditions.................................................................................................... 8
4.1.2. Execution Timing ..........................................................................................................8
4.1.3. Mark data for Feeder MACS ........................................................................................9
4.1.4. Case of Feeder MACS failure ...................................................................................... 9
4.1.5. Clear the correct value and retry ................................................................................10
4.1.6. Simultaneous Pickup ..................................................................................................10
4.1.7. Using with Pick Position Correct ................................................................................ 10
4.1.8. Retry by time interval (*1)...........................................................................................10
4.1.9. Pickup position trace function in teaching window .....................................................10
4.2. Nozzle MACS.................................................................................................................... 11
4.2.1. Execution Conditions.................................................................................................. 11
4.2.2. Execution Timing ........................................................................................................ 11
4.2.3. Nozzle MACS data .....................................................................................................12
4.2.4. Case of Nozzle MACS failure.....................................................................................12
4.2.5. Simultaneous Pickup ..................................................................................................12
4.2.6. Using with Pick Position Correct ................................................................................ 12
4.2.7. Nozzle MACS by manual operation ...........................................................................12
4.3. Error message...................................................................................................................16
5. Limitations................................................................................................................................17
5.1. Feeder MACS ...................................................................................................................17
5.2. Nozzle MACS....................................................................................................................17
6. Appendix ..................................................................................................................................18
6.1. Setting method of Feeder MACS mark data .....................................................................18
6.2. Setting method of Nozzle MACS mark data .....................................................................21
6.3. Using with Pick Position Correct (*1) ................................................................................24

SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50177
3/25
1. Target Model
Pickup MACS function consists of two functions [Feeder MACS] and [Nozzle MACS].
The target model and version of Feeder MACS are as follows.
Table1.1 Target model and version (Feeder MACS)
Target Model Target Version Remarks
YS24 Series
YS24X Series
YS12 Series, YS100
YS88, YSH20, YC8
VGOS V3.31 STD R1.000 and later
Y.FacT V1.31 STD R1.000 and later
The target machine is
equipped SS feeder.
The target model and version of Nozzle MACS are as follows.
Table1.1 Target model and version (Nozzle MACS)
対象機種 Target Version Remarks
YS24 Series
YS24X Series
YS12 Series, YG12,
YS100
VGOS V3.31 STD R1.000 and later
Y.FacT V1.31 STD R1.000 and later
The machine equipped
FNC is un-supported.