SC Program Sheet.pdf - 第2页

  Program Sheet Symbols Types Symbols Reading Logic conditions Monitoring Ind ica tion Actions Input       This symbol indicates the first priority of the c onditions that conform “OFF”.     …

100%1 / 97
Q140339E04
X
103AE
SC Program Sheet
Model No.
NM-AA30
NM-AA31
JVK3B
V01.11
AVK3
NM-EJA1
A
AVK3
JVK3B
High-Speed Axial Lead Component Insertion Machine
High-Speed Jumper Wire Insertion Machine
Program Sheet Symbols
Types Symbols Reading
Logic
conditions
Monitoring
Indication
Actions
Input


This symbol indicates the first priority of the conditions that conform “OFF”.









or
Output

 

 
Comp
ound
This symbol indicates the conditions”AND”,that conform”ON”.


Auxi
liary
This symbol indicates “OFF”of the output power(Lamp etc).

This symbol indicates the conditions”OR”,that conform”ON”.

This symbol indicates the first priority of the conditions that conform “ON”.
This symbol indicates the conditions”AND”,that conform”OFF”.
This symbol indicates the conditions”OR”,that conform”OFF”.
This symbol indicates”ON” (Self retainer)of the output power(Lamp etc).
This symbol indicates “ON”or”OFF” (Self retainer)of the output power(Lamp etc).
If conditions are satisfied in the line where symbol mark””exists,the program
is executed till the next””appears for the following lines.
If not,the program is not executed.
If signal(memory,output power)is set to ON,it is switched to OFF.
If signal(memory,output power)is set to OFF,it is switched to ON.
ADDRESS NO.
FUNCTION REMARKS
00000∼00077
 LOOP1(INPUT)
 (#8∼#F) IN
00100∼00177
 LOOP2(INPUT)
 (#8∼#F) IN
00200∼00277
 LOOP1(OUTPUT)
 (#0∼#7)OUT
00300∼00377
 LOOP2(OUTPUT)
 (#0∼#7)OUT
01000∼01377  MEMORY1
02000∼02177  IFR1  (M→S)
02200∼02377  IFR2  (M→S)
03000∼03077
SUB CONTOROL PANEL(INPUT) SUB CONTOROL PANEL SW
03100∼03177
SUB CONTOROL PANEL(OUTPUT) SUB CONTOROL PANEL LED
04000∼04077
 LOOP3(INPUT)
 (#8∼#F) IN
04100∼04177
 LOOP4(INPUT)
 (#8∼#F) IN
04200∼04277
 LOOP3(OUTPUT)
 (#0∼#7)OUT     
04300∼04377
 LOOP4(OUTPUT)
 (#0∼#7)OUT
05000∼05007  SYSTEM INFOMATION
05300∼05357  SC SOFT TIMER
TIMER START OUTPUT/TIMER UP INPUT
05360∼05377  COUNTER
COUNTER INC.OUTPUT/COUNTER UP INPUT
06000∼06017  COUNTER
COUNTER DEC.OUTPUT/COUNTER ACK.INPUT
06020∼06037
 COUNTER/SYSTEM INF.
COUNTER RESET OUTPUT/LOOP ERROR INPUT
07000∼07377  MEMORY2
12000∼12177  IFR1
(S→M)
12200∼12377  IFR2
(S→M)
【SC ADDRESS MAP】