If you want to analyze 2D inspection result, After selecting an inquire period and then click Inquire which you want to see the data on monitor 2D Inspection result data will be saved on HistoryDB.mdb. Please copy this f…

100%1 / 38
Embedded Standard Program
2D inspection
SPI closed Loop
Auto Squeegee
calibration
Auto Camera
calibration
Auto Stencil
inspection
Auto conveyor
adjustment
Auto Alignment
Accuracy for Table
and Camera
Easy Offset
Alignment
Auto Stencil
loading
PCB loading
direction check
PCB Barcode
traceability
ESE standard MES
Programming by
network
Program for auto
support tooling
Leading Edge & Advanced Technology
Standard 12 Effective. Useful program
Optional program available
Total Management system (TMS)
Hermes (machine to machine communication)
SEC.GEM / CFX
If you want to analyze 2D inspection result,
After selecting an inquire period and then
click Inquire which you want to see the
data on monitor
2D Inspection result data will be
saved on HistoryDB.mdb.
Please copy this file and open it
on Excel
All ESE ES-E & H printer has 2-D
inspection function basically to verify
solder Less, Excess, Shortage and
Position Error
2D inspection
SPI closed loop
The solder pasted board inspection of X, Y, Theta
Sending information to Printer
printer X, Y, Theta axis deviation adjust
Cleaning request
SPI : KOHYONG, PARMI, PEMTRON, TRI, CYBEROPTIC
Receiving information from SPI
printer X, Y, Theta axis deviation adjust
Cleaning request
Offset changing window Image
Auto Squeegee Z center position Calibration
Auto Camera Calibration
What this function is :
The function is to set automatically Squeegee down position to print by
a setting pressure after squeegee holder set fixing to machine
Why this function needed :
During production, squeegee blade or squeegee holder set need to be
changed and in this case, the squeegee height can be different. And
also in case a printing quality is not good or mask stenicl thickness
changed or table up position changed, if customer use this function,
customer can take much perfect printing condition of squeegee
automatically than manual works
What the automatic camera calibration is :
The function calculates Actual image size (mm) per Pixel by
recognizing Image size (pixel) to actual image size (mm) on
Vision [ unit : mm/pixel ]
Why this function needed :
To realize the perfect Offset by motor comparing the position
between fiducial image and actual position(mm)
To make sure correct camera focusing when a camera has a
damage from a physical conflict or a camera replaced or a
camera disassembled or re-assembled