3.20 1.000 TP1453
TP1453TP1453
TP1453 1
11
1
Important
ImportantImportant
Important
Add
AddAdd
Add
All
Application
Added
Machine
Thefollowingmachinehasbeensupported.
1.YS24X
Itismodified.
3.20 1.000 TM2092
TM2092TM2092
TM2092 2
22
2
Important
ImportantImportant
Important
Add
AddAdd
Add
YS24Series
Vaccum
Backup
Whenaboardisfixed,"Vacuumbackup"functionhasbeenadded.
Whenanyofthefollowingconditionswassatisfied*,aboardisvacuumedatthetimeof
fixinginordertopreventaboardfromshiftingduringmounting.
1.[Setting]–[MachineInformation]–[InstallationSetting]–[VacuumBackup]is
1)"PriorityRelease":Itischeckedwhethervacuumisgeneratedtocompletefixinga
board.
2)"AllRelease":Itisnotcheckedwhethervacuumisgeneratedtocompletefixinga
board.
When"None"isselected,aboardisfixedwithoutvacuuming.
*Thisfunctionneedsvacuumbackupunitasoption.
Itismodified.
3.20 1.000 TM1982
TM1982TM1982
TM1982 3
33
3
Important
ImportantImportant
Important
Add
AddAdd
Add
YS24X
Machine
Nozzlestation
Thenozzlestationcanusetheholeof96inthemaximum.Afunctiontosetthemount
table(AorB)whichanozzlestationnumberbelongstowasadded.
Itismodified.
*
3.20 1.000 TT4938
TT4938TT4938
TT4938 4
44
4 CriticalBug
CriticalBugCriticalBug
CriticalBug Printer ConveyorOut
When"aboardcarry-infromtheupstreammachine"and“aboardcarry-outtothe
downstreammachine"occurredatthesametime,therewasabugthatthemachine
becameahung-upandthemachineneededtoberestarted.
Itisfixed.
3.20 1.000 TM2076
TM2076TM2076
TM2076 5
55
5 Add Printer PSC
ThefunctionhasbeenaddedthatthePSCunitismovedtotheescapepositionwhen
thesqueegeeisexchangedinordertomakeiteasier.
Itismodified.
3.20 1.000 TM2089
TM2089TM2089
TM2089 6
66
6 Change Printer PSC
Thecontrol*ofbrakeofSYaxishasbeenchangedduringemergencystoppingas
followsinordertopreventmovingPSCunittothedangerousposition.
Beforethechange:Thecontrolofbrakeisonlyexecutedjustafter[EMERGENCY
STOP]buttonispressed.(MovingSYaxistothedangerouspositionisavailableby
hand.)
Afterthechange:Thecontrolofbrakeisexecutingduringemergencystopping.
*WhenPSCunitexistsinthesafetyposition,SYaxisisreleased.Whenitexistsinthe
dangerousposition,thebrakeisputon.
Itismodified.
3.20 1.000 TT5004
TT5004TT5004
TT5004 7
77
7 Bug YS24 Auto-running
Whenthefollowingprocedureswereexecuted,therewasabugthatunnecessary
[Ea2204:BOARDTRANSFERERROR]occurred.
1.Loadtheboarddatawhose[BoardSizeX(mm)]is"330"orless.Startauto-running.
2.Whentheentrancestopperisraised,resetauto-running.
3.Loadtheboarddatawhose[BoardSizeX(mm)]is"330"ormore.Startauto-running.
4.Theentrancestopperdoesn’tlower.[Ea2204:BOARDTRANSFERERROR]occurs.
Itisfixedto
lowerthe
entrancestopper.
3.20 1.000 TT5025
TT5025TT5025
TT5025 8
88
8 Bug YS24 Auto-running
Whenthefollowingprocedureswereexecuted,therewasabugthatunnecessary
[Ea29556:INTERLOCKERROR]occurred.
1.Turnonthemachine,andperformreturn-to-origin.
2.Loadaboarddataduringemergencystop.
3.Startauto-runningwithoutresetting.
4.[Ea29556:INTERLOCKERROR]occurs.
Itisfixed.
3.20 1.000 TT5052
TT5052TT5052
TT5052 9
99
9 Bug YS24Series Dump
Whenallofthefollowingconditionsweresatisfied,therewasabugthatunnecessary
[Ea166:BOARDDATAERROR]erroroccurredwhenthedataischecked.
1.ThedumpstationexistsinBtable.
2.ThenumberthatisnotbelongingtoBtableisseton[Setting]-[MachineData]-
[Mechanical]-[Position]-[TableB]-[DumpStation1]or[DumpStation2]-[SetNo.].
Itisfixed.
3.20 1.000 KHn296
KHn296KHn296
KHn296 10
1010
10 Bug
YSSeries
Mounter
ErrorMessage
WhenanerroroccurredinthelinearencoderofX/Yaxis,therewasabugthatthe
followingerrormessagedisplayedbymistake.
Beforethecorrection:[Es00082:LinearEncoderPulseError]
Afterthecorrection:[Es00069:EncoderBreakA/B/C]
Itisfixed.
3.20 1.000 TT4930
TT4930TT4930
TT4930 11
1111
11 Bug Printer PSC
WhenPSCactionexceeded512timesafterselectingboarddata,therewasabugthat
thedisplayinggraphon[Monitor]-[PSCTransition]screenwasdifferentfromproper
plotting(itbecamerandomvalues).
Thisbugwasonlydisplayproblem,thescreenwasre-drawncorrectlybytapping
[Reset]buttononthesamescreen.
Itisfixed.
MDOC-VG30-00001 6/8

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNote(English) 2010/4/14
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.20 1.000 TT4947
TT4947TT4947
TT4947 12
1212
12 Bug Printer Printer
Whenthefollowingprocedureswereexecuted,therewasabugthattheprintingwas
executedwithusingsettingvaluesof"feedbackprint"evenifthestateoftheprinting
didnotneedtoexecute"feedbackprint".
1.Setanyofthefollowingsettingson[Inspection]-[Inspection].
1)[AfterManualCleaning]-[Inspection]is"Use".
2)[NormalRunning(Interval)]-[Inspection]is"Use".
3)[AfterDryAutoCleaning]-[Inspection]is"Use".
4)[AfterWetAutoCleaning]-[Inspection]is"Use".
2.Setanyofthefollowingsettingson[Inspection]-[Feedback]-[FeedbackPrint]-
[Feedback]combobox,andexecute"feedbackprint".
1)"Auto"
2)"Select"
3.Afterthat,theprintingwasexecutedwithconditionof"feedbackprint"evenifthe
stateoftheprintingdidnotneedtoexecute"feedbackprint".
Itisfixed.
3.20 1.000 TT4900
TT4900TT4900
TT4900 13
1313
13 Bug Printer Boarddata
Whenthefollowingprocedureswereexecuted,therewasabugthatthesolder-print
inspectionalwaysbecameNG.
1.Thefollowingbothitemsaredifferent.
1)[Setup]-[Board]-[BoardDatumPosition]combobox
2)[Inspection]-[Inspection]-[InspectionDatumPosition]combobox
2.Createanyboarddataandinspectiondata.
3.Change[BoardSizeX(mm)]or[BoardSizeY(mm)].
Itisfixed.
1.Whenboard
sizeischanged,
[Ea8776:Board
sizewas
changed.]is
displayedfor
warning.
2.Whennew
inspectiondatais
created,the
preceding1-1)
valueiscopiedto
1-2),andthen
thesetwovalues
becomethesame
value.
3.20 1.000 TT4921
TT4921TT4921
TT4921 14
1414
14 Bug Printer Boarddata
Therewasabugthatthedatacheckingtimewasincreasedabnormallyinproportionto
thenumberofInspectionView.(Thetimewasincreasedabout2.5secondsin12800
pointsofInspectionView)
Itisfixedthat
thedatachecking
timebecomes
within0.1
seconds.
3.20 1.000 TT4919
TT4919TT4919
TT4919 15
1515
15 Bug Optimizer Boarddata
Anoptimizationwasexecutedwhenallofthefollowingconditionsweresatisfied,there
wasabugthat[Ea663FailedtoreadBoarddata.]occurredandOptimizationfailed.
1.Boarddataformatis"YGX"or"VIOS-TEST".
2.Boarddatafileexistsinexcluding"No1"folder.
Itisfixed.
MDOC-VG30-00001 7/8

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNoteOption(English) 2010/4/14
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.20 1.000
TM1836
TM1836TM1836
TM1836
TM1837
TM1837TM1837
TM1837
TM1838
TM1838TM1838
TM1838
TM1839
TM1839TM1839
TM1839
TM1840
TM1840TM1840
TM1840
1
11
1
Important
ImportantImportant
Important
Add
AddAdd
Add
AllMachine
Op002:Setup
Verification
"Userdefinitionsetup"functionhasbeenaddedto"SetupVerificationOption
(Op002)".
Thisfunctionmakesiteasiertopreventmis-setupbyregisteringsetupitemssuchas
"Pushuppinplate","Bareboardpack"otherthansurface-mountedcomponents.
Itismodified.
*
3.20 1.000 TT4644
TT4644TT4644
TT4644 2
22
2 Bug Mounter
Op001:
Remain
Counter
Op002:Setup
Whenamachinewasstartedafterattachingcartorfeeder,therewasabugthat[MIS]
-[Setup]wasinitialized.
Itisfixed.
3.20 1.000 TT4889
TT4889TT4889
TT4889 3
33
3 Bug Mounter
Op001:
Remain
Counter
Op002:Setup
Verification
Whenthefollowingprocedureswereexecuted,therewasabugthatthelightingoftray
indicatorbecameanabnormalstateofthesetup(Red-lighting)evenifthesetupofthe
traypartswasdone.
1.[Parts]-[Tray]-[PalletNo.Start]numberthatisthesameas[FeederSetNo.]
existintwoormoreparts.
2.Operatethefeederpartstothestateofuncompletedsetup,andoperatethetray
partstothestateofcompletedsetup.
Itisfixedthat
theindicatoris
displayedwith
green(thestate
ofcompleted
setup)..
MDOC-VG30-00001 8/8