Test Research Inc. 104 TR7500 Series User Guid e –Softwa re v.2.9.0 Formula  i X = Result  n = count Test  n X ∑ = = i X Average  1 ) ( Sigma 2 − − = = ∑ n X X i σ        − − = σ σ 3 ) ( , 3 ) ( LSL X X USL Mi…

100%1 / 330
Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 103
Name Component Name
Theta_CpkSpec
CpkSpec for Theta
Theta_Cpk
Cpk for Theta
Missing
The number of missing.
X_Position
The result of X coordinate on CAD adds the average of X-
shift
Y_Position
The result of Y coordinate on CAD adds the average of Y-
shift
Status
It shows [NG] and displays yellow symbol when there’s a
[Missing] or [CpkCpkSpec]. Otherwise it shows [OK].
[Show Graphic] – Show the time sequence graph for selected component.
Select to display the graph of X-shift, Y-shift or Rotation.
The horizontal axis presents the count and the vertical means the result.
The red line means the average.
Figure 170: Time Sequence Graph
[Write To File] – Output the original data as text file.
[OK] – Close the window.
Test Research Inc.
104 TR7500 Series User Guide –Software v.2.9.0
Formula
i
X=
Result
n
=
countTest
n
X
==
i
X
Average
1
)(
Sigma
2
==
n
XX
i
σ
=
σσ
3
)(
,
3
)( LSLXXUSL
MinC
pk
USL and LSL present the upper spec limit and lower spec limit. Set the value when
starting this function.
3.10.11 Gauge Tool
Figure 171: Utilities Tab -- Gauge Tool Options
3.10.11.1 Gauge Fiducial 0-1 Repeatability (50 cycles)
System will measure the distance between two fiducial marks for 50 times and output the
result in [C:\AOI] folder. The first measurement file name is [fireport1.txt] and the next files
will be [fireport2.txt], [fireport3.txt] and so on. Select YES for static or NO for board in and out
test.
Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 105
Figure 172: Confirm Static or Board In/Out Test
3.10.12 Resend Image Data for Repair
This function is enabled when [Parameter/User Mode/Link to Repair Station] is selected.
Press the item and the system will send the data to repair station (Including *dir.1, *.win,
*.img, *.bmp).
3.10.13 Enable Inspection Data Collection
Select this item to save the result for all components as a text file. The file will be saved in
the folder that the project is saved in and the file name is “Year-Month-Date-Time”.
3.10.14 Component Status
This can only be selected in the [Train] dialog.
After selecting [Pass], [Fail] and [Untest], press [Refresh]. The system will display the number
of components which are passed, failed or untest.
Number of components
Figure 173: Component Status Dialog
3.10.15 Generate Real Image Data
Generate the image to ICT or ATE machine.