RO400FC-RO300FC-Specifications_V3.2.pdf - 第6页

RO300FC Reflow Ov en Version 3.1 FeM May 2017 Page 3 of 3 Specifications Option specification (cont .) Option Value Specification PCB Counter Sensor type Optical polarized Order numbers: Mesh belt RO300F C- 3B Chain conv…

100%1 / 6
Specifications
RO300FC
RO300FC-C
Machine base
Heating zones
3
3
Cooling zones
1
1
Air operation
Base console
PCB Handling
Mesh belt conveyor
Pin (chain) conveyor
SMEMA interface
RO300FC
RO300FC-C
Dimensions
Length x Width x Height
2'000x710x1'200 mm (78.8x28x47.2")
Weight
237 kg (523 lb)
237 kg (523 lb)
Control
Type
Microprocessor
Languages
English, German, French
Temperatures selectable
°C, °F
Program capacity
49 (10 preset standard, 10 preset leadfree, 10 preset curing, 19 free)
Board counter
optional with sensor or standard with SMEMA option
Gas temperature adjustment
Adjustable from 20° to 300°C ( 68° to 572°F) for each zone
Substrate dimensions
Max. reflow width
300 mm (11.8")
Substrate width
10-300 mm (0.39-
10-300 mm (0.39-
Conveyor
Transport direction
left to right
Pin length
-
3 mm (0.12")
Conveyor speed range
100- -
Conveyor speed repeatability
+/-2 mm (0.079
Conveyor motor type
24V DC with encoder
Rail parallelism
-
+/-
In feed length
Out feed length
Entrance height (max)
Free space below substrate
0
Process dimensions
Heated length
Length of heating zone
Length of active cooling zone
Overall length cooling zone
Process data
Total Air circulation heating zones
1'200 m
3
/h (706 cfm)
Air circulation per heating zone
400 m
3
/h (235 cfm)
Air circulation peak zone
400 m
3
/h (235 cfm)
Air circulation cooling zone
300 m
3
/h (177 cfm)
Atmosphere quality
air
air
Supplies
Electrical
EU: 3x400 VAC, 50Hz, 25 A
US: 3x208 VAC, 60Hz, 32 A (without transformer)
Power consumption
6.1 kW continuous, 10 kW (during initial heat up,15 min)
Minimum exhaust volume
2x250 m3/h = 500 m3/h (2x150 cfm=300 cfm). Option RO300FC-VNT recommended.
Filter / Air Cleaning Systems
No / must be added in the exhausting system
Exhaust specifications
1 each at entry and exit, distance 1,34 m (52.76"), diameter 80 mm (3.15"), length 40
mm (1.57"), gas temperature at exhaust <55°C (<131F)
Environment
Noise level
70 dB (A) maximum
Features
Emergency stop buttons
1 (on left side of the machine)
Main power disconnect
1 with undervoltage circuit breaker
Overheat security
Overheat temperature control for each zone (electronic detection)
Safety standards
CE, EN 954-1 Class 3
Color
White (RAL9002) silky lustre, fine structure
Specifications
Temperature Profile
Preheat 1
Preheat 2
Reflow
Cooling
Type
Convection
Convection
Convection
Convection
Max. gas temperature setting
300°C (572°F)
300°C (572°F)
300°C (572°F)
--
Max. Heating power
3000 W
3000 W
3000+2500 W
--
Regulation (Reflow conditions)
+/- 3°C
+/- 3°C
+/- 3°C
--
Ramp times (FR4 inboard measurem.)
1.8-2°C /sec
1.8-2°C /s
2-3°C /sec
2.5-3°C /sec
Temperature measurement
in airstream*
in airstream*
in airstream*
--
Heating up time from 20°C (68°F) to set
temperature 160 160 160 235°C
(320-320-320-455°F) (Typical used Profile)
6 min
4 min
8 min
--
T within 300 mm conveyor width
<4°C (39.2°F)
<4°C (39.2°F)
<4°C (39.2°F)
--
Cold start warm up to 235°C (455°F)
14 min
8 min
8 min
--
Cold start warm up to 300°C (554°F)
35 min
13 min
14 min
--
Max temp difference between two adjacent
zones
280°C**
(536°F)
90°C**
(194°F)
90°C**
(194°F)
270°C**
(518°F)
Blower rpm
2 x 1850
2 x 1850
2 x 1850
2 x 2600
Option
Value
Specification
Signal tower
Colours
3
Audio signal
optional
Slow speed option
Order number
RO300FC-15
Conveyor speed range
10-200 -7.9
Flying thermocouples
Order number
RO300FC-1
Length
5 m (16.4 ft)
Quantity
2
Temperature display
Directly on the on the integrated LCD Panel or
optional importable into RO-Soft
RO-Soft profiling software
Order number
RO300FC-SOFT-2
Measure channels
5 (2 for thermocouples, 3 for zone temperature)
Recording time
up to 180 hours
Data export format
.pdf (pdf writer necessary on the PC), .csv (for excel import)
Delivered with
RS232 connection cable, SUB-D Adapter 25pin-9pin
Data Connection
RS232
PC requirements
Pentium 3 or better
System requirements
Option RO300FC-1 (Flying Thermocouples)
Exhaust incl. ventilator
Order number
RO300FC-VNT
Scope of delivery
Covered exhaust fan with connection pipes to the two
exhausting nozzles, Power cable connected to the oven
Technical details
500m3/h (300cfm) air exhausting, 230V 50/60Hz
Customers side installation
1 Pipe or tube to the outside or to air cleaning equipment
Fire proof and temperature resistant up to 70°C (158°F)
Exhaust Tubes
(without Ventilator)
Scope of delivery
Connection pipes to the two exhausting nozzles.
Customer side installation
Exhausting system with 1 Pipe or tube
Fire proof and temperature resistant up to 70°C (158°F)
Slide out unit
Order number
Meshbelt: RO300FC-4, pin conveyor: RO300FC-4C
Sliding angle
adjustable with screws
Transport width
Meshbelt: 400 mm (15.8"),Pin conveyor:10- -
Specifications
Option
Value
Specification
PCB Counter
Sensor type
Optical polarized
Order numbers:
Mesh belt RO300FC-3B
Chain conveyor) RO300FC-3
ling System for Chain conveyor
Order number
RO300FC-10
Located
Directly on the two chain rails at the entrance side
Type of used oil
High temperature oil up to 300°C (572°F)
Oiling cycle
Daily to weekly (depending to operation time)
Oil consumption
Depends from the oiling cycles
SMEMA Interface
Order number
RO300FC-13
Sensor
one at entrance and one at exit side
Sensor type
Optical polarized
Functions by side
Board counter
Scope of delivery
SMEMA connectors at entrance and exit side of the oven, one SMEMA cable, two
sensors
3 color signal tower
Order number
Light colors
Red, yellow, green
Standard with SMEMA
interface
No, but recommended
PC monitor and keyboard
support arm
Order no.
RO300FC-7
Located
At the entrance side of the oven, easy to handle from the operators place and
moveable to the backside if not needed.
Packing information
Box (LxWxH)
2170x1040x955 mm (7.12x3.41x3.13 ft)
Shipping weight with
meshbelt (Airfreight)
340 kg ( 750 lb)
Shipping weight with
pinchain conveyor
(Airfreight)