03254734-01-01 DEK TQ Vitesco Tech Spec.pdf - 第7页
7 DEK TQ Vitesco Machine Sta ndard Confi guration Technical Data Services Specificati on Mains Supply P ower Supply V oltage 11 0 Volts to 2 3 0 Volt s ±10%. Sing le phase 50/60 Hz Maximum Curr ent at 110V 15.2 Amps with…

6
DEK TQ Vitesco
Machine Standard configuration
Technical Data
Vision
Specification
Vision System
SFF
Fiducials
3
Fiducial Types
Synthetic fiducial library or unique pattern recognition
Fiducial Size
0.3mm to 3mm
Fiducial Locations
Anywhere on substrate
Camera Lighting
Software controlled programmable LED lighting
Chase
Specification
Stencil Frame Sizes
29” x 29” / 23” x 29” / 23” x 23” / 650mm x 550mm /
600mm x 550mm
Stencil Frame Thickness
40mm to 10mm (adapter required below 25mm)
Image Position
Front
Centre
Operating Environment*
Specification
Temperature
10° to 35°C (50° to 95°F)
Humidity
30% to 70% relative humidity (non-condensing)
Altitude
Maximum 2,000 metres (6,500 feet)
Location
Internal only, not suitable for wet locations
*as described in the IPC Standard J-STD-001G-Reqirements for Soldered Electrical and Electronic
Assemblies Section 4 with respect to the following:
• Facilities - Cleanliness and ambient environments in all work areas be maintained at levels that
prevent contamination or deterioration of tools, materials, and surfaces to be soldered or
conformally coated. Eating, drinking, smoking, including use of e-cigarettes, and/or use of
tobacco products be prohibited in the work area.
• Environmental Controls - The soldering facility (controlled work area) be enclosed, temperature
and humidity controlled, and maintained at a positive pressure.
• Controlled Work Area (CWA) For the purpose of this statement, a Controlled Work Area
(CWA) is defined as an enclosed assembly / processing area maintained to a high degree of
shop cleanliness, environmental control, and foreign object debris (FOD) mitigation, either by
process or procedure, to limit the entry of contamination.

7
DEK TQ Vitesco
Machine Standard Configuration
Technical Data
Services
Specification
Mains Supply Power Supply Voltage
110 Volts to 230 Volts ±10%. Single phase 50/60 Hz
Maximum Current at 110V
15.2 Amps with internal vacuum pump
6.6 Amps without internal vacuum pump
Maximum Current at 230V
9.2 Amps with internal vacuum pump
4.6 Amps without internal vacuum pump
Over Current Protection at 110V
The following external circuit breaker is required to be
fitted in line with the machine supply:
With internal vacuum pump -16 Amps
Without internal vacuum pump – 8 Amps
Over Current Protection at 230V
The following external circuit breaker is required to be
fitted in line with the machine supply:
With internal vacuum pump -10 Amps
Without internal vacuum pump – 6 Amps
Compressed Air Supply
To ISO 8573.1 Standard Quality Class 2.3.3
Pressure 5 bar to 8 bar
General usage 5 litres / minute at 5 bar to 8 bar
Maximum usage 226 litres/minute at 6 bar
Shipping Information
Specification
Approximate Weight
1110kg boxed (dependent upon configured options
selected with machine)
905kg unboxed (dependent upon configured options
selected with machine)
Approximate Dimensions
1300mm x 1000mm x 1600mm High
Certification
Specification
CE
2006/42/EC
2014/30/EU
2011/65/EU
Subsequent amendments
Acoustic Noise Level
Less than 70dB 2003/1/EC
Certified wet print accuracy
Accuracy Verification (AVS)

8
DEK TQ Vitesco
Machine Standard Configuration
Technical Data
Process
Standard
Print Method
Paste Dispenser or Solder Jar Dispenser
Dual Access Cover for parallel paste replenishment
Paste Roll Height Monitor (PRHM)
Data Capture
Standard
Software & Communications
Verification
Traceability
SMART Factory Integration
Standard
Software & Communications
IPC-Hermes -9852
Closed-loop-to-SPI