BPH514R (Light Receiving Side) BPH514T (Light Emitting Side) 4.2.5 [Pallet Chuck Claw Connection Check] Sensor This sensor works to prevent the machine from being operated with the pallet chuck claw being connected incor…

100%1 / 223
4.2.4 [Rack Shutter (Traverse Side) Check] Sensors
These sensors work to check if the rack shutter is opened or closed.
Sensor Name Symbol Countermeasures
[Right Rack Shutter
(Traverse Side) Opening
Check] Sensor
[Right Rack Shutter
(Traverse Side) Closing
Check] Sensor
[Left Rack Shutter
(Traverse Side) Opening
Check] Sensor
[Left Rack Shutter
(Traverse Side) Closing
Check] Sensor
BPS501
BPS503
BPS504
BPS502
Fig. X25
Table X12
An error occurs when it cannot be confirmed that the
rack shutter is being opened during opening opera-
tion.
An error occurs when it cannot be confirmed that the
rack shutter is being closed during closing operation.
BPS501
BPS502
BPS503
BPS504
4.2 Protective Sensors
0204-002 30 AHI01EGP
BPH514R
(Light Receiving Side)
BPH514T
(Light Emitting Side)
4.2.5 [Pallet Chuck Claw Connection Check] Sensor
This sensor works to prevent the machine from being operated with the
pallet chuck claw being connected incorrectly with the pallet.
Sensor Name Symbol Countermeasures
[Pallet Chuck Claw
Connection Check] Sensor
Fig. X26
Table X13
This sensor is used to detect if a pallet exists or not
during drawout and return operations.
An error occurs when the sensor cannot detect a pallet
during clutch engagement (for drawout), drawout, and
return operations.
BPH514
4.2 Protective Sensors
0311-002 31 AHI01EGP
BPH518T
(Light Emitting Side)
BPH518R
(Light Receiving Side)
BPH517R
(Light Receiving Side)
BPH517T
(Light Emitting Side)
BPH522T
(Light Emitting Side)
BPH522R
(Light Receiving Side)
4.2.6 [Mispicked Component Detection] Sensors
These sensors work to detect an ejected component on the tray pallet
and a mispicked component.
Sensor Name Symbol Countermeasures
[Lower Mispicked
Component Detection]
Sensor
[Upper Mispicked
Component Detection]
Sensor
[High Mispicked
Component Detection]
Sensor
Fig. X27
Table X14
BPH517
BPH518
BPH522
4.2 Protective Sensors
0311-002 32 AHI01EGP
When one of the left sensors has detected an error, the
following measures are taken.
When a mispicked component is detected during op-
eration, the traverse shaft decelerates and stops.