ACT - Accuracy Check Tool.pdf - 第144页
ACT with SSW 7xx / User Manual 07/2017 Edition 36 4.1.2.2 Specifying ACT Programs i n Stand Alone Mode Due to the above - des cribed permane nt storage of the placement program s on the station, a o nce - defined program…

ACT with SSW 7xx / User Manual 07/2017 Edition
35
► Enable the Store Recipe permanently on Station check box.
Figure 4-2: Configuration – Columns
► When specifying the program, enable the check box in the Permanent an der Station
speichern (Store permanently on Station) column in the list of SIPLACE Pro Line Control
GUI.
Figure 4-3: Storing specification permanently
Programs specified in this way keep stored on the station until they are explicitly deleted.

ACT with SSW 7xx / User Manual 07/2017 Edition
36
4.1.2.2 Specifying ACT Programs in Stand Alone Mode
Due to the above-described permanent storage of the placement programs on the station, a once-
defined program can be repeated at any time in stand-alone mode at the station, without having to
re-specify via SIPLACE Pro.
You are in the Stand alone mode (1).
Figure 4-4: Stand alone mode
► Select a new board (placement program) from the stored list on the station under New board
(2).
The boards stored on the station are listed in the following window.
Figure 4-5: Permanent specification
The permanently stored boards are marked with a Padlock symbol (1).
► Mark the corresponding line.
► Either specify the board on one lane (2) or on both lanes simultaneously (3).

ACT with SSW 7xx / User Manual 07/2017 Edition
37
4.1.2.3 Accessibility Problems for Various Machine / Head Configurations
SIPLACE SX4 and DX4 machines:
NOTICE
In order to access the fiducials, the ACT measuring plate has to be placed rotated by
180° in SIPLACE SX4 and DX4 machines.
Thus, if an ACT placement program is defined for a SIPLACE SX4 or DX4 machine, the orientation
(position) of the board has to be adapted to 180° in the created recipe.
Figure 4-6: Rotating board orientation by 180° on SX4, DX4
If this adaption of the board orientation is not performed, the following error message (example) is
already displayed on the SIPLACE Pro Line Control GUI during specification:
Figure 4-7: Example: Error message due to unavailable ink spots
NOTICE
Due to the problems of accessing the fiducials described above, please observe:
If the ACT has to be measured on a machine of the SX-, DX-, or X-series, in front of
which one or more SIPLACE SX4- or DX4-stations are arranged in a line, the Pass-
through function has to be activated on all machines in front of the measuring machine
that require another board orientation (0°/180°).