00191663.pdf - 第28页

DCA Option Retrofit Instructions 80F5 05/99 issue 28

100%1 / 30
Retrofit Instructions 80F5 DCA Option
05/99 issue 12 Fixing the cover for the FC camera
27
In the ’Machine options at location’ box, the ’BeZ~RV_Cam_13_32x32’ line will be highlighted
in black.
È Click on the ’Delete’ button in the ’Actions’ box.
È In the ’Components at location’ box, click on the camera highlighted in black again.
The camera entry will be deleted.
11.2.2 Configuring the new camera
È Click on the ’Allocate’ button in the ’Actions’ box.
È Double-click on the ’RV_Cam_14_15x15’ button.
The camera will appear in the ’Placeable machine options’ box.
È Click on the camera in the ’Configurable components’ box.
The new FC camera is now configured.
11.2.3 Saving the new configuration
È Click on ’File’ from the desktop menu bar, followed by ’Data Manager’.
The main Data Manager window will open.
È Double-click on the ’Master data’ icon.
The Master data window will open.
È Open the ’Stations’ directory.
È Select the station.
È In the ’Double-click’ box, double-click on the ’Compiler’ button.
This will start the conversion program for the station. After a few seconds, a message will ap-
pear telling you that the file has been converted.
È Click on ’OK’ in the dialog box.
12 Fixing the cover for the FC camera
È Fix the cover for the FC camera. (The fixing points are shown in Fig. 7 - 1).
12
DCA Option Retrofit Instructions 80F5
05/99 issue
28