00195440-05-SG_D-Series_FSE-EN.pdf - 第264页
15 SIPLACE Measuring Tools 15.3 Adjustment Aid for Changeover Table [00120040-01] 15.1.1 Sc ope of Delivery 264 Student Guide SIPLACE D-Series (FSE) 15.3 1 5 . 3 A d ju s t m e n t A id f o r C h a n g e o v e r T a b le…

15 SIPLACE Measuring Tools
15.1.1 Scope of Delivery 15.2 SIPLACE Diagnosis Adapter A364 [03051220-01]
Student Guide SIPLACE D-Series (FSE) 263
15.1.1
15.1.1 Scope of Delivery
Scope of Delivery
The SIPLACE axis tester package [03002801-01] contains the following components:
▪ SIPLACE axis tester [03000761-01]
▪ Test cable A361 ... A363 (length 150 cm) with 37 pin connector and 37 pin socket for connection of
axis control units from S2x, F4/F5 and HS machines [03002803-01]
▪ CAN Bus cable [00349679-03]
▪ RS232-C cable [03002804-01]
▪ Manual for axis tester [00193370-01]
15.2
15.2 SIPLACE Diagnosis Adapter A364 [03051220-01]
SIPLACE Diagnosis Adapter A364 [03051220-01]
Application:
The adapter card is used to check the A364 axis card dynamics.
The A364 axis card is equipped with two processors (module 1 and module 2) i.e. one processor controls
two axes.
NOTICE
This adapter is designed for all machines with A364 and as an adapter for the CAN test box
with force measuring tool.
Adapter card for A364
Legend
Module 1: Axis 1/2
Module 2: Axis 3/4
1. Bootstrap mode: m1 = module1 / m2 = module2
2. Diagnosis – connector X6
3. Connection X3 SIPLACE AxisTester
4. Connection X2 Axis test box
5. Connection X1 to A364
6. Switches:
7. Diagnosis – 7 segment display
8. CAN bus connector (Sub-D)
9. BNC sockets:
10. Reset both processors

15 SIPLACE Measuring Tools
15.3 Adjustment Aid for Changeover Table [00120040-01] 15.1.1 Scope of Delivery
264 Student Guide SIPLACE D-Series (FSE)
15.3
15.3 Adjustment Aid for Changeover Table [00120040-01]
Adjustment Aid for Changeover Table [00120040-01]
This setting gauge is not provided in the SIPLACE Pro computer delivery package and needs to be or-
dered separately for a new line.
▪ Application:
The adjustment aid is needed for calibration of the
changeover table.
It is only needed (or can only be used) for SIPLACE
S tables.
CAUTION! Never use more than one adjust-
ment aid for pickup position calibration on one changeo-
ver table.Exception: You may occasionally need to use
another adjustment aid for a different side of the machine
or line.

16 Annex (FSE)
16.1 Overview of Calibration Tools
Student Guide SIPLACE D-Series (FSE) 265
16
16 Annex (FSE)
Annex (FSE)
16.1
16.1 Overview of Calibration Tools
Overview of Calibration Tools
16.2
16.2 Overview of Settings and Calibration Work
Overview of Settings and Calibration Work
The settings and calibration work have been sorted in the same order and assigned to the service work
listed.
adjust - and
calibration tools
adjust and
calibration jobs
Machine types
(without S15/F3)
Digital Manometer 00311487 -01
Digital Manometer with analouge-cable for
S15/F3 00313523 -01
Track signal tester for S/F 00322510-02
Adapter cable track signal tester f. F5HM/S27HM
00360395-01
Track signal tester for HS/HF 00343785-01
glueing gauge for incremental scale exchange.
gaugge for 0.8mm plate distance (Trace out
magnet 00358519-01)
Belt tension meter TSM 00326015-01
Axis test box Vers.6 00303430-06 alternatively to
SAT
SIPLACE Axis Tester SAT 03002801-01
Adapter board for A364 Axis controller
03051220.xx
RC-Filter 02102858-01
0,2mm distance gauge 00325445-01 from gauge
set 00327005-01
Star-0-point.gauge 00326164-01 from gauge set
00327005-01
power supply for Star mounting DLM-heads
00353277-01
1.0 mm pin (replace 1.3mm pin from gauge set
00327005-01)
1,4; 1,5; 1,6mm pins from gauge set 00327005-
01
gauge Z-axis stop top 00331308-01
Test connector safety loop coplan ILD 2000
00337304-01
calibration tool coplan 00315365-03
calibration tool Vision Version II (clear) 00316308
-
03
calibration tool Vision Version 3 (for hf / white)
03010565-01
calibration nozzle D-zero-point-corr. Twin
03008862-02
I/O-Tester for SXX/FX 00321960-01
wiring test adapter 14 pole 02304826-01
wiring test adapter 34 pole 02304827-01
adjust gauge for clamping new TSP
S27/HS60/HF specific
adjust gauge for clamping sensor new TSP
S27/HS60/HF specific
gauge f. Z-Axis bearing C&P (* special trained
staff only) 335346
gauge for ball race(* special trained staff only)
333625
Mapping plate S/F/HS single TSP 00325743-01
Mapping plate S/F/HS DoubleTSP 00325698-01
Mapping plate HF single or double TSP 00355064-
01
Fine calibration set 00343710-01
exchange vacuum distrib./Star/
air kiss unit. All
S15
F3
exchange incremental encoder
gantry
All
S/F
F5HM/S
27HM
HF/
HS
exchange incremental scale
gantry
All
S/F
F5HM/S
27HM
HF/
HS
Exchange incremental scale
gantry X-Axis HF / X
HF/
HS
without
gauge
Exchange incremental scale
gantry X-Axis D1 / D2
HF/
HS
at
mom.
without
gauge
Exchange incremental scale
gantry Y-Axis HS / D4
HF/
HS
HS-
ver s .
Exchange incremental scale
gantry Y-Axis HF / X
HF/
HS
HF-
ver s .
Exchange incremental scale
gantry Y-Axis D1/D2
HF/
HS
D1-
ver s .
replacement Y-Magnets
HS/HF/X/D series
all with
lin. drive
exchange 'head board' C&P
head
exchange 'conversion board
large axis'
exchange incremental encoder
DP axis All All
exchange lightbarrier bottom
C&P head All
exchange placement star All
All with
DLM x
exchange Z-motor All All All All
exchange Z-belt All All All All All
exchange Z-top stop All
exchange drive belt /- motor All All All All
exchange coplanarity module All F All F
exchange PCB camera X/ D
All
w ithout
. HF
exchange C&P-placement
head X/ D
All
w ithout
. HF
exchange component cameras
All
w ithout
. HF
exchange segment Twin-head X/D HF HF
Display I/O-States of the I/O-
Boards
All
S/F
wiring test ribbon cable All All
exchange ballrace only spec.
trained staff All All
Mapping
S/F/
HS
S/F/
HS
Mapping
HF
Fine calibration
All
All S/F
w ithout
S27/F5
HM
The measuring in 1.3 mm is replaced by a 1.1 mm version The Allen key 14 mm 00373927-01 is t o adjust machine SMEMA height The Allen key 19 mm 00373928-01 is to fix MA-feets