00194923-01_OIS_DB.pdf - 第22页

Schnittstellenbeschreibung OIS Datenbank Version 4.1 Interface Description OIS Database Version 4.1 22 von 47 2085 No. of pins: no result 2086 No. of pins: no result (Corner) 2087 No. of pins: no result (Lead) 2088 Colin…

100%1 / 47
OIS Datenbank Version 4.1 Schnittstellenbeschreibung
OIS Database Version 4.1 Interface Description
21 von 47
2045 Component angle outside tolerance (Lead)
2046 Component angle outside tolerance (Grid)
2047 Component angle outside tolerance (Ball)
2048 Position: evaluation not possible
2049 Position: evaluation not possible (Size)
2050 Position: evaluation not possible (Row)
2051 Position: evaluation not possible (Corner)
2052 Position: evaluation not possible (Lead)
2053 Position: evaluation not possible (Grid)
2054 Position: evaluation not possible (Ball)
2055 Dimension: evaluation not possible
2056 Dimension: evaluation not possible (Size)
2057 Dimension: evaluation not possible (Row)
2058 Dimension: evaluation not possible (Corner)
2059 Dimension: evaluation not possible (Lead)
2060 Dimension: evaluation not possible (Grid)
2061 Dimension: evaluation not possible (Ball)
2062 No. of pins: evaluation not possible
2063 No. of pins: evaluation not possible (Corner)
2064 No. of pins: evaluation not possible (Lead)
2065 Colinearity: evaluation not possible
2066 Colinearity: evaluation not possible (Corner)
2067 Colinearity: evaluation not possible (Lead)
2068 Spacing: evaluation not possible
2069 Spacing: evaluation not possible (Corner)
2070 Spacing: evaluation not possible (Lead)
2071 Position: no result
2072 Position: no result (Size)
2073 Position: no result (Row)
2074 Position: no result (Corner)
2075 Position: no result (Lead)
2076 Position: no result (Grid)
2077 Position: no result (Ball)
2078 Dimension: no result
2079 Dimension: no result (Size)
2080 Dimension: no result (Row)
2081 Dimension: no result (Corner)
2082 Dimension: no result (Lead)
2083 Dimension: no result (Grid)
2084 Dimension: no result (Ball)
Schnittstellenbeschreibung OIS Datenbank Version 4.1
Interface Description OIS Database Version 4.1
22 von 47
2085 No. of pins: no result
2086 No. of pins: no result (Corner)
2087 No. of pins: no result (Lead)
2088 Colinearity: no result
2089 Colinearity: no result (Corner)
2090 Colinearity: no result (Lead)
2091 Spacing: no result
2092 Spacing: no result (Corner)
2093 Spacing: no result (Lead)
2094 Position: component outside feed tolerance
2095 Position: component outside feed tolerance (Size)
2096 Position: component outside feed tolerance (Row)
2097 Position: component outside feed tolerance (Corner)
2098 Position: component outside feed tolerance (Lead)
2099 Position: component outside feed tolerance (Grid)
2100 Position: component outside feed tolerance (Ball)
2101 Dimension: component outside feed tolerance
2102 Dimension: component outside feed tolerance (Size)
2103 Dimension: component outside feed tolerance (Row)
2104 Dimension: component outside feed tolerance (Corner)
2105 Dimension: component outside feed tolerance (Lead)
2106 Dimension: component outside feed tolerance (Grid)
2107 Dimension: component outside feed tolerance (Ball)
2108 No. of pins: component outside feed tolerance. Sequential error
2109 No. of pins: component outside feed tolerance (Corner)
2110 No. of pins: component outside feed tolerance (Lead)
2111 Colinearity: component outside feed tolerance. Sequential error
2112 Colinearity: component outside feed tolerance (Corner)
2113 Colinearity: component outside feed tolerance (Lead)
2114 Spacing: component outside feed tolerance. Sequential error
2115 Spacing: component outside feed tolerance (Corner)
2116 Pitch: Component outside feeding tolerance (Lead)
2277 The difference between open and closed vacuum values is too small
2424 Coplanarity: Bad component, to be returned
2451 Coplanarity: Component cannot be measured (excessive offset in lead direction)
2452 RV-head: Segment not airtight after placement
2453 IC-head: Segment not airtight after placement
2454 Nozzle contaminated or worn out
2455 Vacuum value of segment too low with valve closed
2516 Warning: Nozzle is slightly soiled
OIS Datenbank Version 4.1 Schnittstellenbeschreibung
OIS Database Version 4.1 Interface Description
23 von 47
3475 Difference in vacuum too great between placement and pick-up
3513 Vision system: Flipped component detected
3553 Component not on nozzle prior to dipping
3570 Component on the nozzle before pickup pr nozzle dirty
3573 Nozzle dirty or obstruction during pickup
13005 Coplanarity module: Component faulty
15265 Cover foil on tape feeder damaged
15266 Cover foil not removed from tape feeder
17410 Warning RV head: Segment not airtight after placement
18109 Nozzle could not be identified by component sensor
18132 Warning: No component available for placement
18133 Warning: Nozzle is soiled
18134 Warning: Measured component height too large
18135 Warning: Measured component height too small
18136 Nozzle worn
18137 Track empty error detected by component sensor
18139 Nozzle soiled before pick-up
18509 Vacuum not achieved (no component on the nozzle)
18510 Vacuum not achieved (component not located securely on the nozzle)
18517 The difference between open and closed vacuum values is too small
18554 Component not at nozzle after pick-up
18555 Component not on nozzle prior to placement
18557 Nozzle not empty prior to pick-up
18558 Nozzle not empty after placement
18560 Error in feeder on pick-up
18565 Component not at nozzle after pick-up
18566 Component not at nozzle before placement
18567 Component not on nozzle during dipping
18570 Component not on nozzle prior to dipping
18916 Component cannot be picked up with the selected head type
18921 (Bauelement wird abgeholt, bevor die Abholposition erreicht wird)
19112 Component not seated on nozzle correctly on pickup
21017 Component picked up at wrong angle
21424 Component description for measurement with SIPLACE Vision incomplete
21802 Component outside feed tolerance
21803 Component rotation angle outside tolerance
21804 Measured offset in X and Y outside presentation tolerance
21805 Measured offset in X outside presentation tolerance
21806 Measured offset in Y outside presentation tolerance
21811 Position cannot be determined