4OM-1751
1-56
5.2 Method of detaching vacuum nozzle
Store the nozzle in the nozzle stocker (housing) through window
navigations and take out the nozzle stocker (housing).
Notice
(a) Do not take out a nozzle from the head by hand. Otherwise, the
nozzle does not conform to the nozzle data.
(b) When the ultrasonic cleaning operation is to be performed
underwater, remove the nozzle lter.
Do not use anything other than water for the cleaning.
(c) Demagnetize the vacuum nozzle after the detachment.
Keep the head section free of any magnetic eld.
As an example,
Do not bring a magnet close to the head section.
Do not bring any demagnetizer to the head section.
Demagnetize the vacuum nozzle each unit.
Reference
Refer to "5. Nozzle Change Window" in "Chapter 6 (Vol. 2)" for the
procedure of nozzle storage.
1304-001
5.2 Method of detaching vacuum nozzle
4OM-1751
1-571304-001
5.3 Nozzle Filter Removal Procedure


Filter Removing Jig
Vacuum Nozzle
Push
Pushing out the nozzle filter.
F4A48
Note

5.3 Nozzle Filter Removal Procedure
4OM-1751
1-58
5.4 Method of Blow air
Remove dust and dirt etc.

Clean the tapered area of the vacuum nozzle with a lens cleaning cloth.
Notice
Use clean, dry, and non-lubricated air for blow air.
F4A49
NOTICE
Blow air to the head when blow air to the nozzle.
There is a possibility that the clamp jaw breaks when
the air blow is done from the direction of the clamp
jaw to the nozzle.
1304-001
5.4 Method of Blow air