4M-1751-005w_G5S.pdf - 第186页
Error ID Error Name, Description, Cause, and Remedy 42b602 T ransfer check Going down in the backup base(R) was not completed within the predetermined time. ----- 42b603 T ransfer check Going down in the backup base(AL) …

Error ID Error Name, Description, Cause, and Remedy
42b202 Time-out of Shuttle Conveyor in Output side
Time-out is occurred during Output Mode for Output Machine.
PCB is stopped between Conveyors. Check out PCB position.
1. Please conrm whether Transit position from shuttle conveyor is proper.
2. Please conrm whether Conveyor Width is t.
42b203 Time-out of Shuttle Conveyor in Output side
Time-out is occurred while Transfer position from Inner Machine is being moved.
Please conrm whether there is no error in Unit, no interference or not.
42b204 Time-out of Shuttle Conveyor in Output side
Time-out is occurred while Delivery Position is being moved to Output Machine.
Please conrm whether there is no error in Unit, no interference or not.
42b301 Shuttle Conveyor Error in Output side.
Error is made while Shuttle Conveyor is working.
-----
42b401 Transfer check
PCB is detected on the conveyor. Please remove it.
-----
42b501 Transfer check
Going down in PCB stopper(L) was not completed within the predetermined time.
-----
42b502 Transfer check
Going down in PCB stopper(R) was not completed within the predetermined time.
-----
42b503 Transfer check
Going down in PCB stopper(AL) was not completed within the predetermined
time.
-----
42b504 Transfer check
Going down in PCB stopper(AR) was not completed within the predetermined
time.
-----
42b505 Transfer check
Going down in PCB stopper(BL) was not completed within the predetermined
time.
-----
42b506 Transfer check
Going down in PCB stopper(BR) was not completed within the predetermined
time.
-----
42b601 Transfer check
Going down in the backup base(L) was not completed within the predetermined
time.
-----
3.3 Conveyor
4OM-1751
3-541701-005

Error ID Error Name, Description, Cause, and Remedy
42b602 Transfer check
Going down in the backup base(R) was not completed within the predetermined
time.
-----
42b603 Transfer check
Going down in the backup base(AL) was not completed within the predetermined
time.
-----
42b604 Transfer check
Going down in the backup base(AR) was not completed within the predetermined
time.
-----
42b605 Transfer check
Going down in the backup base(BL) was not completed within the predetermined
time.
-----
42b606 Transfer check
Going down in the backup base(BR) was not completed within the predetermined
time.
-----
T4C5
3.3 Conveyor
4OM-1751
3-551701-005

3.4 Tray Feeder (Block1)
Error ID Error Name, Description, Cause, and Remedy
430201 Tray Motor Error(Block1)
Elevator abnormal stop
-----
430202 Tray Motor Error(Block1)
Elevator abnormal stop
-----
430203 Tray Motor Error(Block1)
Traverse abnormal stop
-----
430301 Tray Rack Shutter open/close error (Block1)
The Rack Shutter did not open in prescribed time.
-----
430302 Tray Rack Shutter open/close error (Block1)
The Rack Shutter did not close in prescribed time.
Please conrm whether the palette is not caught in the rack shutter.
430401 Tray Pallet Chuck open/close error (Block1)
The Pallet Chuck did not open in prescribed time.
-----
430402 Tray Pallet Chuck open/close error (Block1)
The Pallet Chuck did not close in prescribed time.
-----
431001 Tray Supply Operation Error (Block1)
-----
431002 Tray Supply Operation Error (Block1)
Tray steps No. disagreement of draw out(return operation)
-----
431003 Tray Supply Operation Error (Block1)
Tray steps No. disagreement of draw out(return operation)
-----
431004 Tray Supply Operation Error (Block1)
The operation mode is illegal. (system)
-----
431005 Tray Supply Operation Error (Block1)
The position of TV axis is irregular
-----
431006 Tray Supply Operation Error (Block1)
Magazine classication disagreement
Please carry out the check of ten steps of magazines, and 15-step type.
431101 Tray Pallet Returning Error (Block1)
Elevator pre-check error
-----
3.4 Tray Feeder (Block1)
4OM-1751
3-561701-005