Accessories (continued)
Ratio Check Cap
In order to ensure correct A/B ratio, ratio checks
should be performed regularly with our new Ratio
Check Cap.
Night Cap
At night or on weekends, it is a good idea to seal your
system. After the static mixer is removed, a night cap
can be installed. This seals the system and makes
startup simpler.
P/N Description
7701184* Ratio Check Cap with retaining nut
7701181* Night Cap with retaining nut
*Use with 1:1 ratio manifolds only.
Ratio check
Night cap
Manifold Manifold
Series 400 Autovalve | Instructions / Parts Lists
13www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Troubleshooting
Problem Possible Cause Solution
No flow Manifold clogged Remove manifold and clean
Air pressure too low Requires 5.5bar (80psi) inlet pressure
Air valve damaged See Note 1 below
Valve fouled Disassemble (see Maintenance)
Valve leaks Front seals (13) not seated See Note 2 below
Front seals (13) damaged Replace seals
Valve drools Air trapped in manifold Review startup procedure
Off ratio A:B Metering pumps Check pumps
A & B back up into tie plate Seals (3) damaged Replace back lip seals (page4)
Material not mixing Mixer fouled Replace mixer
Off ratio A:B Take ratio check
Mixer leaks Manifold fouled Clean nose of manifold
Lip seals deteriorated Chemical attack See Maintenance
NOTE 1: Inspect air cartridge valve (103) in handle (90). The On-Off function of the valve is controlled by this cartridge valve
in the handle. The air cylinder requires air in the back to close and air in the front to open.
To inspect the cartridge valve, disconnect the two air lines on the air cylinder (1). When the trigger is depressed, air should
be flowing only through the back air line and not through the front air line. When the trigger (91) is released the air should
reverse.
NOTE 2: The front seals cold flow into the seat plate (8). With valve closed, maintain air pressure on air cylinder to break in
seals.
For Nordson EFD sales and service in over
40 countries, contact Nordson EFD or go to
www.nordsonefd.com.
Global
800-556-3484; +1-401-431-7000
info@nordsonefd.com
Europe
00800 7001 7001
infoefd.europe@nordsonefd.com
Asia
China: +86 (21) 3866 9006; china@nordsonefd.com
India: +91 80 4021 3600; india@nordsonefd.com
Japan: +81 03 5762 2760; japan@nordsonefd.com
Korea: +82-31-736-8321; korea@nordsonefd.com
SEAsia: +65 6796 9522; sin-mal@nordsonefd.com
Viton is a registered trademark of E.I. DuPont.
The Wave Design is a trademark of Nordson Corporation.
©2021 Nordson Corporation 7703863 v071221
Series 400 Autovalve | Instructions / Parts Lists