FUJI错误代码查询.pdf - 第168页

Remedy: Specify the X2 axis plus movement range in Proper data item 136.Max_Limit_Position_X2 for the FLT and 146.Max_Limit_Position_X2 for the FIP3. ------------------------------ Code: 11022914 Display: Used by: IP3 Ca…

100%1 / 5282
Display:
Used by: IP3
Cause: The carrier position Z1 position has not been specified even though carrier 1 is supposed to pick
parts from MFU1.
Remedy: Input the pulse count of the Z1 axis at the picking position of carrier 1. For the FLT, use
125.MFU1_Position_Z. For the FIP3, use 134.MFU1_Position_Z1.
------------------------------
Code: 1102290E
Display:
Used by: IP3
Cause: The carrier position Z2 position has not been specified even though carrier 2 is supposed to pick
parts from MFU2.
Remedy: Input the pulse count of the Z2 axis at the picking position of carrier 2. For the FLT, use
126.MFU2_Position_Z. For the FIP3, use 132.MFU2_Position_Z1.
------------------------------
Code: 1102290F
Display:
Used by: IP3
Cause: The nozzle change position has not been input for nozzle 1 even though that nozzle is to be
changed.
Remedy: Input the Z1 axis nozzle change position into Proper data
127.Nozzle_change_Pos.Z for the FLT and
136.Nozzle_change_Pos.Z1 for the FIP3.
------------------------------
Code: 11022910
Display:
Used by: IP3
Cause: The nozzle change position has not been input for nozzle 2 even though that nozzle is to be
changed.
Remedy: Input the Z1 axis nozzle change position into Proper data
137.Nozzle_change_Pos.Z2 for the FIP3.
------------------------------
Code: 11022911
Display:
Used by: IP3
Cause: The zero set position in the Q1 axis has not been input for nozzle 1.
Remedy: Input the Q1 axis zero set position into Proper data
128.Origin_Position_Q for the FLT and
138.Origin_Position_Q1 for the FIP3.
------------------------------
Code: 11022912
Display:
Used by: IP3
Cause: The zero set position in the Q2 axis has not been input.
Remedy: Input the Q2 axis zero set position into Proper data item
139.Origin_Position_Q2 for the FIP3.
------------------------------
Code: 11022913
Display:
Used by: IP3
Cause: The X2 axis plus movement range has not been specified.
第 167 页
Remedy: Specify the X2 axis plus movement range in Proper data item
136.Max_Limit_Position_X2 for the FLT and
146.Max_Limit_Position_X2 for the FIP3.
------------------------------
Code: 11022914
Display:
Used by: IP3
Cause: The Y axis plus movement range has not been specified.
Remedy: Specify the Y axis plus movement range in Proper data item
137.Max_Limit_Position_Y for the FLT and
147.Max_Limit_Position_Y for the FIP3.
------------------------------
Code: 11022915
Display:
Used by: IP3
Cause: The X1 axis plus movement range has not been specified.
Remedy: Specify the X1 axis plus movement range in Proper data item
143.Max_Limit_Position_X1 for the FLT and
152.Max_Limit_Position_X1 for the FIP3.
------------------------------
Code: 11022916
Display:
Used by: IP3
Cause: RCU line port setting is out of range.
Remedy: Input a value into Proper data's 158.RCU_line_Port setting.
------------------------------
Code: 11022917
Display:
Used by: IP3
Cause: The RCU line port was previously set to a different setting.
Remedy: Input a correct value into Proper data's 158.RCU_line_Port setting.
------------------------------
Code: 11022A00
Display: 11022A00
Used by: QP132
Cause: The RB servo communication port number is not specified.
Remedy: Specify the correct data for 110. Servo Control Port No. in Proper data. When connecting to the
second VM 1440 board, channel 1 is 17, 2 is 18, etc (17 is input when shipped)
------------------------------
Code: 11022A01
Display: 11022A01
Used by: QP132
Cause: The offset value between boards was not input for operation with multiple boards in one pallet.
Remedy: Specify the correct data for 125. PCB Setup tolerance in Proper data.
------------------------------
Code: 11022A02
Display: 11022A02
Used by: QP132
Cause: The program origin x coordinate for mark reading was not input.
Remedy: Specify the correct data for 141. Mark Read Position MXC in Proper data.
------------------------------
第 168 页
Code: 11022A03
Display: 11022A03
Used by: QP132
Cause: The program origin y coordinate for mark reading was not input.
Remedy: Specify the correct data for 142. Mark Read Position MYC in Proper data.
------------------------------
Code: 11022A04
Display: 11022A04
Used by: QP132
Cause: The coordinates of the F-axis origin for the feeder check were not input.
Remedy: Specify the correct data for 122. Feeder Check Origin F0 in Proper data.
------------------------------
Code: 11022A05
Display: 11022A05
Used by: QP132
Cause: The coordinates of the SS-axis origin were not input.
Remedy: Specify the correct data for 143. Step Slide Origin SS0 in Proper data.
------------------------------
Code: 11022A06
Display: 11022A06
Used by: QP132
Cause: The coordinates of the PI-axis origin were not input.
Remedy: Specify the correct data for 124. PCB Setup Position PI in Proper data.
------------------------------
Code: 11022A07
Display: 11022A07
Used by: QP132
Cause: The coordinates of the PO-axis origin were not input.
Remedy: Specify the correct data for 125. PCB Unload Position PO in Proper data.
------------------------------
Code: 11022A08
Display: 11022A08
Used by: QP132
Cause: The pulse count for the MX-axis minus direction limit was not set.
Remedy: Specify the correct data for 168. Min Limit Position MX in Proper data.
------------------------------
Code: 11022A09
Display: 11022A09
Used by: QP132
Cause: The pulse count for the MY-axis plus direction limit was not set.
Remedy: Specify the correct data for 163. Max Limit Position MY in Proper data.
------------------------------
Code: 11022A0A
Display: 11022A0A
Used by: QP132
Cause: The pulse count for the SS-axis plus direction limit was not set.
Remedy: Specify the correct data for 164. Max Limit Position SS in Proper data.
------------------------------
Code: 11022A0B
Display: 11022A0B
Used by: QP132
第 169 页