Cause: The pulse count for the PI-axis plus direction limit was not set. Remedy: Specify the correct data for 143. Max Limit Position PI in Proper data. ------------------------------ Code: 11022A0C Display: 11022A0C Use…
Code: 11022A03
Display: 11022A03
Used by: QP132
Cause: The program origin y coordinate for mark reading was not input.
Remedy: Specify the correct data for 142. Mark Read Position MYC in Proper data.
------------------------------
Code: 11022A04
Display: 11022A04
Used by: QP132
Cause: The coordinates of the F-axis origin for the feeder check were not input.
Remedy: Specify the correct data for 122. Feeder Check Origin F0 in Proper data.
------------------------------
Code: 11022A05
Display: 11022A05
Used by: QP132
Cause: The coordinates of the SS-axis origin were not input.
Remedy: Specify the correct data for 143. Step Slide Origin SS0 in Proper data.
------------------------------
Code: 11022A06
Display: 11022A06
Used by: QP132
Cause: The coordinates of the PI-axis origin were not input.
Remedy: Specify the correct data for 124. PCB Setup Position PI in Proper data.
------------------------------
Code: 11022A07
Display: 11022A07
Used by: QP132
Cause: The coordinates of the PO-axis origin were not input.
Remedy: Specify the correct data for 125. PCB Unload Position PO in Proper data.
------------------------------
Code: 11022A08
Display: 11022A08
Used by: QP132
Cause: The pulse count for the MX-axis minus direction limit was not set.
Remedy: Specify the correct data for 168. Min Limit Position MX in Proper data.
------------------------------
Code: 11022A09
Display: 11022A09
Used by: QP132
Cause: The pulse count for the MY-axis plus direction limit was not set.
Remedy: Specify the correct data for 163. Max Limit Position MY in Proper data.
------------------------------
Code: 11022A0A
Display: 11022A0A
Used by: QP132
Cause: The pulse count for the SS-axis plus direction limit was not set.
Remedy: Specify the correct data for 164. Max Limit Position SS in Proper data.
------------------------------
Code: 11022A0B
Display: 11022A0B
Used by: QP132
第 169 页
Cause: The pulse count for the PI-axis plus direction limit was not set.
Remedy: Specify the correct data for 143. Max Limit Position PI in Proper data.
------------------------------
Code: 11022A0C
Display: 11022A0C
Used by: QP132
Cause: The pulse count for the PO-axis plus direction limit was not set.
Remedy: Specify the correct data for 166. Max Limit Position PO in Proper data.
------------------------------
Code: 11022A0D
Display: 11022A0D
Used by: QP132
Cause: The pulse count for the F-axis plus direction limit was not set.
Remedy: Specify the correct data for 145. Max Limit Position F in Proper data.
------------------------------
Code: 11022A0E
Display: 11022A0E
Used by:
Cause: The X-axis servo zero setting speed was not specified in PM Proper data.
Remedy: Confirm that the Proper data item 520: [PM] Zero Setup Speed X is set. If not, input correct data.
------------------------------
Code: 11022A0F
Display: 11022A0F
Used by:
Cause: The Y-axis servo zero setting speed was not specified in PM Proper data.
Remedy: Confirm that the Proper data item 521: [PM]Zero Setup Speed Y was set. If not, input correct
data.
------------------------------
Code: 11022A11
Display: 11022A11
Used by:
Cause: The Z-axis servo zero setting speed was not specified in PM Proper data.
Remedy: Confirm that the Proper data item 522: [PM] Zero Setup Speed Z was set. If not, input correct
data.
------------------------------
Code: 11022A12
Display: 11022A12
Used by:
Cause: The creep speed for X-axis servo zero setting was not specified in the common PM Proper data.
Remedy: Confirm that the Proper data item 524: [PM] Creep Speed X was set. If not, input correct data.
------------------------------
Code: 11022A13
Display: 11022A13
Used by:
Cause: The creep speed for Y-axis servo zero setting was not specified in the common PM Proper data.
Remedy: Confirm that the Proper data item 525: [PM] Creep Speed Y was set. If not, input correct data.
------------------------------
Code: 11022A15
Display: 11022A15
Used by:
Cause: The creep speed for Z-axis servo zero setting was not specified in the common PM Proper data.
第 170 页
Remedy: Confirm that the Proper data item 526: [PM] Creep Speed Z was set. If not, input correct data.
------------------------------
Code: 11022A16
Display: 11022A16
Used by:
Cause: One of the settings H_X, M_X, L_X for the X-axis movement speed was not specified in the
common PM Proper data.
Remedy: Confirm that the Proper data items 528: [PM] Move Speed H_X, 529: [PM] M_X, and 530: [PM]
Move speed L_X are set. If not, input correct data.
------------------------------
Code: 11022A17
Display: 11022A17
Used by:
Cause: One of the settings H_Y, M_Y, L_Y for the Y-axis movement speed was not specified in the
common PM Proper data.
Remedy: Confirm that the Proper data items 531: [PM] Move Speed H_Y, 532: [PM] M_Y, and 533: [PM]
Move speed L_Y are set. If not, input correct data.
------------------------------
Code: 11022A18
Display: 11022A18
Used by:
Cause: One of the settings H_Q, M_Q, L_Q for the Q-axis movement speed was not specified in the
common PM Proper data.
Remedy: Confirm that the Proper data items 537: [PM] Move Speed H_Q, 538: [PM] M_Q, and 539: [PM]
Move speed L_Q are set. If not, input correct data.
------------------------------
Code: 11022A19
Display: 11022A19
Used by:
Cause: One of the settings H_Z, M_Z, L_Z for the Z-axis movement speed was not specified in the
common PM Proper data.
Remedy: Confirm that the Proper data items 534: [PM] Move Speed H_Z, 535: [PM] M_Z, and 536: [PM]
Move speed L_Z are set. If not, input correct data.
------------------------------
Code: 11022A1A
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The transmitted Proper data indicates a different machine type.
Remedy: Use F4G to retransmit the Proper data for the machine in question.
------------------------------
Code: 11022A1B
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The specified PLM quantity is outside the valid range.
Remedy: Set a value from 1 to 6 for "The Number of PLM (QP2)" in the Proper data.
------------------------------
Code: 11022A1C
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: A value has not been set for the PLM servo counter output interval.
Remedy: Set a value of 1 or greater for the "Counter Output Interval (QP2)" parameter in the Proper data.