Retrofitting Instructions Feeder Fastening Attachment (Addition) for Component Tab le SIP LACE 80 S-20/F4/S-15/F3 Edition 05/98 Seite 5 DANGER O O O The m achines in the SIPLACE fam ily are powered by 3 x 400 V +/- 10%, …

100%1 / 20
Feeder Fastening Attachment for Component Table (Optional) SIPLACE 80 S-20/F4/S-15/F3 Retrofitting Instructions
Edition 05/98
Seite 4
1.5 Preconditions and Restrictions
Software: No prerequisites in the case of SIPLACE 80 S-20/F4/S-15/F3.
Hardware: Older model SIPLACE 80 S-15/F3 placers with flap opener
Feeder modules: Following feeder modules require mechanical work:
24/32 mm S Article No.: 141093-02
44 mm S II Article No.: 141094-02
72 mm S II Article No.: 141097-02
Vibratory stick feeder type II Article No.: 142025-01
Vibratory stick feeder type III Article No.: 142031-03
Vibratory stick feeder Article No.: 142031-04
Basement for bulk case Article No.: 142318-04
If feeder fastening attachments are retrofitted without the required mechanical work
on the following feeders, restrictions on the feeder locations will result.
24/32 mm S track 4/16/28/40/52/64/76/88/100/112
56 mm S track 1/13/25/37/49/61/73/85/97/109
72 mm S track !/19/37/55/73/91
2 Safety Instructions
Retrofitting Instructions Feeder Fastening Attachment (Addition) for Component Table SIPLACE 80 S-20/F4/S-15/F3
Edition 05/98
Seite 5
DANGER
O O O
The machines in the SIPLACE family are powered by 3 x 400 V +/- 10%, 50/60 Hz line voltage.
Portions of the system are therefore conducting dangerous electricity. This voltage is applied to specific
modules inside the machine even while the master switch is turned off!
Unprofessional handling of the machines or contact with portions there of conducting electricity may result in
death, serious injury or considerable material damage.
At all times, observe applicable accident prevention regulations and VDE codes / regulations of the society of
electrical engineers and the special safety regulations in your country. More stringent safety regulations to
VDE 0113 or the corresponding instructions in your country must be adhered to during all work in the
machine.
Only Siemens service engineers
are permitted to carry out these retrofit jobs.
Before starting the retrofitting, turn off the master switch and pull out the mains plug. Secure the machine to
prevent it from being restarted by unauthorized personnel.
2.1 Definitions
DANGER O O O
As used in these instructions, this means that death, serious injury or extensive material damage will occur if
the instructions regarding danger are not observed.
WARNING
O O
As used in these instructions, this means that death, serious injury or extensive material damage may occur if
the instructions in the warnings are not observed.
CAUTION
O
As used in these instructions, this means that minor injury or material damage may occur if the instructions in
the caution message are not observed.
NOTE
As used in these instructions, this means that particular attention is to be directed to important information
regarding the product or the specific part of the instructions.
Feeder Fastening Attachment for Component Table (Optional) SIPLACE 80 S-20/F4/S-15/F3 Retrofitting Instructions
Edition 05/98
Seite 6
3 Preparatory Steps
3.1 Preparatory Steps for SIPLACE 80 S-20/F4/S-15/F3
Turn the placers off at the master switched and pull out the mains plug.
Tear down the two component tables.
Disconnect the electrical connections of the two component tables.
Loosen the horizontal tensioners on the two component tables and move the tables out of the placer
3.2 Preparatory Steps for SIPLACE 80 F4/F3 with WPC
Turn the placer off at the master switch and pull out the mains plug.
Tear down the two component tables.
Disconnect the electrical connections of the two component tables and the WPC
Pull the WPC out of the placer.
Loosen the horizontal tensioners on the left-hand component table and move it out of the placer.
Loosen the two component table fastening screws on the right-hand side.
Lift the component table out of the placer and place on a suitable stable surface (e.g., lab cart).
WARNING
O O
You will require the assistance of a second person to lift the component table. It is heavy and the risk of
injury is high.