00194598-01.pdf - 第52页

2 Retrofit instructions: ceramic substrate centering for SIPLACE S -27 HM Ceramic substrate centering SIPLACE S -27 HM 12/2004 Edition 52 2.7 Adapting to th e size of the substrate The ceram ic subs trate ce ntering m us…

100%1 / 66
Ceramic substrate centering SIPLACE S-27 HM 2 Retrofit instructions: ceramic substrate centering for SIPLACE S-27 HM
12/2004 Edition
51
: If you wish to remove the travel limiters, insert the tool over the limiter and then pull the spring
up.
The travel limiter can then be pulled out at the side.
2
Make sure that the spring does not jump out. It must be lowered correctly back into a groove or
placed around the pins. 2
2
Please contact Siemens L&A Product Management if you need to place the PCBs right up to the
edge. 2
2.6 Set the response distance of the proximity switch
: Make sure that the active surface of the inductive proximity switch is set back 0.2 mm from the
stop surface of the carriage unit in the hole.
This prevents the proximity switch acting as a stop during the opening movement, and thus
being damaged.
: Correct the position of the proximity switch if necessary (grub screw, size 1 hexagon socket
spanner).
The proximity switch has an LED for checking the switching process.
2 Retrofit instructions: ceramic substrate centering for SIPLACE S-27 HM Ceramic substrate centering SIPLACE S-27 HM
12/2004 Edition
52
2.7 Adapting to the size of the substrate
The ceramic substrate centering must be adapted to suit the size of substrate that is to be pro-
cessed in order to ensure 3-point contact of the substrate for centering in the X direction. This is
done by fitting the appropriate stop rail (with 2 ball bearings) and a suitable stop unit (with fixed
roller AND spacer bolt) -> see table below for item numbers.
CAUTION
The stop spacer bolt (set 1 to 3) must not be removed. 2
2
2
2
2
2
2
2
2
2
2
2
Designation for substrate width Item no.
Stop rail 1, complete
with parallel pin
from 50 mm to 62 mm 00358877-01
Stop rail 2, complete from 62 mm to 106 mm 00358884-01
Stop rail 3, complete from > 106 mm to 140 mm 00358885-01
Stop set 1 (complete
with distance bolt)
from 50 mm to 62 mm 00358874-01
Stop set 2 (complete
with distance bolt)
from 62 mm to 106 mm 00358875-01
Stop set 3 (complete
with distance bolt)
from > 106 mm to 140 mm 00358876-01
Ceramic substrate centering SIPLACE S-27 HM 2 Retrofit instructions: ceramic substrate centering for SIPLACE S-27 HM
12/2004 Edition
53
: Detach the complete stop rail fixing on the X-axis carriage unit (2 hexagon socket head screws
M 3, see Fig. 2.7 - 2 -> 4, 5).
: Fit the necessary complete stop rail (see table above and Fig. 2.7 - 1).
Fig. 2.7 - 1 Stop (unit) set 1, 2, 3 and matching stop rail, complete 1, 2, 3
1. Stop (unit) set 1, fixed stop
2. Stop (unit) set 2, fixed stop
3. Stop (unit) set 3, fixed stop
4. Stop rail 1, 2 and 3, complete (see marking 1, 2 and 3), movable stop
5. Travel limiting parallel pin:
MUST be present on stop rail 1
NOTE:
For substrates 50 mm to 62 mm wide that are more than 50 mm long (e.g. twice as long), the stop
set 1 (fixed stop) is fitted together with the complete stop rail "2" (= movable stop) (see table above
and Fig. 2.7 - 1). 2
2
3
1
5
4
4
4