00194598-01.pdf - 第53页
Ceramic substrate centering SIPLACE S- 27 HM 2 Retrofit instructions: ceramic substrate centering for SIPLACE S-27 HM 12/2004 Edition 53 : Detach the comp lete s top r ail fixi ng on the X-ax is carr iage uni t (2 hex ag…

2 Retrofit instructions: ceramic substrate centering for SIPLACE S-27 HM Ceramic substrate centering SIPLACE S-27 HM
12/2004 Edition
52
2.7 Adapting to the size of the substrate
The ceramic substrate centering must be adapted to suit the size of substrate that is to be pro-
cessed in order to ensure 3-point contact of the substrate for centering in the X direction. This is
done by fitting the appropriate stop rail (with 2 ball bearings) and a suitable stop unit (with fixed
roller AND spacer bolt) -> see table below for item numbers.
CAUTION
The stop spacer bolt (set 1 to 3) must not be removed. 2
2
2
2
2
2
2
2
2
2
2
2
Designation for substrate width Item no.
Stop rail 1, complete
with parallel pin
from 50 mm to 62 mm 00358877-01
Stop rail 2, complete from 62 mm to 106 mm 00358884-01
Stop rail 3, complete from > 106 mm to 140 mm 00358885-01
Stop set 1 (complete
with distance bolt)
from 50 mm to 62 mm 00358874-01
Stop set 2 (complete
with distance bolt)
from 62 mm to 106 mm 00358875-01
Stop set 3 (complete
with distance bolt)
from > 106 mm to 140 mm 00358876-01

Ceramic substrate centering SIPLACE S-27 HM 2 Retrofit instructions: ceramic substrate centering for SIPLACE S-27 HM
12/2004 Edition
53
: Detach the complete stop rail fixing on the X-axis carriage unit (2 hexagon socket head screws
M 3, see Fig. 2.7 - 2 -> 4, 5).
: Fit the necessary complete stop rail (see table above and Fig. 2.7 - 1).
Fig. 2.7 - 1 Stop (unit) set 1, 2, 3 and matching stop rail, complete 1, 2, 3
1. Stop (unit) set 1, fixed stop
2. Stop (unit) set 2, fixed stop
3. Stop (unit) set 3, fixed stop
4. Stop rail 1, 2 and 3, complete (see marking 1, 2 and 3), movable stop
5. Travel limiting parallel pin:
MUST be present on stop rail 1
NOTE:
For substrates 50 mm to 62 mm wide that are more than 50 mm long (e.g. twice as long), the stop
set 1 (fixed stop) is fitted together with the complete stop rail "2" (= movable stop) (see table above
and Fig. 2.7 - 1). 2
2
3
1
5
4
4
4

2 Retrofit instructions: ceramic substrate centering for SIPLACE S-27 HM Ceramic substrate centering SIPLACE S-27 HM
12/2004 Edition
54
: Detach the stop (= stop unit) fixing on the X-axis carriage unit (2 hexagon socket head screws
M3, see Fig. 2.7 - 2 -> 6, 7).
: Fit the necessary stop unit 1, 2 or 3 (see table above).
2
Fig. 2.7 - 2 Matching the ceramic substrate centering to the size of substrate
Key: 2
1. Base unit
2. X carriage unit
3. Fixing bracket for stop rail, 2 hexagon socket head screws M3 x 8
4. Stop rail (according to size of substrate: see table above)
5. 2 hexagon socket head screws M3
6. Stop unit with spacer bolt (according to size of substrate: see table above)
7. Fixing for stop unit: 2 hexagon socket head screws M3
8. Fixed stop roller
2
2
2
2