Instructions for changing catch on component feeder table HS-50 11/2001 Issue 16 : Remove the plug c onnector o f the c omponent c art. : Remove the screws on the si de wall o f the plac ement m achine an d remov e the s…

Instructions for changing catch on component feeder table HS-50
11/2001 Issue
15
: Mount the latch bolt on the guard (see the photographs)
: Atttach the actuator using the two PT cheese-head screws.
: Now fix the guard back onto the cover plate.
Note:
Left-mounted
variant

Instructions for changing catch on component feeder table HS-50
11/2001 Issue
16
: Remove the plug connector of the component cart.
: Remove the screws on the side wall of the placement machine and remove the side wall
completely.

Instructions for changing catch on component feeder table HS-50
11/2001 Issue
17
: Remove the plug connector for the component feeder table catch, and then remove the snap-
action switch and cable.
: Attach the new connector and feed the cable round the corner of the placement machine.
: Fix the mounting plate to the side wall using a screw and a washer.
2
Remember to pay special attention to left and right mounting when attaching the plate. 2
. 2