Head PCB - Overview en.pdf - 第13页

a c p a g e

100%1 / 14
Description of the Circuit Boards PP
Head main board C600
12 Head PCB Overview Step by Step Analysis
Further Information
To (2) LEDs (description sequence downwards):
P&P head main board [00352833-xx]
The main board is mounted directly on the P&P head.
This board is connected to the base adapter (SX/DX se-
ries) or the head adapter (X series) via two flat ribbon ca-
bles.
1. 2 connectors for the 16 bit CAN bus processor (not
used for X/D1/D3)
2. LEDs (see below)
3. X54 Jumper currently set to ON, with the new force
measurement board set to OFF (see LED V2/V_SP)
4. Flat ribbon cable connector to the head adapter
5. Flat ribbon cable connector to the head adapter
6. X8: Flex cable (signals: track signals D axis, motor
voltage Z axis/D axis, Z temperature, SPI bus)
7. EEPROM stores the head specific data (head ex-
change, reference run)
8. Power supply 15 V for the D axis track signals (cur-
rently deactivated via the jumper X54)
9. X4 connector, Z axis track signals
10. Connector pneumatic valve (return unit)
11. Hole for pneumatic hose to the vacuum generator
12. X21 connector for vacuum generator
LED Color Description
D8 Green Off – return unit is extending – LED lights up briefly
D7 CLAMP Green On - display showing that the return cylinder has been extended.
D6 BERO Green Off - without function (previously: proximity switch, Z axis top)
D1 PRESSURE Yellow Off - without function (Z pressure)
D2 CLAMP Yellow On – Z axis clamping
Off – return unit is in top position
V2/V_SP Green Shows the 15 V power supply for the D axis track signals.
Off – when jumper setting is ON and with old force measurement board.
On when TwinHead has new force measurement board, the 15 V is reg-
ulated on the main board i.e. the jumper must be set to OFF and the LED
is on.
V3 15V_ Green On – 15 V for the D axis track signals
V1 TEMP Green On - Z axis motor temperature is OK
D14 ALARM Red Off - Alarm output for the vacuum generator
On - Vacuum generator defective
D9 PRESSURE Green Off - without function (Z pressure)
D10 24V+ Green On – 24 V for vacuum generator OK
acpage
Item no.: ASM Assembly Systems Singapore Pte ltd
2 Corporation Road
#01-03 Corporation Place
Singapore 618494
www.e-by-siplace.com