Model DECAN Series Company SAMSUNG TECHWIN Module T roubleshooting T otal Pages 99 [J1004] 相机识别超时错误 ( 发生视觉通信错误 ) ................................................. 84 [J1005] 发生 " 找不到基准点边缘 " 错误 .................…

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
Troubleshooting
Total Pages
99
[G1007] 发生显示器影像变色、颤抖现象 .......................................................... 58
[G1008] 启动 MMI 时,发生 MFC 相关计算错误 ............................................... 59
[H1000] 发生 Pick up Error .............................................................................. 60
[H1001] 零件浮起 .............................................................................................. 61
[H1002] 安装零件错位 ....................................................................................... 62
[H1003] 不能识别零件 ....................................................................................... 63
[H1004] 发生 LED 零件倒插及反转 ................................................................... 64
[H1005] 生产中,发生暂停现象 ......................................................................... 65
[H1006] 喷嘴上吸附零件 ................................................................................... 66
[H1007] 安装程度不合格 ................................................................................... 67
[I1000] 执行 Optimizer 时,出现死机现象 ......................................................... 68
[I1001] 执行 Optimizer 时,停机后不启用 Manager Mode ............................... 69
[I1002] 执行 Optimizer 后,强制关闭 MMI ....................................................... 70
[I1003] Optimizer 错误 ...................................................................................... 71
[I1004] 前面和后面基准点识别位置不同 ............................................................ 72
[I1005] 打开 PCB 文件时,虽然存在文件名,但打不开 .................................... 73
[I1006] 启动 PC 时,弹出日志窗口后,不可启动 .............................................. 74
[I1007] 将 Tape Feeder 设定为 Non,但设定为另外 Tape Feeder 的错误 ...... 75
[I1008] 发生 Assert Error .................................................................................. 76
[I1009] 不能下载 PCB File ................................................................................ 77
[I1010] 发生 MPU 及设备停止 ........................................................................... 78
[I1011] 与前、后设备不能通信 .......................................................................... 79
[J1000] 不能播出 Fly Camera 影像、影像损伤、发生噪点 ............................... 80
[J1001] 视觉命令处理中,发生超时错误 ........................................................... 81
[J1002] 不能播出 Fiducial Camera 影像、影像损伤、发生噪点 ....................... 82
[J1003] 发生基准符号识别错误 ......................................................................... 83

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
Troubleshooting
Total Pages
99
[J1004] 相机识别超时错误(发生视觉通信错误) ................................................. 84
[J1005] 发生"找不到基准点边缘"错误 ................................................................ 85
[J1006] Stage Camera 照明不合格 .................................................................. 86
[J1007] 显示器影像颤抖 .................................................................................... 87
[J1008] 发生错误标记识别错误 ......................................................................... 88
[K1000] 发生 X 轴噪音、震动 ............................................................................ 89
[K1001] 发生"在 Y 轴感应到警报"错误 .............................................................. 90
[K1002] 发生"在 X 轴感应到警报"错误 .............................................................. 91
[K1003] 发生 Y 轴噪音、震动 ............................................................................ 92
[K1004] 发生 Amp 非启用错误(原点复位启动错误) ........................................... 93
[K1005] 发生"驱动轴时,发生过多偏移"错误 .................................................... 94
[K1006] 发生"感应到 H/W Limit"错误 ................................................................ 95
[K1007] 发生"超出台架的 XY 移动范围,不能移动"错误 ................................... 96
[K1008] 发生"台架映射中找不到基准"错误 ........................................................ 97
[K1009] 发生"在 G1F-X,Y 发生追踪误差"错误 ................................................... 98
[K1010] 发生热成像超时错误 ............................................................................ 99

Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
Troubleshooting
Version
01
Title
故障类型分类表
Note
Page
5
[故障类型分类表]
故障症状及部位
Code Case
Air
[A1000]
因漏气发生主气动相关噪音
[A1001]
因漏气发生Head气动部噪音
[A1002]
供给设备的气动异常
Control
[B1000]
Ready开启时,所有轴上不供应电机电源
[B1001]
不能启动PC Rack部风扇
[B1002]
设备之间不可Interface
[B1003]
发生Not Defined Error Code
[B1004]
主断路器(MCCB)发生跳闸
Conveyor
[C1000]
发生STEF,ST1F,ST1R,STXF,WS 警报
[C1001]
不可引入、排出PCB(皮带启动不达标)
[C1002]
BUT 上/下移动错误
[C1003]
不能感应Stopper上升、下降Sensor
[C1004]
发生"AMP未启动。"错误(不能轴复位)
[C1005]
Edge Fixer 开启、关闭失败
[C1006]
发生"电机或原点位置被变更"错误
[C1007]
发生STEF或STXF-S追踪误差错误
[C1008]
发生传输带的宽度调节错误
[C1009]
发生PCB识别错误
[C1010]
发生正常位置上PCB不停止的错误
[C1011]
设备之间不可移送PCB
[C1012]
启动传输带时,发生噪音、震动
Electric
[D1000]
不可操作前/后面操作Panel、Teaching Box
[D1001]
不可启动前/后面键盘或鼠标(不可使用USB)
[D1002]
Tower Lamp不合格(听不到蜂鸣器声)
Feeder & ANC
[E1000]
Head夹住ANC的喷嘴或放下到ANC时,发生警报或错误
[E1001]
发生送料器不可启动及Feeder Base卡槽启动错误
[E1002]
发生"感应到Feeder Unlock"错误
[E1003]
发生"不能打开、关闭ANC 快门"错误
[E1004]
设备开启时,发生送料器先供料的错误
[E1005]
Feeder Base上送料器安装/拆卸不顺畅
[E1006]
发生"Feeder Part Clamp被解除"错误
[E1007]
发生Feeder Tape安装错误