■ Solenoid Valves
NOTE: Do not disassemble the solenoid valves for any purposes. Disassembling them is not covered by the
warranty.
Part No.
Part Name
LG9-M71A1-00X SOLENOID VALVE
■ Air Passage
Clean the air passage (from the air filter assy. to the nozzle) periodically to maintain machine accuracy.
Give an air blow from an air tube.
■ Air Filter
Take out air filter elements from air filter assy., once a week, to check if they are dirty. Replace the elements
if they are clogged with dust.

3 Mechanical Section
3-3
Nozzle
■ Cleaning.
If the dispensing fluid is left in a nozzle for a long time, it will harden. Once the fluid hardens in the nozzle,
the fluid in a syringe cannot be dispensed. So clean nozzles before the fluid gets hard. When you change the
dispensing fluid and when you are not using a nozzle for a long time, clean the nozzle in the same manner.
● Timing of Cleaning
・When the amount of dispensing is coming to smaller.
(When discharging or dot size are coming smaller.)
・When dispensing amount is not stable.
・When using the nozzle after a long interval.
NOTE: Cleaning timing depends on the state of storage. Follow the instruction of the manufacturer for
storing the material.
● Preparations
・ Syringe
・ Saucer
NOTE: Syringe does not need a needle. About 10cc is enough for the syringe capacity.