17 Practical Tips on Using the LC UNIX User Manual Line Computer UNIX 17.5 Line Control Software Version 5 02.xx 10 /2000 Issue 574 I t I I 17.5 Lin e Control The three PCBs ca n now be prod uced usi ng the creat ed set-…

User Manual Line Computer UNIX 17 Practical Tips on Using the LC UNIX
Software Version 502.xx 10/2000 Issue 17.4 Set-Up Generation
573
I
t I I
Fig. 17.4.1 Definition of a Waffle-Pack Tray
47. Click on the Quit option on the FILE menu.
The Packaging Editor is closed. The pick-up area of the waffle-pack tray is displayed together with the
indicated spacing.
To allocate a component to a waffle-pack tray, proceed as follows:
48. On the component list click on the component, here: Comp5.
49. Click on the blue pick-up area of the waffle-pack tray.
The component is allocated to the compartments of the waffle-pack tray.
To save the set-up, proceed as follows:
50. Click on the Save option on the FILE menu.
The created set-up is saved.
51. Click on the Quit option on the FILE menu.
The Set-Up Editor/WPC Editor is closed.
To adjust the conveyor width (if not already done), proceed as follows:
52. On the desktop click on the Line control option on the SERVICES menu.
The Line control window is opened.
53. Click on the Conveyor width button.
A dialog box is opened.
54. Activate the Width adj. upon cluster change button.
With this function, the conveyor width is adjusted automatically upon the next cluster change.
55. Click on the OK button.
The dialog box is closed.
56. Click on the Quit option on the FILE menu.
The Line control window is closed.

17 Practical Tips on Using the LC UNIX User Manual Line Computer UNIX
17.5 Line Control Software Version 502.xx 10/2000 Issue
574
I
t I I
17.5 Line Control
The three PCBs can now be produced using the created set-up.
Opening Job Control
Scheduling a job
Displaying and printing
set-up changeover in-
structions
Changing the set-up of
stations and confirming
set-up changeover
Inserting jobs in the job
list
The placement of the
scheduled jobs is
started.

User Manual Line Computer UNIX 17 Practical Tips on Using the LC UNIX
Software Version 502.xx 10/2000 Issue 17.5 Line Control
575
I
t I I
To open Job Control, proceed as follows:
1. On the desktop, click on the Job icon.
Job Control is opened.
To insert jobs in the job list, proceed as follows:
2. Activate the Create icon .
3. Activate the Edit support icon .
The Edit support Job Data is opened.
4. Successively select the following data by double-clicking: the PCB, here: Example_1.la, the line, here:
SMT.ak, the subline, here: Linie.va and the set-up, here: Examples01.ar.
The Edit support Job Data is closed, return to Job Control.
The selected data now appear in the editing area below the job list.
5. In the editing area click on the Lot name field and enter the lot name, here: ex1.
6. In the editing area click on the Lot size field and enter the lot size of the job, here: 10.
7. In the editing area click on the Lot type field and enter the lot type, here: F.
8. Click on the OK button.
The job is transferred to the job list. In the case of faulty entries, the field concerned is surrounded by a
red frame and an error message is displayed above the job list. Correct the entry.
9. Insert the remaining PCBs analogously, here: Example_2.la and Example_3.la, see chart.
To schedule a job, proceed as follows:
10. Click on the Schedule icon .
On the job list successively click on the individual jobs.
The jobs are checked for producibility and then passed to the station controller after the successful com-
pletion of the producibility check.
The Set-up Modification Generator is opened.
If errors are encountered during the producibility check, the status of the lot file is indicated by means of
an
E (Error). In the case of an error, proceed as follows:
— Click on the faulty job.
The job is highlighted.
— Click on the Error messages... option on the SERVICES menu.
The File display containing the error messages is displayed.
— Correct the errors displayed.
— Schedule the job once again.
To display and print out set-up changeover instructions:
11. In the Set-Up Modification Generator activate the Set-up modification instructions button.
The set-up changeover instructions are displayed.
12. On the FILE menu click on the Print command, then Print Line.
The set-up is printed out for all stations.
To change the set-up of stations and to confirm the changeover, proceed as follows:
13. Change the set-up of the stations in accordance with the set-up changeover instructions.
14. Once the set-up of the stations has been changed over, select the individual stations in the selection field
and click on the Set-up modified button for each station.
The job is only scheduled and placement is started, when the set-up changeover of all stations has been
completed.
The Set-Up Modification Generator is closed.
The assembly of the PCBs is started.
PCB Lot name Lot size
Lot
type
Example_1.la ex1 10 F
Example_2.la ex2 13 F
Example_2.la ex3 16 F