4 Service work – HCSII Head Unit 4.17 Replacing the GigE Board 50 Service Manual SIPLACE Head Care Station II 11/2019 Fig.71: Removal 4 ► Remove the assembly frame (2) from the GigE Board (1) . Installation ► Follow …

100%1 / 68
4 Service work – HCSII Head Unit
4.17 Replacing the GigE Board
Service Manual SIPLACE Head Care Station II 11/2019 49
Fig.69: Removal 2
GigE Board – rear view(1)
► Open any cable ties where necessary.
► You may want to mark the positions of
the relevant connections to make clear
assignment easier later on.
► Unplug the red GigE cable J2(2).
► Unplug the cable J5(3).
Fig.70: Removal 3
► Pull the GigE Board forward out of the
frame.
► Unplug the cables J6 und J7(1). Be
sure not to mix up these two cables.
► Carefully remove the GigE Board.
4 Service work – HCSII Head Unit
4.17 Replacing the GigE Board
50 Service Manual SIPLACE Head Care Station II 11/2019
Fig.71: Removal 4
► Remove the assembly frame(2) from
the GigE Board(1).
Installation
► Follow the removal instructions in reverse order for installation.
► Replace any cable ties which you have removed.
5 Service work – HCSII Control Box
5.1 Equipment and tools
Service Manual SIPLACE Head Care Station II 11/2019 51
5 Service work – HCSII Control Box
DANGER
Observe safety instructions!
► Please observe the safety instructions in this Service Manual and in the HCSII User
Manual for all work!
NOTICE
Observe the detailed circuit diagrams!
► For more detailed information refer to the circuit diagrams folder of the HCSII.
●
Detailed circuit diagrams folder for HCSII [DEEN:00198762‑xx]
5.1 Equipment and tools
Equipment and tools needed for service work on the HCSII Control Box:
00319064-xx Screwdriver philips Size 1
00353832‑xx Allen key set 2 mm, 2.5 mm, 3 mm
00096290-xx Spanner wrench set 5.5 mm, 10 mm
Slot screwdriver set Size 1, size 2
00096487-xx Angled tweezers 140mm oval
00318673-xx Side cutter electronic Size 110
00308458-xx Cable ties B=2.5mm, L=102mm Panduit
00198498‑xx Installation manual "WES7 and SW709.1 for
HCS"
5.2 Replacing the PCB Power Adjust HCSII compl. (PCB1/PCB2)
DANGER
Hazardous voltage
Death, serious injury or considerable damage may result if the power supply is handled
incorrectly.
Only SIPLACE service technicians or adequately trained personnel, e.g. certified electrical
specialist, are allowed to perform this task on the power supply.
Parts
Fig.72: PCB Power Adjust HCSII compl.
●
PCB Power Adjust HCSII compl.
[03090149‑xx]
 NOTICE!
PCB1 is connected to PS4.
PCB2 is connected to PS3.
.