F5HM Circuit Diagrams.pdf - 第90页
2 Circuit Diagr ams 90 0020003 4-030101 LD3 Signa l decoupli ng unit 3 4 1 2 +- +- +- +- 34 2 1 34 2 1 Name Norm Beab. Urspr./E rs.f./Ers.d . Bl. Bl. Stromla ufplan/C ircuit diagram Datum Aenderun g Zustand Datum Gepr. 1…

2 Circuit Diagrams 89
00337342-030101TD3 Terminal panel, righthand side
L2
L3
X206
6
4
A2
10
220mm
X
X
1
6
X
END
X1rcX1rb
X2re
7
X
XX
N
N
N
N
N
3
D
C
15
Cable duct 65x30 l=335mm
L2
X
5 8
E
FF
2
X
10
X206
L1
L1
L1
L2
L2
Cable duct 65x46 l=155mm
7
345
130mm
X
XX
11
12
A
Note: X means that one lug must be knocked out
420mm
8
9
N
5
116mm
4
PE
PE
PE
PE
X
10
Cable duct 65x66 l=460mm
Note: X means that one lug must be knocket out
8
8
16
Cable duct 65x30
E
B
2
C
D
17
18
18
19
6
35mm
190mm
252mm
L3
L3
L3
13
14
B
X2rb
6
5
500mm
12
l=120mm
A
7
L1
4
X
XX
Leh
Leh
03
01
01
21.10.98
12.03.98
08.06.98
21.10.98
Tuth
#
Terminal panel, righthand side
00337342-030101TD3
Cable duct 65x46 l=430mm
1
X207
A
PE
PE
PE
PE
PE
PL EA1 E5
Leh
Contact washer SN 70093
Nut DIN 439
Annular cable lug
Washer DIN 125
Split washer DIN 7980
Nut DIN 439
=
Datum
Gepr.
Norm
Bearb.
Blatt
Urspr. Ers. f. Ers. d.NameDatumAenderungZustand
SIEMENS AG
Bl.
+
D:
XX
D
B
55mm
A5
A4A3
C
acc. to BV 00343603, Sh.2
Ground connection
PE
X
X
270mm
X1rd
XX
315mm
0mm
X
Please note:
- Jumper X207 13-14-15-16-17 should be moved to
X207 11-12-13-14-15 when the X and Y axes
are started up for the first time.
This will switch from 1L+ (100V) to 4L+ (8V),
thus reducing the risk of a head crash.
SIEMENS PLEA 1
00337342-03
AA-BBBB-CCCC
40
20
X2rdX2rc
3
X
SMD-Placement System Siplace S23
Product status
Doc. status
Function status
The following labels have to be applied:
A: Identification label
Space for voltage label from NAFTA lable set (for USA only)
C: Ground label
B: Inspection label
Identification: Testing engineer, month, year
BBBB = Date (year/month/day) acc. to SN 01007
AA = Manufacturer/location acc. to SN 37040
CCCC = Series number
Font size 2.5mm Material Scotchcal 3698-E (Color A1 RAL 9006)
Assembly inscription acc. to guideline VA - F - 510 - 001
Screw

2 Circuit Diagrams 90
00200034-030101LD3 Signal decoupling unit
34
12
+-
+-
+-
+-
34
21
34
21
Name Norm
Beab.
Urspr./Ers.f./Ers.d.
Bl.
Bl.Stromlaufplan/Circuit diagramDatumAenderungZustand
Datum
Gepr.
1816151413121110987654321 17
CAD-Datei :
Mat.-Nr. :
SIEMENS
AUT 5
Product status
Doc. status
SMD Placement System Siplace 80S
1
1
29.10.1990
Tekin
Optical decoupling
unit
1. Tu.
14.06.96
GND 24V
X1 9
K1
13
6
9
1 2 3
JP2
X5 8
1413
GND 24V
GND 24V
10 11 12
5
6
7
X5
X5
X5
GND 24V
Received
Permission
151413X3
65
Permission
Received
MP2
MP1
1K5 1,1W
R1
0,1uF
C1
Request
GND n-1
19 20
Request
U1
MP4
GND 24V
11
loop
K1
1
7
Fault signal
12
1K5 1,1W
R2
0,1uF
C2
Transferred
18
previous station
To
U2
6
Transferred
2K7
R8
2K7
R7
MP3
2K7
R5
2K7
R6
Permission
Received
Transferred
Request
+24VDC
Spare
Spare
Spare
1098
+30VDC unswitched
+24VDC
123
GND 24V
X7
X7
X7
X7
X7
1
2
3
4
5
6X7
Spare
Spare
Spare
Spare
Spare
Spare
1
2
3
JP1
MP9
V2
+-
V1
+-
V3
+-
V4
+-
ye
ye
gn
gn
gn
gn
ye
ye
V8
V7
V5
V6
Spare
Spare
Spare
9810X4
+24VDC
GND 24V
+30VDC unswitched
564
2K7
R11
2K7
R12
2K7
R10
2K7
R9
Permission
Transferred
Request
Received
11
Fault signal
12
loop
following station
To
1K5 1,1W
R3
0,1uF
C3
Permission
15
7
Permission
U3
MP5
GND 24V
1K5 1,1W
R4
0,1uF
C4
Received
GND n+1
1413
8
Received
U4
MP6
Request
GND 24V
Transferred
18 19 20
7
Transferred
Request
MP7
MP8
X1 8X2 5
Tu.
14.06.96
3.
Output 1
Output 2
Output 3
Output 4Output 4
Output 3
Output 2
Output 1
6
7
8
X6
X6
X6
5 X6
12111091234
+ X6
+24VDC
+24VDC
+24VDC
+24VDC
Input 1
Input 2
Input 3
Input 4 Input 4
Input 3
Input 2
Input 1
+24VDC
U
U
X5
X5
P
P
M
X5
X5
X5
M X5
+30VDC unswitched
+30VDC unswitched
GND 24V
GND 24V
+24VDC
+24VDC
G X5
1234
GND 24V
GND 24V
GND 24VX6
X6
X6 -
-
-
GND 24V
GND 24V
X2 13 14
+30VDC switched
+30VDC switched
+30VDC switched
+30VDC switched
+30VDC switched
00200034-030101LD3
1.
Tu.
14.06.96
Function status
00200034
00200034-03
34
12

2 Circuit Diagrams 91
00344266-010301LD3 Circuit diagram, terminal panel, lefthand side (Sh. 1 of 2)
=
Datum
Gepr.
Norm
Bearb.
Blatt
Urspr. Ers. f. Ers. d.NameDatumAenderungZustand
SIEMENS AG
Bl.
+
lifting table X12
PCB 1/2 transport control
conversion board
Terminal board, lefthand side
Circuit diagram
SIPLACE 80F4/F6/F5-HM
SMD Placement System
PL EA1 E5
14.04.99
06.10.98
00344266-010301LD3
#
Tuth
14.04.99
06.10.98
To signalling circuit EMERGENCY STOP button
GND EMERG. Stop external
From signalling circuit , safety switch2
sheet 2
10
***
Note:
On SIPLACE F5-HM machines *** cable
is not installed. Fit jumper between 4-5
Option
From signalling circuit EMERGENCY STOP button
ye
on X211.
control board
To control circuit , safety switch3
5kg
table
righthand side
00321417-xx
00305815-xx
To
00322105-xx
WPC interface
bk
vio
00321509-xx
ye
indicator
main fault
8
2
6kg 8
vio
gr/pk
2kb
6
X
Valve Ceramic substr. cent.1
From signalling circuit EMERGENCY STOP button
To control circ. EMERGENCY STOP button
To Key switch
EMERG. Stop external
gr
X
pk
00321416-xx
2
16 17
6
8
To control circuit , safety switch2
ON button
-
gn
3
X
To
conversion board
5
1
X210
gr
rd
bl
To signalling circuit EMERGENCY STOP button
To signalling circuit ON button
From signalling circuit ON button
Hood switch
1
To
18
00321529-xx
00318689
(output side)
X
-xx
2ka
4
hbl
CO
table
lh. side
vio
00326069-xx
+
ye
2ka
X
5
gr/pk
7
Guard open
2kd
X+
From signalling circuit , safety switch1
wh
+24V
From control circuit , safety switch2
rd/bl
To control circuit , safety switch1
ye
From signalling circuit , safety switch3
From signalling circuit , safety switch4
CO
GND
8
Hood switch
From control circuit2 ON button
To control circuit1 ON button
From control circuit1 ON button
To CO table (EMERG-S-Circuit)
To
gn
From ctrl. circuit EMERGENCY STOP button
gn
input side
ye
X+2kd
ye
ye
wh
3
00321574-xx
5
5
hbl
br
br
8
From control circuit , safety switch4
nozzle
19
Lifting table1 up
To
operating panel
To control circuit EMERGENCY STOP button
pneum. sys.
To control circ. EMERGENCY STOP button
From CO table (EMERG-S-Circuit)
bl/bk
bl/bk
bl/bk
00321432-xx
X7
X
From control circuit ON button
2ka
changer
2kd
GND
+
8
X-
X
-xx
6
X211
7
From control circuit , safety switch1
2
Lifting table1 down
Valve Stopper1 ,extend
Valve Stopper2 ,extend
wh
gr
pk
00322111-xx
00322104-xx
00322112-xx
righthand side
wh
gn
br
From WPC (EMERG-S-Circuit)
To WPC (EMERG-S-Circuit)
EMERG. Stop external
3
X
-
GND EMERG. Stop external
From WPC (EMERG-S-Circuit)
To WPC (EMERG-S-Circuit)
00321528-xx
From signal. circuit EMERGENCY STOP button
To signalling circuit EMERGENCY STOP button
2kc
X
br
pk
bl
00322070-xx
br
3
ye
Signal, Lifting table1 bottom
1
211
rd/bl
5
7
2
X
From CO table (EMERG-S-Circuit)
2kb
2kb
br
20 4 5
From Key switch
To control circuit2 ON button
11
gr
pk
12
20
16
To
00322333
X210
wh
wh
Prox. switch Position width adj.1
Prox. switch Stopper2 on
wh
gn
br
ye
00321573-xx
Hood switch
lefthand side
lefthand side
To
WPC interface
-
2kf
2kf
gr
pk
br
2kd +
11-12 X211 (connecting rail)
6
Warning!
br
X210
2kb
E
X+
2kd
5
2kd
Signal, Lifting table1 top
Prox. switch Stopper1 on
2kd
00303614-xx
2
X210
video
-xx
7
211
5
6kg
wh/gn
X6kg
From CO table (EMERG-S-Circuit)
wh/ye
br/gn
5kg
pk
ye
gn
00300912
2kd
bl/bk
br
gn
2kd
Prox. switch Ceramic substr. cent.1
Signal, End of width adj.1
-
(output side)
00321529-xx
5
2kd
wh
1,5mm²
+24V
bk
rd
3
X211
1
-
3
bk
must be removed.
319
If 00305816-xx cable is connected,
X
X
Fault indicator lamp
Fault indicator lamp
Motor width adj.
X
Motor width adj.
Ultrason. s. Output conv.1
Ultrason. s. Output conv.2
Ultrason. s. Input conv.1
X
18
operating panel
(input side)
2kd
X+
X
2kb
2kb
machine
wh
gn
00321434-xx
To
rd
314
X211
21
3
00321436-xx
X
2
M44
X
GND
+24V
Air pressure sensor
GND
X4
X
2kf
gn
ye
X
pk
gn
rd
bl
gn
br
8
2kf
2kf
gn
6kgX
8
ye
4
7
To
Motor width adj.
Nozzle changer 1 closed
+24V
GND
GND
5ki
C
B
A
00326068-xx
ye
gr/pk
2
2ka
3
1 8
X
ye
X2kf
4
X
X
2
5
X
7
4
+24V
GND 24V
wh
IcosMC1
Fault indicator lamp
XValve nozzle changer 1
Nozzle changer 1 open
6
+
X6
5
X
wh
6
GND
2
2kc
2kc
00317579-xx W1
X2kc
5
interfaces
X
X211
operating panel
To control circuit , safety switch4
X
8
F
17
2ka
15
00305816-xx
X210
hood switch
9
(input side)
00321528-xx
To
4
23
00322069-xx
0,5mm²
00322356-xx
00301486-xx
br
X212
To control circuit2 ON button
wh
EMERGENCY STOP button
2kd
4
jumper
2kc 1
X
Continued on
-xx-xx
X
Key switch
2kc
To control circuit1 ON button
F
X
X
X
1
6
A
B
C
D
E
Ultrason. s. Center conFrom2
Ultrason. s. Center conFrom1
rh. side
11
X211
4
00322063 00322064
(00321421-xx)
00321433-xx
multiplexer
To
11
5ki
br
br
lifting table X13
3
2kb
X
7
X
From control circuit2 ON button
gn
From control circuit1 ON button
rd
+24V
+24V
+24V
2kc
X
5
Motor width adj.
Motor width adj.
Motor width adj.
X
X
2kd
6
bk
D
rd/bl
From signalling circuit ON button
From control circuit OFF button
From signalling circuit EMERGENCY STOP button
+24V (cart 1-4)
5ki
X210
6
X
vio
7
To
7
preceding
2ka
5kg
X
OFF button
6
X
PCB 1/2 transport control
wh
br
gn
wh
Ultrason. s. Input conv.2
Vakve Ceramic substr. cent.2
br
gr/pk
gn
gr
operating panel
From control circuit , safety sw.3
6
wh
Document status
Product status
Function status
01
03
01
Leh
Deu
Leh
5ki
2ka
910
3
2kd
X2kd