Power supply 400V, 32A, 50Hz (3+N+PE) UL 400V, 32A, 60Hz* (3+N+PE)
Pmax 15 kW 15 kW
Compressed air connection Pipe Ø 6 mm Pipe ID 0.24 in
Recommended working pressure 4,5 – 6 Bar 65,25 – 87 PSI
Compressed air quality 3. Class ** 3. Class **
Exhaust pipe diameter Ø 100 mm ID 3.94 in
Exhaust pipe capacity 580 m
3
/h 20450 ft
3
/h
Minimum liquid for  rst run 3 x 100 l 3 x 26.4 gal
Service space required around the device 600 mm 23.6 in
* When using frequency convertor
** According to the norm ISO 8573-1
INSTALLATION REQUIREMENTS
RIGHT
VIEW
RIGHT
VIEW
TOP
VIEW
BACK
VIEW
110 mm
4.33 in
400 mm
15.7 in
Ø 100 mm
ID 3.94 in
Ø 100 mm
ID 3.94 in
115 mm
4.53 in
discharge of the fluids G 1“
input el. power
input air pressure 2 x Ø 6 mm
input air pressure2 x ID 0.24 in
1210 mm
47.6 in
195 mm
7.68 in
Ø 100 mm
ID 3.94 in
1020 mm
40.2 in
metric units imperial units
Sonix
®
355 CRRD 
TECHNICAL DATA SHEET
6
www.dct.cleaning
4 process chambers – manual solution
100% closed loop uid system
Cleaning and rinsing uid heating
Mechanical ltration
Hot air drying
Emergency stop button
Manipulation wheels – lockable
PLC controller + 5,7“ touchscreen display
Spare parts (base kit)
STANDARD HARDWARE EQUIPMENT
Standard software language mutation – CZ, ENG
Fluid and lter replacement notication – cycle counting
Possibility of 5 programs – setting option
STANDARD SOFTWARE EQUIPMENT
Sonix
®
355 CRRD 
TECHNICAL DATA SHEET
7
www.dct.cleaning
Adjustable timer of cleaning uid heating
Language mutation (CZE, ENG, GER, POL, CHI, RUS, ITA, SPA, MAY, HUN)
ONLINE access to cleaning device
Upgrade machine for PROTON
OPTIONAL SOFTWARE EQUIPMENT
Conductivity measurement – rinse 0–2000 µS – blocking optional
Conductivity measurement – pre-rinse 0–2000 µS – blocking optional
Control of external exhaust ventilator
External ltration
Stainless steel dip tray
Other optional equipment - the complete list of optional accessories will provide you DCT or the local distributor.
OPTIONAL HARDWARE EQUIPMENT
Mechanical holder for basket
Mechanical basket
OPTIONAL ACCESSORY – FRAMES AND OTHERS