E-by SIPLACE Base Machine Undock COT from Ma chine Operation 2/2 CAUTION! Refer to safety inst ructions in user manual before working on the machine. ESD guidelines are to be followed Tool: Wear Part: Consum ables: 7. Cu…

100%1 / 10
E-by SIPLACE Base Machine Undock COT from Machine
Operation
1/2
CAUTION! Refer to safety instructions in user manual before working on the machine.
ESD guidelines are to be followed
Tool: Wear Part: Consumables:
1. Click on "display feeders, components and
nozzles" icon.
2. Click on "location 2 arrow" icon to undock
the COT, the table will now undock automati-
cally.
3. Press stop button.
4. Open the safety cover. 5. Unplug the cable connections. 6. Carefully pull out the feeder tables.
E-by SIPLACE Base Machine Undock COT from Machine
Operation
2/2
CAUTION! Refer to safety instructions in user manual before working on the machine.
ESD guidelines are to be followed
Tool: Wear Part: Consumables:
7. Cut all the waste component tapes back to
the feeders.
.
E-by SIPLACE Base Machine Docking COT to Machine
Operation
1/2
CAUTION! Refer to safety instructions in user manual before working on the machine.
ESD guidelines are to be followed
Tool: Wear Part: Consumables:
1. Make sure that waste component tapes are
cut back to feeders.
2. Move new feeder table into machine and
check if table is at correct height.
3. Connect the cable connector.
4. Close the safety cover. 5. Click on "location arrow" icon to dock the
COT, the table will now dock automatically.
6. Click on "check sensors and functions"
icon.