TDS-injet-388-TRIPLE-CRRD_31.10..pdf - 第6页

InJet ® 388 TRIPLE CRRD TECHNICAL DATA SHEET www.dct.cleaning 6 3 process chamber - fully automatted solution 100% closed loop uid systém 3 arm rotation - electric powered - cleaning 2 arm rotation - electric powered - …

100%1 / 8
InJet
®
388 TRIPLE CRRD
TECHNICAL DATA SHEET
www.dct.cleaning
5
metric units imperial units
Power supply 400 V, 32A, 50Hz (3+N+PE) UL 400 V, 32A, 60Hz (3+N+PE)
Pmax 16 kW 16 kW
Connection to central air pressure Pipe Ø 6 mm and Ø 10 mm Pipe ID 0.24 in and ID 0.39 in
Recommended working pressure 5 Bar 72.5 PSI
Exhaust pipe diameter - 3x Ø 100 mm ID 3.94 in
Exhaust pipe capacity 580 m
3
/h 20450 ft
3
/h
Minimum liquid for rst ll 2 x 75 L 2 x 19,8 gal
Service space required around the device 600 mm 23.6 in
INSTALLATION REQUIREMENTS
FRONT
VIEW
TOP
VIEW
1860 mm
73.2 in
LEFT
VIEW
1205 mm
47.4 in
discharge
of the fluids
845 mm
33.3 in
845 mm
33.3 in
3200 mm
126 in
3200 mm
126 in
570 mm
22.4 in
Ø 100 mm
ID 3.94 in
Ø 100 mm
ID 3.94 in
190 mm
7.48 in
InJet
®
388 TRIPLE CRRD
TECHNICAL DATA SHEET
www.dct.cleaning
6
3 process chamber - fully automatted solution
100% closed loop uid systém
3 arm rotation - electric powered - cleaning
2 arm rotation - electric powered - rinsing
Cleaning and rinsing uid heating
2 hot air blowers - drying
Chimney ap - electronically controlled
Pneumatic door lock
Emergency stop button
Manipulation wheels - lockable
Electronic monitoring of the uid pressure
PLC controller + 8,4“ touchscreen display
Spare parts (base kit)
STANDARD HARDWARE EQUIPMENT
Electronic monitoring of uid level
Electronic monitoring of uid pressure
Electronic cycle counter
3 level of logging - operator, maintenance, technician
Spraying uid pressure - continuous measurement
Standard software language mutation - CZ, ENG
Liquid and lter replacement notication – cycle counting
Possibility of 5 programs - setting option
Smart warning - low or high pressure level
Smart warning - low uid level
STANDARD SOFTWARE EQUIPMENT
InJet
®
388 TRIPLE CRRD
TECHNICAL DATA SHEET
www.dct.cleaning
7
SW for CVA calculation ( android, machine )
Adjustable timer of cleaning uid heating
Upgrade machine for PROTON 69
Language mutation (CZE, ENG, GER, POL, CHI, RUS, ITA, SPA, MAY, HUN)
Online access to cleaning device
and other equipment ...
OPTIONAL SOFTWARE EQUIPMENT
Common uids draining- manual control
Automatic cleaning uid relling (without pump)
Automatic cleaning uid discharging (without pump)
Tanker 200 and 400 L - rinse uid
2 PR sandwich ltration - integrated
Sandwich ltration - external
and other equipment ...
OPTIONAL HARDWARE EQUIPMENT
Mechanical carrier frame - PCB
Mechanical carrier frame - frameless stencils
Mechanical carrier frame - frame stencils
Mechanical carrier frame - VectorGuard stencils
Mechanical carrier frame - squeegees
Mechanical carrier frame - frame and VG stencils (reduction)
and other equipment ...
Traceability OFF line, CSV to SD card
Traceability OFF line, Reader, CSV to SD card
Traceability ON line, PC WIN, le
Traceability ON line, READER, PC WIN, le
Traceability ON line, PC WIN, OPC Server CD, no le
Traceability ON line, PC WIN, READER, OPC Server CD, no le
and other options ...
OPTIONAL ACCESSORY – FRAMES AND OTHERS
OPTIONAL TRACEABILITY