FAE2-110-MANUAL.pdf - 第3页

Features M5 Pr e f ilt er R e f . F A E 2 - 11 0 H 13 F i l t e r + Pre f il te r R e f . F A E 2 -1 0 0 Fume Extr actor R e f. FA E 2 - 5 A ww w .jbct ools.com 3

100%1 / 8
Packing List
The following items should be included:
FAE2 M5 Pre-Filter
Ref. FAE2-110
Manual ........................................................... 1 unit
Ref. 0020108
FAE2 M5 Pre-Filter ..................................5 units
Ref. FA E 2-110
INSTRUCTION MANUAL
2
www.jbctools.com
Features
M5 Pre filter
Ref. FA E 2-110
H13 Filter
+ Pre filter
Ref. FAE2-100
Fume Extractor
Ref. FAE2-5A
www.jbctools.com
3
Replacement
Read safety guidelines to do the
equipment maintenance securely.
- The unit notifies through both the display and
the LED when filters need maintenance.
- To replace the pre-filter, first turn the fume
extractor off. Then remove the cover by
opening the side closures of the casing.
- Insert the pre-filter according to the arrows
in the upper part.
- If once the pre-filter has been changed the
saturation indicator is on, it means that the
main filter is already saturated and must
be replaced too.
- If the display shows an error message when
the equipment is switched on, it is probable
that the cover and casing connectors are
dirty and making false contact between them.
Remove the cover and clean both connectors.
4