3.24 1.000 TM2657
TM2657TM2657
TM2657 23
2323
23 Add YSP History
Thefollowingitemshavebeenaddedtotheinspectionresultfile.
1.Areamm2:Valueof[Inspection]-[Object]-[Area(mm^2)]
2.AreaUpperTol:Valueof[Inspection]-[Object]-[AreaUpperTol.(%)]
3.AreaLowerTol:Valueof[Inspection]-[Object]-[AreaLowerTol.(%)]
4.PatternName:Valueof[Inspection]-[Object]-[PatternName]
5.PartsName:Valueof[Inspection]-[Object]-[PartsName]
Itismodified.
3.24 1.000 TP2016
TP2016TP2016
TP2016 24
2424
24 Add Editor Boarddata
Afunctionhasbeenaddedtoexecutethefollowingmenueswithcombinedboarddata.
1.[Menu]-[Tool]-[BlockOffset]
1)[PitchDistribute]
2)[BlockDitribute]
3)[BlockDistributeReturn]
Itismodified.
3.24 1.000 TP1987
TP1987TP1987
TP1987 25
2525
25 Add
AllMounter,
Editor
GUI
Afunctionhasbeenaddedtodisplaytheline-numberonthefollowinggrids.
1.VGOS
1)[Board]-[Mount]
2)[Board]-[Mount]-[Teach]
3)[Board]-[Sequence]
4)[Board]-[Sequence]-[Teach]
5)[Setup]-[HalfwayContinue]-[Mount]
6)[Setup]-[HalfwayContinue]-[Sequence]
2.Editor
1)[Machine]-[Board]-[Mount]
2)[Machine]-[Parts]
Itismodified.
3.24 1.000 TM2336
TM2336TM2336
TM2336 26
2626
26 Change
YSSeries
Mounter
PickPosition
Correction
AfunctionhasbeenchangednottoclearinformationofPickPosCorrectionoftheSS
feederpartswhileloadingboarddata.
Correctedinformationofallpartsusedtobecleared.
Itismodified.
3.24 1.000 TM2499
TM2499TM2499
TM2499 27
2727
27 Change YSP PSC
Thesoldersupplyactionhasbeenchangedasfollowswhen"Feedback"isselectedfor
[Machine]-[MachineData]-[PSCSetting]-[SupplyMode]andtherollingactionis
executedwiththe[Setting]-[Setting]-[Rolling]button.
Beforethechange:Autosupplyfromthesolderwidthmeasuringresult.
Afterthechange:Manualsupplywiththe"NextSolderSupply"button.
Itismodified.
3.24 1.000 TT5731
TT5731TT5731
TT5731 28
2828
28 Change Optimizer Optimization
The"Palletnumberautomaticdecision"functionhasbeenchangedtopermit
overlappingofthepalletnumbersbetweenthefollowingparts(thosepartsarenotthe
targetof"palletnumberautomaticdecision").
1.Alltraypartswith[Setoptimizationparameters]-[BasicCondition]-[Exec
Condition]-[FeederSetCondition]setto"AllPartsFixed".
2.Traypartswhose[Parts]-[Option]-[UseFeederOptimize]aresetto"No".
3.Partswhosenamesarethesameasthoseoftraypartsregisteredinthefixedboard.
Itismodified.
*
3.24 1.000 TT5642
TT5642TT5642
TT5642 29
2929
29 Bug Mounter GUI
Therewasabugthatappropriatetextswerenotdisplayedonthefollowingscreens.
1.The[Undetected]textswerenotdisplayedonthe[BadmarkFindBest]screen,when
[Mark]-[Basic]-[MarkType]wasselected"Badmark".
2.[AlignmentGroup]textswerenotdisplayedonthe[VisionAlgorithmSelect]screen.
Itisfixed.
3.24 1.000 TT5445
TT5445TT5445
TT5445 30
3030
30 Bug Mounter ErrorMessage
"Ea100:EMERGENCYSTOPFUNCTIONISACTIVE"wasdisplayedwhileloadingevenin
acasethatthe"Ea239:BLOCKCOUNTWARNING"messageshouldhavebeen
displayed.
Itisfixed.
3.24 1.000 TT5782
TT5782TT5782
TT5782 31
3131
31 Bug Mounter
Schedule
Specification
Underallofthefollowingconditions,therewasabugthat"Ea2874BOARDAUTO
SWITCHINGFAILURE"occurredinapositionwheretheboarddatawassupposedtobe
loadedautomatically.
1.[SoftwareSetting]-[History]-[History]-[RemembertheLotlog]:"Exist"
2.Afterturningonthepowersupply,theshaftblowbytheschedulespecswas
executed.
Itisfixed.
3.24 1.000 TT5603
TT5603TT5603
TT5603 32
3232
32 Bug Mounter Teach
Therewasabugthatpartsdatawererecordedwithwrongvaluesthroughthefollowing
procesures.
1.Selected"Parts1"andclickedtheTeachbutton.
2.Selected"Parts2"afteritmovingtotheteachscreenclickedthe[PitchTch]button.
3.Saved[PitchTch]over"parts1data"eventhough"parts2"wasselected.
Itisfixed.
3.24 1.000 TT3545
TT3545TT3545
TT3545 33
3333
33 Bug Mounter Markadj
Therewasabugthatthevaluesof[IROuterLight]and[IRInnerLight]weredisplayed
oppositelyonthefollowingscreens,
1.The[Mark]-[MarkAdjust]screen.
2.The[Mark]-[MarkAdjust]-[MarkLight]screen.
Itisfixed.
3.24 1.000 TT5627
TT5627TT5627
TT5627 34
3434
34 Bug Mounter
Remote
Control
Therewasabugthatthemounterapplicationwasabnormallyended,
whenanothercommandwasoutputwhilethepreviouscommandbeingexecutedby[M-
Tool]-[RemoteControl]
Itisfixed.
MDOC-VG30-00001 12/17

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNote(English) 2011/2/1
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.24 1.000 TT5728
TT5728TT5728
TT5728 35
3535
35 Bug Mounter Boarddata
Underanyofthefollowingconditions,therewasabugthatthe[Network]buttondidn't
becomegrayedout,anditwaspossibletosetthelocation.
Asaresult,unintendedboarddatawasselectedorboarddatawassavedinthe
unintendedlocation.
1.Tappedthefollowingbottunswithoutsetting[Setup]-[SoftwareSetting]-
[Network]-[Network]-[ServerPath:]
1)Tappedthe[Setup]-[Board]buttons.
2)Tappedthe[Save]button.
2.Tappedthe[Save]-[Boarddatasavedialog]-[rename]buttons.
Itisfixed.
3.24 1.000 TT5329
TT5329TT5329
TT5329 36
3636
36 Bug Mounter Recognition
Therewasabugthattherecognitionimagewasnotdisplayedontheeachrecognition
screenofthe[Monitor]etc,whenthepartswhose[Parts]-[Shape]-[BodySizeY
(mm)]wasmorethan"93.000"wererecognized,
Itisfixed.
3.24 1.000 TT5769
TT5769TT5769
TT5769 37
3737
37 Bug Mounter Assistant
Therewasabugcausingthatcharacterstringswiderthanthe[Value]comboboxon
thefollowingscreenscouldnotbeinput.
1.[Board]-[Mount]-[Assistant]-[Replace]
2.[Board]-[Sequence]-[Assistant]-[Replace]
3.[Board]-[Offset]-[Assistant]-[Replace]
4.[Board]-[Fiducial]-[Assistant]-[Replace]
5.[Board]-[Badmark]-[Assistant]-[Replace]
6.[Parts]-[Assistant]-[Replace]
7.[Mark]-[Assistant]-[Replace]
Itisfixed.
3.24 1.000 TT5788
TT5788TT5788
TT5788 38
3838
38 Bug YG300 ErrorMessage
Therewasabugthat"Mounterapplicationabnormalend"occurredthroughthe
followingprocedures.
1.Themarkrecognitionfailedwhilemountingwithmorethantwotables,and"Ea51:
MARKDETECTIONERROR"occurred.
2.Tapthe[ERRORCLEAR]button.
Itisfixed.
3.24 1.000
Vis1009
Vis1009Vis1009
Vis1009
002
002002
002
39
3939
39 Bug YG300
Sideview
camera
Underthefollowingcondition,therewasabugthattheSideViewCameraimageof"B,D
table"ofYG300wasdisplayed,beingreversedupsidedown.
Thisbugwasonlyaproblemonthedisplay.Therecognitionaccuracywasnotaffected.
1.ThemounterapplicationsofV3.23STDR1.000wereused.
Itisfixed.
3.24 1.000 TT4745
TT4745TT4745
TT4745 40
4040
40 Bug YG300 History
Therewasabugthat"Mounterapplicationabnormalend"occurredthroughthe
followingprocedures.
1.[History]-[Lot]-[StageSelect]thecomboboxwasselected[DisplayAll].
2.[History]-[Production]tabclicked.
Itisfixed.
3.24 1.000 TT5541
TT5541TT5541
TT5541 41
4141
41 Bug YS100,YS88 Trace
Withthefollowingconditionandprocedures,therewasabugcausingthatauto-tracing
wasexecutedatthelowerstage,whichshouldhavebeenattheupperstage.
1.Conditions
1)[MachineSetting]-[MachineInformation]-[InstallationSetting]-[TwinPushUp]:
Exist
2.Procedures
1)ExecutedanyofthefollowingswhilemountingUpperStage
(1)Pressedthe[EmergencyStop]buttonjustaftermounting,andexecuted[Auto
trace].
(2)Executed[Autotrace]after[Ea3045:Brungbackcomponenterror]occurred.
Itisfixed.
3.24 1.000 TT5326
TT5326TT5326
TT5326 42
4242
42 Bug YS100,YS88 Trace
Throughthefollowingprocedures,abugoccurredcausingthatthefunctionoffiducial
alignmentdidn'tworkwhenteachingwasexecuted.
1.Tickedthechekboxof[Setting]-[FiducialCorreciton]onanyteachscreenof
[Board]-[Board],[Mount],[Offset],[Fiducial],[Badmark].
2.Executedtracingafterchangingthestageinthe[Teach]-[Stage]combobox.
Itisfixed.
3.24 1.000 TT5801
TT5801TT5801
TT5801 43
4343
43 Bug
YS12,
YS100,YS88
Tray
Withthefollowingconditionsandprocedures,therewasabugthatapalletinwhich
somepartsstillremainedwaschanged.
1.Conditions
1)[Parts]-[Basic]-[Package]selected[Tray]
2)[Parts]-[Basic]-[FeederType]selected[AutoTc]
3)[Parts]-[Basic]-[Pick&MountVacuumCheck]selected[SPECIALCHK]
4)[Setting]-[MachineData]-[TrayChanger]-[Position]-[Retry]-[Times]
selected"1"ormore.
5)[Setting]-[MachineData]-[TrayChanger]-[Position]-[ActioninRetryOver]
selectetd[paletteSearch]
2.Procedures
1)Pressedthe[Run]buttontostartauto-running.
2)Uncontinuousmissingtopickupoccurredinthesamepalletmoretimesbeyond
[Setting]-[MachineData]-[TrayChanger]-[Position]-[Retry]-[Times].
Itisfixed.
MDOC-VG30-00001 13/17

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNote(English) 2011/2/1
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.24 1.000 TT5494
TT5494TT5494
TT5494 44
4444
44 Bug YS24(X)DL GUI
When[Lane2]wasselectedonanyofthefollowingscreens,abugoccurredthatthe
screenwasnotupdated.
1.Setup
2.Board
3.Monitor
4.Unit
Itisfixed.
3.24 1.000 TT5823
TT5823TT5823
TT5823 45
4545
45 Bug YS24(X)DL GUI
Therewasabugthatthe[LaneChange]buttoncouldbetapped,whenthe[Save]-
[Boarddatasavedialog]-[rename]buttonsweretapped,
Itisfixed.
3.24 1.000 TT5808
TT5808TT5808
TT5808 46
4646
46 Bug YS24(X)DL History
Therewasabugthatthefollowingitemswerenotdisplayed,whentheboarddatawith
plurallaneswereloaded.
1.[MIS]-[Errorlog]grids
1)[ProgramName]oflane2
2)[ProgramComment]oflane2
Itisfixed.
3.24 1.000 TT5393
TT5393TT5393
TT5393 47
4747
47 Bug YS24(X)DS GUI
Therewasabugthatthenamepositionof"Mount1"and"Mount2"on[Unit]-
[Conveyor]-(Positioninstage2ofconveyorimage)werereversed.
Itisfixed.
3.24 1.000 TT5688
TT5688TT5688
TT5688 48
4848
48 Bug YS24(X)DS ConveyorOut
Underallofthefollowingconditions,therewasabugthattheboardtransferringfailed
becausetheconveyer1didnotrotateand"Ea2203:BOARDTRANSFERCOMMAND
TIMEOUTERROR"wasdisplayed.
1.[Board]-[Board]-[BoardSizeX(mm)]wasmorethan"330.001".
2.Theboardexistedinstage2.
3.[Unit]-[Conveyor]-[ConveyBoard]-[CarryBoardToExitPos.]-[OK]button
wasclicked.
Itisfixed.
3.24 1.000 TT5482
TT5482TT5482
TT5482 49
4949
49 Bug
YS24XSL/D
L
Recovery
Pallet
Underbothofthefollowingconditions,therewasabugthattheerror,[Ea29092Auto
TrayRecoveryPalletFullError]wasdisplayed,whichshouldnothavebeendisplayed.
1.Partsweredumpedtorecoverypalletwhilemachinestatuswasinauto-running.
2.Themagazinewasnotsetinthetraychanger.
Itisfixedsothat
"Ea29075:Auto
traychanger
Dumponlypallet
seterror"that
shouldbe
originally
displayedis
displayed.
3.24 1.000 TT5286
TT5286TT5286
TT5286 50
5050
50 Bug
YSSeries
Mounter
GUI
Therewasbugcausingthatthewrongiconsweredisplayedasfollows.
1.Theiconof"turningleft"wasdisplayedonthe[Mark]-[MarkAdjust]screenofYS
SeriesMachineregardlesstheconveyor'sdirection.
2.theiconsof[BoardCarry-In]and[BoardCarry-Out]weredisplayedinsteadof
[BoardTransfer]onbothofthefollowingscreensofYS24(X).
1)[Mark]-the[MarkAdjust]screen.
2)[Unit]-the[Conveyor]screen.
Itisfixed.
3.24 1.000 TT3365
TT3365TT3365
TT3365 51
5151
51 Bug
YSSeries
Mounter
ErrorMessage
Therewasabugthatthemessageof[Ea931:Partstandupdetectionerror]forsideview
camerawashalfwaydisplayed.
Itisfixed.
3.24 1.000 TT5514
TT5514TT5514
TT5514 52
5252
52 Bug
YSSeries
Mounter
Feeder
Therewasabugcausing"Mounterapplicationabnormalend"occurredundereitherof
thefollowingconditions.
1.FeederError(Ea30119)occurredwhileauto-running.
2.Theboardwasbeingconveyedwhenthefeedererror(Ea30119)occurred.
Itisfixed.
3.24 1.000 TT5273
TT5273TT5273
TT5273 53
5353
53 Bug
YSSeries
Mounter
ImageSave
Thereweresomecasesthataslightofwaitingforprocessingoccurredatthetimeof
partsrecognitionundereitherofthefollowingconditions.
1.On[Setting]-[MachineInformation]
1)[InstallationSetting]-[Option]-[Co-PlanarityChecker]notselected[None]
2)[SpecialSetting]-[FunctionSetting]-[VisionTest]selected[Use]
Itisfixed.
3.24 1.000 TT5012
TT5012TT5012
TT5012 54
5454
54 Bug
YSSeries
Mounter
PlanList
Therewasabugthataninternalerroroccurred,whenthe[SetUp]-[PartsSetup]
screenwasopenedwithouttheboarddatawhichhadnocomponentdata.
Itisfixed.
3.24 1.000 TT5461
TT5461TT5461
TT5461 55
5555
55 Bug
YSSeries
Mounter
PlanList
Therewasabugthatdatawassortedby[PartsNumber]insteadof[SetPosition]on
[Setup]-[PartsSetup].
Itisfixed.
3.24 1.000 TT5144
TT5144TT5144
TT5144 56
5656
56 Bug
YSSeries
Mounter
History
Therewasabugthatitwasalwaysindicated100%as[Monitor]-[PickRate]when
[Retry]-[ImmediateStop]wasselected.
Itisfixed.
3.24 1.000 TT5738
TT5738TT5738
TT5738 57
5757
57 Bug YSP
Conveyor
width
Thereweresomecasesthatprinterdidnotoutputtheboardrequestsignaltothe
upperstreammachinewheneitherofthefollowingprocedureswasrepeatedly
executed.
1.Theemergencystopbuttonwaspressedwiththeboardclampedattheprintposition.
2.Thecoverwasopenedwiththeboardclamped.
Itisfixed.
MDOC-VG30-00001 14/17