ReleaseNote_V3.24STD_R1.000_for_V30VGOS.pdf - 第16页
YAMAHAMOTORCO.,LTD. YAMAHAMOTORCO.,LTD. YAMAHAMOTORCO.,LTD. YAMAHAMOTORCO.,LTD. IMOperations IMOperations IMOperations IMOperations ReleaseNoteOption(English) 2011/2/1 Ver Ver Ver Ver Rev Rev Rev Rev N um N…

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNote(English) 2011/2/1
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.24 1.000 TT5905
TT5905TT5905
TT5905 58
5858
58 Bug YSP Fixedboard
"Ea8821:BOARDTRANSFERTIMEOUTERROR"occurredtoomuchwhenitreleased
afixedboardwhileauto-running.
Itisfixed.
3.24 1.000 TT5343
TT5343TT5343
TT5343 59
5959
59 Bug YSP Axis
Withthefollowingconditionsandprocedures,therewasabugthattheerror"Ea8920:
MASKADAPTERINTERFEREINTERLOCK"occurredalthoughthemaskadapterwas
notused.
1.Conditions
1)Loadedtheboarddatawhichdidn'tneedtobewithamaskadaptor.
2)Changedtheconveyorwidthtothe[BoardSizeY(mm)]valuebythe[Unit]-
[Conveyor]-[Width]buttons.
3)DetachthemaskadapterfromYSP.
2.Procedures
1)Startedauto-running..
2)MovedZ-axistotheprintposition,andset"ON"foreitherthefollowings.
(1)[Unit]-[I/O]-[Input]-[N0108280](ThisaddressisY-AXISORIGIN)
(2)[Unit]-[I/O]-[Input]-[N01081E4](ThisaddressisW2-AXISORIGIN)
Itisfixed.
3.24 1.000
TT5308
TT5308TT5308
TT5308
TT3970
TT3970TT3970
TT3970
60
6060
60 Bug YSP,Editor Boarddata
Therewasthebugthatthetextboxof[Print]-[Cleaner]-[CleanerInterval]returned
totheinitialvaluesthroughthefollowingprocedures,
1.Creatednewboarddata.
2.Editedthefollowingtextboxs.
[Print]-[Cleaner]-[DryAutoInterval(Board)]or[WetAutoInterval(Board)]or
[ManualAutoInterval(Board)]
Itisfixed.
3.24 1.000 TT5694
TT5694TT5694
TT5694 61
6161
61 Bug Optimizer CTEstimation
Underthefollowingconditions,therewasabugthat[Ea17904:CycleTimeEstimation
Error]occurredwhileestimatingCTanditstoppedestimating.
1.ThemachinewasYS100orYS88.
2.ThemachinewasequippedwithdYTF.
3.[Setting]-[MachineInformation]-[InstallationSetting]-[Conveyor]-[Conveyor
Direction]was"L->R".
4.Therewerepartswhosefeedertypewas"Ext.TC"intheboarddata.
Itisfixed.
3.24 1.000 TT5795
TT5795TT5795
TT5795 62
6262
62 Bug Optimizer Optimization
Thereweresomecasesthat[Ea17901:Optimizererror]occurredwhileoptimizing
underallofthefollowingconditions.
1.Theboarddatahadpartsdatawhichhadalternativeparts.
2.Therewasalittlenon-occupiedfeederspace.
Itisfixed.
MDOC-VG30-00001 15/17

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNoteOption(English) 2011/2/1
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.24 1.000 TT5570
TT5570TT5570
TT5570 1
11
1 CriticalBug
CriticalBugCriticalBug
CriticalBug YS24(X)DL
Op005:
Product
Traceability
Therewasabugthat,meanvaluesofbothlaneswereoutputinsteadof"LotLog"
Thiscausedthatmeanvaluesofbothlanesweredisplayedinsteadofappropriatedata
for[T-Tool]-[SearchMenu]-[ProductLot].
Itisfixed.
3.24 1.000 TT5602
TT5602TT5602
TT5602 2
22
2 CriticalBug
CriticalBugCriticalBug
CriticalBug YS24DS
Op005:
Product
Traceability
TherewasabugoutputtingthelothistorydatawhichwasnotabletobetakenintoT-
Toolunderthefollowingconditions.
ItbecameimpossibletosearchwithT-Toolbecausetherewerenocorrespondinglot
historytobetaken.
1.In[Setting]-[MachineInformation]-[OptionSetting]-[DetailSetting]
1)[ProductTraceability]was"Use".
2)[LotLog]was"Use".
Itisfixed.
3.24 1.000
TT5626
TT5626TT5626
TT5626
TT5644
TT5644TT5644
TT5644
3
33
3 CriticalBug
CriticalBugCriticalBug
CriticalBug IT-System
Op011:
Wireless
HandyReader
Underthefollowingcondition,therewasabugthat"Ea30350:ServerConnection
Error"occurredwhichcauseditimpossibletobeconnectedto"IT-SystemServer",or
thatXg/YGseriesmountersdidn'treacteventhoughthebarcodewasscannedfrom
"WirelessHandyReader".
1.MorethanoneIPadressweresetin"IT-SystemSerever"
(ex.2Networkcardswereused)
Itisfixed.
3.24 1.000 TT5304
TT5304TT5304
TT5304 4
44
4 Add Mounter
Op001:
Remain
Counter
Therewasabugthatthe[CurrentPosX/Y]valuewasnotupdatedautomatically,when
a[TrayRemainCount]waseditedona[Monitor]-[RemainEditor]-[TrayRemain
Count]screen.
Itismodified.
3.24 1.000 TT5754
TT5754TT5754
TT5754 5
55
5 Add Mounter
Op002:Setup
Verification
Afunctionhasbeenaddedtodisplaythe[Ea25168PartsSetupoflessthanRemain
StopCount],whenre-setupisexecutedforthetraypartsremainstopped.
Itismodified.
3.24 1.000
TP1916
TP1916TP1916
TP1916
TP1917
TP1917TP1917
TP1917
TP1948
TP1948TP1948
TP1948
6
66
6 Add IT-System
Op011:
Wireless
HandyReader
"Responsedisplay"textboxeshavebeenaddedtodisplayaresponseofthemachine
orSetupNaviwiththebarcodesscanned.
1.[MainMenu]-the[MachineMode]screen
2.[MainMenu]-the[OfflineSetupMode]screen
Itismodified.
3.24 1.000 TT4767
TT4767TT4767
TT4767 7
77
7 Bug Mounter
Op001:
Remain
Counter
Therewasabugthatthedisplayofremovedpartsdidn'tdisappear,whenthe[Monitor]-
[RemainEdit]-[ReelRemove]buttonswerepushed.
Itisfixed.
3.24 1.000 TT5437
TT5437TT5437
TT5437 8
88
8 Bug Mounter
Op002:Setup
Verification
Therewasabugthat"Mounterapplicationabnormalend"occurred,throughthe
followingprocedures.
1.Theboarddatathatusesthepalettepartswasloaded.
2.Thecartwasdetached.
3.Theboarddataforpassmoderunningwasloaded.
4."Ea29920:FEEDERCART(FRONT1)ISNOTSET"occurred.
5.The"ERRORCLEAR"buttonwastapped.
Itisfixed.
3.24 1.000 TT5470
TT5470TT5470
TT5470 9
99
9 Bug Mounter
Op002:Setup
Verification
Throughthefollowingprocedures,therewasabugcausingunnecessaryerror,
"Ea25581:PARTSSETUPINCOMPLETED",whenauto-runnningstarted.
1.Thefeederpartswereputintothestateofthesetupincompletedonlybyonepeace
offeederparts.
2.Setupfeederpart.
3.Thefeederwasattachedtothemachine.
4.TheSTARTbuttonwaspushedimmediatelybeforefeederrecognitionwascompleted.
5.TheSTARTbuttonwaspushedagainimmediatelybeforesetupcheckingwasstarted.
Itisfixed.
3.24 1.000 TT5071
TT5071TT5071
TT5071 10
1010
10 Bug Mounter
Op002:Setup
Verification
Theerrormessagesweresubdividedasfollowstogetmoreconcreteinformation,when
someabnormalitiesoccurredbysetupchecking.
[Ea2842ASSIGNMENTCHECKUN-COMPLETION]usedtobedisplayedforallofthem.
1.Whenanerroroccursinsetupcheckingbythereasonforanillegalargumentetc・・・
[Ea25113SetupCheckError]
2.Whenasetuperroroccurrswhileit'sdriving,anditbecomesimpossibletocontinue
driving・・・[Ea25114SetupCheckError]
3.Whenitfailsinthetargetdataacquisition.・・・[Ea25163SetupCheckError]
4.Whenitfailsinthenowdataacquisition.・・・[Ea25164SetupCheckError]
5.Whenaninternalerroroccursbywhichauto-runningcannotbecontinued.・・・
[Ea25165SetupCheckError]
6.Whenpartswhichhavenotdobesettingupnotexist.・・・[Ea25166SetupCheck
Error]
7.Whennotargetfileforthesetupcheckingexist.・・・[Ea25584SETUPCHECKIS
NOTCOMPLETED]
Itisfixed.
3.24 1.000 TT5790
TT5790TT5790
TT5790 11
1111
11 Bug Mounter
Op002:Setup
Verification
Therewasabugthattheverificationwasnotcompletedunderallofthefollowing
conditions.
1.Setuppluralpartsinapaletteormultisticks.
2.DifferenttypesoffeedersforthepartsabovewereregisteredinIT-System.
Itisfixed.
MDOC-VG30-00001 16/17

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNoteOption(English) 2011/2/1
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.24 1.000 TT5861
TT5861TT5861
TT5861 12
1212
12 Bug Mounter
Op002:Setup
Verification
Underallofthefollowingconditions,therewasabugcausinganunnecessarymagazine
setupscreendisplayedinstartingauto-runningorinsettinguptrayparts,anddisabled
ittostartauto-running.
1.EquippedwithATS15,andboarddataproducingtraypartswasused.
2.[SystemConfig.]-[InlineSetup]-[OP002]-[CheckObject]-[TrayParts]:"Check
not-required"
Itisfixed.
3.24 1.000 TT5069
TT5069TT5069
TT5069 13
1313
13 Bug Mounter
Op003:Auto
Program
ChangeOver
Underthefollowingconditions,thereweresomecasesthat[Ea30015:Itisimpossible
tostarttransfertotheMountPosition]occurred,eventhoughtheboardIDexistedat
thewaitingposition.
1.[Setting]-[MachineInformation]-[OptionSetting]-[DetailSetting]-[AutoPlan
Mode]was[SIGNBOARD]or[MANUALSELECT]
2.Transferfedaboardfromtheentrancetothewaitingposition.
Itisfixed.
3.24 1.000 TT5752
TT5752TT5752
TT5752 14
1414
14 Bug Mounter
Op003:Auto
Program
ChangeOver
underallofthefollowingconditions.therewasabugthatboarddatawaschangedeven
thoughthe"Cancel"buttonwasclickedonthe"Ea25614ConfirmProductionTypeis
switched"dialog.
1.Setthesettingson[Setting]-[MachineInformation]-[OptionSetting]-[Detail
Setting]asfollows.
1)[AutoPlanMode]was"SIGNBOARD".
2)[CheckProductionCountPlanAndCurrent]was"ON".
2.Theplanningproductioncountwasinput.
3.Pushed[Monitor]-[Product]-[AutoPlan]-[Kanban]-the[OK]buttonbefore
finishingtheplannedproductioncount.
Itisfixed.
3.24 1.000 TT5743
TT5743TT5743
TT5743 15
1515
15 Bug YS24(X)DL
Op003:Auto
Program
ChangeOver
[Monitor]-[Production]-[AutoPgmChange]-[KANBAN]-the[OK]buttonbecame
grayedoutandcouldn'tbetapped,throughthefollowingprocedures.
1.Tapped[Monitor]-[Production]-[AutoPgmChange]-[KANBAN]-the[OK]
buttonwiththeboardinthemachine.
2.Pressedthe[RESET]buttonwiththeboardinthemachine.
Itisfixed.
3.24 1.000 TT5686
TT5686TT5686
TT5686 16
1616
16 Bug YS24(X)DS
Op001:
Remain
Counter
Therewasabugthat[Monitor]-[Production]-[BoardCount]wassubtracted2pieces
lesserthanactuallamount,underallofthefollowingconditions.
1.BoarddatamountedbybothUpperstageandLowerstage.
2.Partsmountedby2pointsormore.
3.Whenboardcarry-outtheLowerstagewhiletheUpperstagewasmounting.
Itisfixed.
3.24 1.000 TT5606
TT5606TT5606
TT5606 17
1717
17 Bug
YSSeries
Mounter
Op001:
Remain
Counter
Op002:Setup
Verification
Therewasabugthatthetrayindicatorcolorwas"green"thoughthetraywasempty
underthefollowingcondition.
1.[SystemConfig.]-[InlineSetup]-[OP002]-[CheckObject]-[TrayParts]:"Check
not-required"
Itisfixed.
3.24 1.000 TT5516
TT5516TT5516
TT5516 18
1818
18 Bug
YSSeries
Mounter
Op002:Setup
Verification
Thereweresomecasesthat"Mounterapplicationabnormalend"occurredthroughthe
followingproceduresrepeated.
1.Attachedthecartequipppedwithfeederstothemachine.
2.Detachedthecartwhilethefeederwasbeingrecognized.
Itisfixed.
3.24 1.000 TT5668
TT5668TT5668
TT5668 19
1919
19 Bug
YSSeries
Mounter
Op002:Setup
Verification
Therewasabugthatanunnecessarymessage,"Ea25140:DRIVESYSTEM
COMBINATIONERROR"wasdisplayedwhenSSFwasquicklyattachedordetached.
Itwascorrected
thatEa25140was
notdisplayed.
MDOC-VG30-00001 17/17