00197490-03_SM_CP20-P-M2_EN保养维护.pdf - 第51页

6 Pressure control valve (PRV) 6.2 Replacing the membrane and other small parts on the PRV Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 51 Fig.64: Removing the cover ► Remove the two screws and …

100%1 / 88
6 Pressure control valve (PRV)
6.2 Replacing the membrane and other small parts on the PRV
50 Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018
●
Protective membrane:
Quantity
Description Item no.
Replacement membrane for pressure control valve C&P20P 03157917‑xx
Insertion aid for membrane 03165256‑xx
Self-tapping screw PT-WN1442-2.5X8-PT10 03119677‑xx
Membrane cover for pressure control valve 03159830‑xx
Cross-head-panhead screw ISO7045–M2x5-A2-50-H 03010198‑xx
Washer ISO7098–2–200HV–A2 03100631‑xx
O-Ring, small 03119672‑xx
Preparation
► Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
Fit the head on the head mount [03056231‑xx].
► Make sure that the component sensor protective cap is fitted.
1.1.3 "Safety instructions for the component sensor" [}6]
Removal
Fig.63: PRV parts
 CAUTION!
Do not mix up the parts
The PRV parts are aligned and are not to be
mixed with the parts of other PRVs.
.
► Remove the pressure control valve.
6.1 "Replacing the PRV" [}47]
NOTICE
Depending on the spare part to be replaced, you may not need to do all the following re-
moval steps.
6 Pressure control valve (PRV)
6.2 Replacing the membrane and other small parts on the PRV
Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 51
Fig.64: Removing the cover
► Remove the two screws and take the cover off
the PRV membrane.
Fig.65: Checking the membrane
► Carefully check the membrane for any damage.
ð If no damage can be found, close the cover
window again.
You do not need to replace the membrane in
this case.
ð If there is any damage, proceed with the next
step.
Fig.66: Removing the cover plate
► Remove the three screws fastening the cover
plate and remove the cover plate.
Fig.67: Top board
► Remove the two screws and swing the board
slightly upwards.
 CAUTION!
Make sure that you do not swing the board up
too far. If you do, this could cause the flexprint
cable to break.
Take care not to damage the sensor O-ring.
.
Fig.68: Side board
► Remove the three screws and then remove the
board.
 CAUTION!
Never loosen or remove the screw in the
middle!
.
6 Pressure control valve (PRV)
6.2 Replacing the membrane and other small parts on the PRV
52 Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018
Fig.69: O-ring on vacuum sensor
► Remove the vacuum sensor O-ring.
Fig.70: Removing the plunger
► Remove the plunger with the help of a size 10
wrench.
Fig.71: Removing the membrane
► Remove the old, damaged membrane and its
residues.