Retrofit instructions Nozzle changer SIPLACE H F-series C&P head 12/2004 Edition 25 : Place t he nozzle c hanger o nto the n ewly fitte d carrier wi th the t op facing downwards. : Connect th e compr essed ai r hose …

100%1 / 30
Retrofit instructions Nozzle changer SIPLACE HF-series C&P head
24
: Put a Y connector onto the disconnected hose.
Use the Y connector to connect the compressed air hoses of both nozzle changers.
2
2
: Plug the cables and the compressed air hose into the C&P head nozzle changer.
The cable for row 2 is marked "b".
2
2
: Only SIPLACE HF-series from serial number A-001:
Connect the second nozzle changer with the One-Wire-HUB.
2
2
2
2
2
2
Cable
Compressed
air connector
Retrofit instructions Nozzle changer SIPLACE HF-series C&P head
12/2004 Edition
25
: Place the nozzle changer onto the newly fitted carrier with the top facing downwards.
: Connect the compressed air hose to the new nozzle changer.
2
2
The wiring should look like this: 2
2
2
2
2
2
Retrofit instructions Nozzle changer SIPLACE HF-series C&P head
26
: Attach the cable for the power supply to the nozzle.
2
: Screw the nozzle changer on with four M5x12 screws.
2