TDS_AirJet_486_CRD_ENG.pdf - 第5页
AirJet ® 486 CRD TECHNICAL DATA SHEET 5 www.dct.cleaning Power supply 400V, 32A, 50Hz* (3+N+PE) 400V, 32A, 60Hz* (3+N+PE) Pmax 9,5 kW 9.5 kW Compressed air connection Pipe Ø 6 mm Pipe ID 0.24 Recommended working pressure…

AirJet
®
486 CRD
TECHNICAL DATA SHEET
4
www.dct.cleaning
Dimensions (w x l x h) 1800 x 1080 x 1150 mm 70.8 x 42.5 x 45.3 in
Weight 310 Kg 683 lbs
Ø energy consumption per cycle 1,65 kWh 1.65 kWh
Cleaning and rinsing uid consumption
per cycle
0,05 – 0,3 l 0.01 – 0.08 gal
Compressed air consumption per cycle 83 l / 5 Bar 21,93 gal / 72.5 PSI
Max. dimensions of the cleaned parts 400 x 800 x 600 mm 15.75 x 31.50 x 23.62 in
Temperature range setting of the cleaning
and rinsing uid
From ambient temperature to 60°C From ambient temperature to 140°F
Temperature range setting of the drying From ambient temperature to 80°C From ambient temperature to 176°F
Noise level < 70 dB < 70 dB
Device control PLC + 4,3“ touchscreen PLC + 4.3“ touchscreen
Volume of the storage tanks (clean, rinse) 100 l 26,42 gal
TECHNICAL PARAMETERS
DIMENSIONS
MINIMUM SERVICE SPACE
AROUND THE MACHINE
600 mm
23.6 in
600 mm
23.6 in
600 mm
23.6 in
600 mm
23.6 in
1800 mm
70.8 in
1150 mm
45.3 in
1080 mm
42.5 in
metric units imperial units

AirJet
®
486 CRD
TECHNICAL DATA SHEET
5
www.dct.cleaning
Power supply 400V, 32A, 50Hz* (3+N+PE) 400V, 32A, 60Hz* (3+N+PE)
Pmax 9,5 kW 9.5 kW
Compressed air connection Pipe Ø 6 mm Pipe ID 0.24
Recommended working pressure 2 – 4 Bar 29 – 58 PSI
Compressed air quality 3. Class ** 3. Class **
Exhaust pipe diameter Ø 100 mm ID 3.94 in
Exhaust pipe capacity 380 m
3
/h 13 400 ft
3
/hod
Minimum liquid for rst run 2 x 50 l 2 x 13,21 gal
Service space required around the device 600 mm 23.6 in
INSTALLATION REQUIREMENTS
BACK
VIEW
pressure air inlet 1x Ø 6 mm
pressure air inlet 1x Ø 0,2 mm
409 mm
16.1 in
154 mm
6.1 in
metric units imperial units
* When using frequency convertor
** According to the norm ISO 8573-1
730 mm
28.7 in
chimney
el. power input

AirJet
®
486 CRD
TECHNICAL DATA SHEET
6
www.dct.cleaning
3 process chambers – manual solution
Cleaning and rinsing uid heating
Hot air drying
Emergency stop button
Manipulation wheels – lockable
PLC controller + 4,3“ touchscreen display
Spare parts (base kit)
STANDARD HARDWARE EQUIPMENT
Standard software language mutation – CZ, ENG
Liquid and lter replacement notication – cycle counting
Possibility of 3 programs – setting option
3 levels of logging – operator, maintenance, engineer
STANDARD SOFTWARE EQUIPMENT