TT5731.Pallet Number Automatic Decision.pdf - 第4页

 SMT Software En gineering Group IM Operations Y AMAHA MOTOR CO.,L TD   MD OC-SOFT50020  4/6  4. Settings T o enable “Palle t Num ber Autom atic Decision” functi on, please s et [S et optimiza tion parameters] - [B…

100%1 / 6
SMT Software Engineering Group
IM Operations
YAMAHA MOTOR CO.,LTD
MDOC-SOFT50020
3/6
3. Specifications
This function has the following specifications. Please read the following sentences
certainly, and use it with care.
1. The following parts are not target of “Pallet Number Automatic Decision”.
The pallet numbers of the following parts might overlap.
- All tray parts when [Set optimization parameters] - [Basic Condition] - [Exec Condition] -
[Feeder Set Condition] is set to "All Parts Fixed".
- The tray parts whose [Parts] - [Option] - [Use Feeder Optimize] is set to "No".
- The parts whose parts name is the same as that of the tray parts registered in the fixed
board.
2. This function decides machines / tray changers / pallet numbers by optimization, but it does
not change the pick position ([Parts] - [Pick] - [X (mm)][Y (mm)]) etc.
When the parts needs assigning to the tray changer with different outside shape of the pallet
or differentorigin of the pallet by the optimization. Please confirm the pick up position by
teaching on the mounter.
3. This function can only assign one parts type to one pallet by optimization. Until now, if there
is some space on the pallet, the pallet can put plural parts with plural parts types on the
same pallet No, but when “Pallet Number Automatic Decision” is executed, the tray parts
which are put on one pallet become one parts type only.
Figure 3.1 A pallet after optimization
SMT Software Engineering Group
IM Operations
YAMAHA MOTOR CO.,LTD
MDOC-SOFT50020
4/6
4. Settings
To enable “Pallet Number Automatic Decision” function, please set [Set optimization
parameters] - [Basic Condition] - [Exec Option] - [Decide pallet number automatically] to
checked state” (cf. figure 4.1).
The initial value is “unchecked state”.
Figure 4.1 Setting of “Pallet Number Automatic Decision”
SMT Software Engineering Group
IM Operations
YAMAHA MOTOR CO.,LTD
MDOC-SOFT50020
5/6
In the tray parts that “No” is set on [Parts] [Option] [Use Feeder Optimize] of board data,
“Pallet Number Automatic Decision” is not executed.
When you want to use an appropriate “Pallet Number Automatic Decision” for each parts,
please use this setting.
Figure 4.2 An example of [Parts] - [Option]