Nordson_EFD_781RC_Operating_Manual.pdf - 第6页

ENCLOSURE Cabinet Size (Length x Width x Depth): 25.4 x 20.3 x 10.2 cm (10 x 8 x 4") W eight: 6.5 kg (14 lb, 6 oz) Input AC (to power supply): 100–240 VAC ~ 50/60 Hz Output V oltage (from power supply): 24 VDC — 2.7…

100%1 / 18
Preventive Maintenance
As part of maintaining continuous trouble-free use of this product, EFD recommends a few very simple
preventative maintenance checks.
1. Periodically inspect tube-to-fitting connections for proper fit. Secure as necessary.
2. Check tubing for cracks and contamination. Replace tubing as necessary.
3. Check all wiring connections for looseness. Tighten as necessary.
4. If front panel of 8040 controller requires cleaning, use a clean, soft damp rag with a mild detergent
cleaner. DO NOT USE strong solvents (acetone, MEK, etc.) as they will damage the front panel
material.
5. Dry running time should be kept to a minimum less than 5 minutes.
6. During initial pump startup and priming, pump speed should be kept low until fluid reaches the
pump. Once primed, pump speed can be increased.
Turn off pump enclosure assembly before servicing any 781RC recirculating system components.
CAUTION
Disconnect electrical
power before
servicing unit.
WARNING
Rotating Shaft.
Rotating parts and shaft can
cause severe injury. Lockout
power before removing gaurd
RoHS标准相关声明标准相关声明 (China RoHS Hazardous Material Declaration)
产品名称
Part Name
有害物质及元素
Toxic or Hazardous Substances and Elements
铅
Lead
(Pb)
汞
Mercury
(Hg)
镉
Cadmium
(Cd)
六价铬
Hexavalent
Chromium
(Cr6)
多溴联苯
Polybrominated
Biphenyls
(PBB)
多溴联苯醚
Polybrominated
Diphenyl Ethers
(PBDE)
外部接口
External Electrical
Connectors
X 0 0 0 0 0
O:表示该产品所含有的危险成分或有害物质含量依照EIP-A,EIP-B,EIP-C
的标准低于SJ/T11363-2006限定要求。
Indicates that this toxic or hazardous substance contained in all the homogeneous materials for this part, according to EIP-A, EIP-B, EIP-C is below the
limit requirement in SJ/T11363-2006.
X:表示该产品所含有的危险成分或有害物质含量依照EIP-A,EIP-B,EIP-C
的标准高于SJ/T11363-2006限定要求.
Indicates that this toxic or hazardous substance contained in all the homogeneous materials for this part, according to EIP-A, EIP-B, EIP-C is above the
limit requirement in SJ/T11363-2006.
781RC MicroMark Recirculating Spray Marking System
5www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
ENCLOSURE
Cabinet Size (Length x Width x Depth): 25.4 x 20.3 x 10.2 cm (10 x 8 x 4")
Weight: 6.5 kg (14 lb, 6 oz)
Input AC (to power supply): 100–240 VAC ~ 50/60 Hz
Output Voltage (from power supply): 24 VDC 2.7 Amp maximum
Power Requirements: 24 VDC 2.0 Amp maximum
Ambient Operating Conditions: Temperature: 5° C to 45° C (41° F to 113° F)
Humidity: 85% RH at 30° C non-condensing
Height above sea level: 2000 meters max. (6562 ft)
NEMA Rating: Type 12 and 13
PUMP
Flow Capacity: Up to 88 liters per hour
Weight: 0.385 kg (13.6 oz)
Dimensions (Length x Max. Diameter): 130.5 x 56 mm (5.14 x 2.20")
Power Input: 24 VDC 2.0 Amp maximum
Wetted Materials*: Pump body: 303SS
Gears: PEEK
Gasket: PTFE
Speed Control Signal: 0–10 volts DC
Pump Drive: Magnetic coupling
*Refer to specifications page in 781S installation guide for reference to wetted materials.
NOTE: Specifications and technical details are subject to engineering changes without prior notification.
Specifications
781RC MicroMark Recirculating Spray Marking System
6 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Introduction
How the System Operates
The 781RC MicroMark
®
Recirculating Spray Marking System was
designed specifically to deal with pigmented inks and similar liquids that
have a tendency for solids within them to settle out of solution. The main
concern with settling is that the solids tend to clog the output of the
spray valve, especially at low flow settings. The 781RC system prevents
clogging and allows the user to set the valve to low flow values.
Unlike many other spray valve systems, the 781RC Recirculation
System does not use compressed air to create system pressure and
flow. Instead, it uses a gear pump driven by a brushless direct current
electric motor. The motion of the gear pump keeps the ink mixed, and
since it is a positive displacement pump, the liquid is constantly moving.
The flow in the system is controlled by the speed of the motor, which
is adjusted by a potentiometer within the pump enclosure. The internal
flow path geometry within the 781RC* spray valve helps to prevent
settling as well. When the valve is not spraying, the flow path in the
fluid body keeps the liquid from stopping within the valve. Lastly, the
return line is oriented within the reservoir to promote mixing and prevent
settling.
*The 781RC system is also available with a 787MS-SS-RC MicroSpray
valve. Contact EFD for details.
Before You Begin Power Input Options
Electrical connection options for pump enclosure assembly
+24 volt DC input for direct
wiring of pump enclosure from
a factory supplied 24 volt bus.
Screw type connection terminal
block.
Ground connection
from the 24 volt bus.
External power supply
input connector for
universal power supply
kit P/N 7013911.
781RC MicroMark Recirculating Spray Marking System
7www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.