Metal-Powder-and-Filament-Storage-Cabinet-EN-int.pdf - 第6页
sasd asdas d 2 2

Operational
XSC-300-DN2 XSC-600-DN2 XSC-900-DN2 XTC-510-DN2 XLC-510-DN2
Humidity Set Range
0.5% - 95% RH (Ambient to Set Value)
Temperature Set Range (Optional)
2°C / 15°C / 45°C / 60°C / 100°C / 125°C (Ambient to Set Value)
Time to Reach to Set Humidity Level
<7 min. (values for 1% RH)
N2 (Nitrogen) Purity
%99,99
N2 (Nitrogen) Inlet Pressure Set
5-7 bar
N2 (Nitrogen) Inlet Connection Diameter 1/4 “
N2 (Nitrogen) Pressure Set
2 bar
N2 (Nitrohen) Flow
4.5-4.8 m³/h
Number of Doors
1 2 2 4 2
Door Lock
Automatic, Password Protected
Cabinet Specifications
UV Light
Capacity 2 x 15W
Type UV-A
Socket Type G13
Lamp Type T8
Efficiency 20,6 uW/cm2
Wavelenght 350-390 nm
Control Manuel
Extraction
Capacity 350 m3/h
Control Manuel
Heater
Capacity 2 X750 W
Heater Type Electrical Heating Elements and Fans
Insulation Material Elastomeric Rubber Foam, Thermal Conductivity < 0.036 W/mK
Control Automatic
Shelf Capacity
Material Stainless Steel
Max Pcs / Cabinet 8 16 16 36 36
Min. Shelf Height 60mm
Mounting / Demounting With Shelf Holder Parts, No Tools Required
Customized Storage Options
(Depends on Customers’ Requirement)
Sliding Shelves
Sliding Shelf Dividers
Alarm Light Bar
Type Buzzer and Two-Colored Lights, Magnetic Base
Buzzer Noise Level 70 dB (A)
Light Type and Color Yellow and Red, 12 V, 5 W Lamps
Shape and Visibility Cylindrical, 360° View
Mounting Easy Attachable with Magnetic Base Plate, Built-In Screw Holes
Connection 4-Pin XLR Connector Behind Cabinet
Sensor Specifications
Relative Humidity Measurement
Location Cabinet Inside (Standard), Cabinet Outside (Optional)
Range 0 - 99% RH
Accuracy ± 0.3% RH (0…20% RH) ± 1.5% RH (20…99% RH) (After Calibrati-
on) (Indoor Sensor)
Resolution 0.01% RH < 10% RH - 0.1% RH > 10% RH (Indoor Sensor)
Temperature Measurement
Location Cabinet Inside (Standard), Cabinet Outside (Optional)
Range -20 - +125°C
Accuracy ± 0,5°C (at 25°C)
Resolution 0.1°C
Date & Time
Date (dd.mm.yy) and Time (hh:mm:ss) Display With Real Time Clock (RTC)
Alarm Function
Alarm Type
Standard Internal Buzzer, Optional Alarm Light Bar
Alarm Duration
Adjustable, Internal Buzzer: 5 - 255 sec. Alarm L. Bar: 1 - 60 min.
Humidity Level Alarm
Adjustable Offset: 0% RH - 40% RH
Temperature Level Alarm
Adjustable Time After Door Close: 1 - 60 minutes
Door Left Open Alarm
Adjustable Time to Alarm: 10 - 240 seconds
XSC-300-DN2 XSC-600-DN2 XSC-900-DN2 XTC-510-DN2 XLC-510-DN2
METAL POWDER and FILAMENT
STORAGE CABINET

sasdasdasd
2