SOM-1863-001.pdf - 第11页
1st Edition Issued Sep., 2005 Copying Prohibited Compiled and Distributed by 0509-001 AKDES-P

6 AKDES-P
3. Recognition Condition
To validate this function, it is required to set the component library data as
follows.
(1) Component shape: Area Array
(2) Shape Data - Electrical Contact Data
All electrodes or arbitrary electrodes must be registered.
Note: At least three electrodes must be registered.
(3) Recognition Data - Recognition data set
"Manual" must be selected in this text box to set up the parameters
described in (4) and the subsequent items.
(4) Recognition Data - Back/Front ltg algo
"Auto" or "Grid Pattern" must be selected.
(5) Recognition Data - View Range Set
"Auto Selection" or "Small View" must be selected.
(6) Recognition Data - Recognition level
"80" must be set.
4. Functional Restriction
When the component library data that meets the recognition condition in "3."
is used, the following function becomes invalid.
• Polarity Detection Function
5. Component Library Data
Refer to the instruction manual "Component Library for TCM-X Series"
and "Special Specifications for BGA/CSP" for each component library
data.
3. Recognition Condition
0509-001
Reference

7 AKDES-P
6. Troubleshooting after Error Window
(Recognition Error ID)
Refer to "Vol. 4: Maintenance and Troubleshooting" in the instruction
manual (TCM-X Series) and "Special Specifications for BGA/CSP" for
the description of the recognition-error-related items.
6. Troubleshooting after Error Window (Recognition Error ID)
0509-001
Reference

1st Edition Issued Sep., 2005 Copying Prohibited
Compiled and Distributed by
0509-001
AKDES-P