TDS_InJet_888_CRD_2F_ENG.pdf - 第6页

InJet ® 888 CRD – 2F TECHNICAL DATA SHEET 6 www.dct.cleaning STANDARD HARDWARE EQUIPMENT STANDARD SOFTWARE EQUIPMENT 1 process chamber – fully automatted solution 100% closed loop uid system 4 arm rotation – electric po…

100%1 / 8
InJet
®
888 CRD – 2F 
TECHNICAL DATA SHEET
5
www.dct.cleaning
INSTALLATION REQUIREMENTS
FRONT
VIEW
TOP
VIEW
RIGHT
VIEW
1620 mm
63.8 in
1340 mm
52.8 in
1960 mm
77.7 in
170 mm
6.69 in
discharge of the fluids G 1“
input el. power
input compressed air G 1“
1005 mm
39.6 in
780 mm
30.7 in
Ø 150 mm
ID 5.91 in
metric units imperial units
Power supply 400V, 32A, 50Hz (3+N+PE) UL 400V, 32A, 60Hz* (3+N+PE)
Pmax 12 kW 12 kW
Compressed air connection Pipe Ø 6 mm, Ø 10 mm Pipe ID 0.24 and ID 0.39 in
Recommended working pressure 4,5 – 6 Bar 65.25 – 87 PSI
Compressed air quality 3. Class ** 3. Class **
Exhaust pipe diameter Ø 150 mm ID 5.91 in
Exhaust pipe capacity 380 m
3
/h 13400 ft
3
/h
Minimum liquid for  rst run 2 x 75 l 2 x 19.8 gal
Service space required around the device 600 mm 23.6 in
* When using frequency convertor
** According to the norm ISO 8573-1
InJet
®
888 CRD – 2F 
TECHNICAL DATA SHEET
6
www.dct.cleaning
STANDARD HARDWARE EQUIPMENT
STANDARD SOFTWARE EQUIPMENT
1 process chamber – fully automatted solution
100% closed loop uid system
4 arm rotation – electric powered
cleaning and rinsing uid heating
High-capacity mechanical ltration on all cycles
2 hot air blowers – drying
Chimney ap – electronically controlled
Pneumatic door lock
Emergency stop button
Manipulation wheels – lockable
Conection ready for external sandwich ltration
PLC controller + 8,4" touchscreen display
Spare parts (base kit)
Electronic process cycle counter
Electronic monitoring of uid pressure
Adjustable pump pressure cleaning/rinse process
3 levels of logging – operator, maintenance, engineer
Spraying uid pressure - continuous measurement
Standard software language mutation – CZ, ENG
Liquid and lter replacement notication – cycle counting
Possibility of 5 programs – setting option
Smart warning – low or high pressure level
Smart warning – low uid level
InJet
®
888 CRD – 2F 
TECHNICAL DATA SHEET
7
www.dct.cleaning
OPTIONAL SOFTWARE EQUIPMENT
OPTIONAL HARDWARE EQUIPMENT
OPTIONAL ACCESSORY – FRAMES AND OTHERS
OPTIONAL TRACEABILITY
Common uids draining – manual control
Automatic uids relling (without pump)
Automatic uids discharging (without pump)
Tanker 200 and 400 l – celaning/rinse uid
Heating the liquids in the tanker
Bubbling grate for tanker
Filtration sandwich – external
Conductivity measurement – rinse 0-2000 µS – blocking optional
Other optional equipment - the complete list of optional accessories will provide you DCT or the local distributor.
SW for CVA calculation (android, machine)
Adjustable timer of cleaning uid heating
Upgrade machine for PROTON
Language mutation (CZE, ENG, GER, POL, CHI, RUS, ITA, SPA, MAY, HUN)
ONLINE access to cleaning system
Mechanical basket
Mechanical basket – PCBs + 4 comb holders
Mechanical basket – PCBs without comb holders
Mechanical basket – soldering frames + paletts
Mechanical carrier stand – soldering frames + paletts (5–8 holders)
Mechanical comb holder (18 slots)
Mechanical table holder – stencil or PCB carrier frame
Mechanical manipulation trolley – one/two oor
Other optional equipment - the complete list of optional accessories will provide you DCT or the local distributor.
Traceability OFF line, CSV to SD card
Traceability OFF line, Reader, CSV to SD card
Traceability ON line, PC WIN, le
Traceability ON line, READER, PC WIN, le
Traceability ON line, PC WIN, OPC Server CD, no le
Traceability ON line, PC WIN, READER, OPC Server CD, no le