ReleaseNote_V3.42STD_R1.000_for_V30VGOS.pdf - 第10页
YAMAMA MOTOR CO., LTD IM Operations Release Note(English) 2014/6/17 Ver Rev Num Ref Item Type Keyword Contents Result Doc 3.42 1.000 VCID062 Vis1311 001 42 Bug YS Series Mounter Vision When co-planarity check was execute…

YAMAMA
MOTOR
CO.,
LTD
IM
Operations
Release
Note(English)
2014/6/17
Ver
Rev
Num
Ref
Item
Type
Keyword
Contents
Result
Doc
3.42
1.000
TT9259
28
Bug
YS24(X)DL
Axis
Under
the
following
conditions,
there
was
a
bug
that
"Ea506:
AXIS
NEAR"
occurred
on
Y-
axes.
This
may
have
caused
interference
of
Y-axes.
1.
"Module
stop"
is
used.
2.
Y-axes
moves
synchronously.
3.
Stop
the
lane
of
the
former
moving
mount
table.
Fixed
3.42
1.000
TT9052
29
Bug
YS24(X)DL
Recognition
Error
There
was
a
bug
that
"Ea944:
SIDE
VIEW
CAMERA
:
BRING
BACK
AFTER
MOUNT"
occurred
at
restarting
auto-running
under
the
following
conditions.
1.
The
"Module
Stop"
function
is
used.
2.
Auto-running
is
stopped
during
a
side
view
bring
back
check.
Fixed
3.42
1.000
TT9255
30
Bug
YS24(X)DL
History
Log
There
was
a
bug
that
an
error
rate
of
[Monitor]-[Main]
is
over
100%
under
the
following
conditions.
1.
[Setup]
-
[SoftwareSetting]
-
[History]
-
[Detail
History
Setting]
-
[Taking
over
LotLog]
is
Enabled.
2.
Board
data
is
loaded
on
both
lane,
then
it
is
unselected
or
changed
only
on
e
祀
her
lane.
Fixed
3.42
1.000
TT9271
31
Bug
YC8
Conveyor
Out
Under
the
following
conditions,
there
was
a
bug
that
a
board
was
not
transferred
to
the
mounting
pedion
or
a
non-mounted
board
was
transferred
to
the
lower
machine.
1.
[Installation
Setting]
-
[Wait
Position]
is
set
to
"Not
Use".
2.
A
board
is
stopped
at
a
position
away
from
the
mounting
position
sensor
and
the
entrance
sensor,
and
"Ea2204:BOARD
TRANSFER
ERROR"
occurs.
3.
Clear
Ea2204,
and
execute
either
of
the
following.
1)
Restart
without
moving
board.
->
The
board
was
not
transferred
to
the
mounting
position.
2)
Restart
with
moving
the
board
to
the
mounting
position.
->
The
board
was
transferred
without
mounted
to
the
lower
machine.
Fixed
3.42
1.000
TT9125
32
Bug
YS
Series
Mounter
Internal
Error
There
was
a
bug
tha
an
internal
error
occurred
at
splicing
under
the
following
conditions.
1.
Splicing
parts
are
set
on
the
cart.
2.
The
cart
is
clamped
off.
Fixed
3.42
1.000
TT9258
33
Bug
YS
Series
Mounter
Nozzle
Change
There
was
a
bug
that
nozzle
change
was
not
canceled
even
with
the
following
procedure.
1.
Execute
[Setup]
-
[Measure
Nozzles]
-
[Nozzle
MACS].
2.
Press
the
[Cancel]
button
on
the
"Ea21
104:
Getting
the
Nozzle
MACS..."
message.
*
Ea21104
disappeared,
but
the
operation
continued.
Fixed
3.42
1.000
TT8965
34
Bug
YS
Series
Mounter
Monitor
There
was
a
bug
that
the
[Monitor]
-
[Production]
screen
showed
parts
with
"Skip"
set
on
[Board]
-
[Mount]
-
[Edit]
It
is
a
display
problem.
Fixed
3.42
1.000
TT9198
35
Bug
YS
Series
Mounter
Cleaning
Blow
There
were
following
bugs
when
cleaning
blow
was
executed
with
the
[Unit]
-
[Head]
-
[Cleaning
blow]
button.
1.
Cleaning
blow
was
performed
only
on
current
nozzles,
though
[All
nozzles
that
can
be
used]
was
selected.
2.
Cleaning
blow
was
performed
on
all
nozzles,
though
[Only
using
nozzles]
was
selected.
Fixed
3.42
1.000
TT9232
36
Bug
YSH20
Axis
There
was
a
bug
that
W-axis
moved
though
PU
and
the
plunger
of
board
clamp
were
interfering
with
each
other
on
the
[Move
Axis]
screen.
This
may
have
caused
a
collision
of
the
plunger
and
the
push
up
plate.
Fixed
3.42
1.000
TT9014
37
Bug
YSP
Mark
adj
There
was
a
bug
that
the
[OK]
button
was
disabled
in
the
[Mark
Adjust]
dialog
displayed
after
mark
detection
error
occurred.
Fixed
3.42
1.000
TT8560
38
Bug
YSP
Conveyor
Out
Under
the
following
conditions,
there
was
a
bug
that
extra
board
was
carried
in
so
that
"Ea85:
Transfer
Error"
occurred.
1.
Extended
conveyor
is
used.
2.
Planed
number
of
boards
is
input.
Fixed
3.42
1.000
TT9025
39
Bug
YSP20
Cleaning
When
auto-running
stopped
during
auto
cleaning,
there
was
a
bug
that
cleaning
restarted
where
it
left
off.
*
In
this
case,
cleaning
must
start
from
the
beginning.
Fixed
3.42
1.000
TT9241
40
Bug
Optimizer
Internal
Error
There
was
a
bug
that
an
internal
error
occurred
w
祀
h
the
following
items
set
on
[Set
detai
optimization
parameters]
-
[Mount/T
ransfer
Mode].
1.
[Mount/Transfer
Mode
Decision
Method]
is
set
to
"Edit".
2.
[Mount
Mode]
is
set
to
z
,
Alternate
Lanes".
3.
[Transfer
Mode]
is
set
to
"Synchronous
Transer".
Fixed
3.42
1.000
TT9253
41
Bug
Optimizer
Internal
Error
There
was
a
case
that
an
internal
error
occurred
during
optimization
under
the
following
conditions.
1.
On
a
machine
with
multiple
stages.
2.
[Set
optimization
parameters]
-
[Feeder
Set
Condition]
is
set
to
"Move
Within
Machine".
Fixed
MDOCV30-00001
9/11

YAMAMA
MOTOR
CO.,
LTD
IM
Operations
Release
Note(English)
2014/6/17
Ver
Rev
Num
Ref
Item
Type
Keyword
Contents
Result
Doc
3.42
1.000
VCID062
Vis1311
001
42
Bug
YS
Series
Mounter
Vision
When
co-planarity
check
was
executed
under
the
following
condition,
there
was
a
possibility
that
"Ea959:
3D
RECOGNITION
TIMEOUT
ERROR"
occurred.
1.
[Parts]
-
[Shape]
-
[Alignment
Type]
is
"BGA"
Fixed
MDOCV30-00001
10/11

YAMAMA
MOTOR
CO.,
LTD
IM
Operations
Release
Note
Option(English)
2014/6/17
Ver
Rev
Num
Ref
Item
Type
Keyword
Contents
Result
Doc
3.42
1.000
7146227
1
Add
Mounter
Op002:
Setup
Verification
"Op002:
Setup
Verification"
has
been
modified
to
show
an
unused
parts
warning
with
the
following
setting.
The
initial
setting
is
"NotUse".
[System
Config]
-
[Inline
Setup]
-
[Op002]
-
[The
Other
Procedure]
-
[Non
Request
Parts
Wamig]
Modified
3.42
1.000
TT9146
2
Change
YS
Series
Mounter
Op005:
Product
Traceability
It
has
been
modified
to
display
"Ea25705:
Traceability
log
processing
error
in
the
T-Tool
server",
when
T-Tool
is
not
processing
PartsMountLog.
Modified
3.42
1.000
7M5876
3
Change
YSP20
Board
data
The
following
operations
have
become
possible
during
module
reset
1.
Loading
same
board
data
while
"Op003:Aut。
Pgm
Change
Over"
is
enabled.
2.
Editing
board
data
on
the
[Inspection]
tab
3.
Editing
adjust
position
on
the
[Print]
-
[Squeegee]
-
[Visual
Matching]
screen
Modified
3.42
1.000
TT9177
4
Bug
YS
Series
Mounter
Op001:
Remain
Counter
Op002:
Setup
Verification
There
was
a
bug
that
the
screen
freezed
under
the
following
conditions.
1.
,
zOp001
:
Remain
Counter"
or
"Op002:
Setup
Verification"
is
used.
2.
An
error
occurs
concerned
with
"Op001:
Remain
Counter"
or
"Op002:
Setup
Verification"
such
as
"Ea
12476:
Parts
remain
warning".
3.
Without
the
above
error
cleared,
board
data
is
saved
or
read.
Fixed
3.42
1.000
TT9196
5
Bug
YS
Series
Mounter
Op002:
Setup
Verification
There
was
a
rare
case
that
an
internal
error
occurred
when
a
feeder
was
removed
while
the
cart
was
moving
down.
Fixed
3.42
1.000
TT9213
6
Bug
YS
Series
Mounter
Op002:
Setup
Verification
There
was
a
bug
that
the
[monitor]
-
[production]
screen
indicated
feeders
and
grids
in
yellow
through
the
following
procedure.
1.
A
pick
up
error
occurs
on
table
C/D
during
auto-running.
2.
Clear
the
pick
up
error
of
table
C.
*
It
is
supposed
to
be
red.
Fixed
3.42
1.000
TT9257
7
Bug
Optimizer
Op014:TypeN
In
a
machine
with
//Op014:TYPE-N//,
there
was
a
bug
that
"Ea17907:File
Type
ErroKtarget
board)"
occurred
during
optimization
through
the
following
procedure.
1.
Select
lane
combined
board
data.
2.
Create
a
setting
file
on
the
[Optimizer]
-
[Set
optimization
parameters]
screen.
3.
Run
optimization
of
the
created
setting
file.
Fixed
3.42
1.000
TT9194
8
Bug
YS
Series
Mounter
Skip
Retry
There
was
a
bug
that
skip
retry
was
not
executed
under
the
following
conditions.
1.
"Op001
:
Remain
Counter"
is
used.
3.
[Board]
-
[Skip
Retry]
is
used.
4.
Tape
parts
are
used.
5.
Remain
count
of
tape
parts
reaches
stop
count
Fixed
MDOCV30-00001
11/11