ReleaseNote_V3.42STD_R1.000_for_V30VGOS.pdf - 第8页
YAMAMA MOTOR CO., LTD IM Operations Release Note(English) 2014/6/17 Ver Rev Num Ref Item Type Keyword Contents Result Doc 3.42 1.000 1P3519 15 Change Optimizer Optimization parameters When [Set optimization parameters] -…

YAMAMA
MOTOR
CO.,
LTD
IM
Operations
Release
Note(English)
2014/6/17
Ver
Rev
Num
Ref
Item
Type
Keyword
Contents
Result
Doc
3.42
1.000
7M6211
Important
Add
YS
Series
Mounter
Smart
Recognition
High-speed
Smart
Recognition
has
been
added.
This
function
reduces
recognition
time,
so
that
the
following
restrictions
have
been
removed.
1.
The
maximum
number
of
smart
recognition
parts
that
can
be
recognized
in
the
same
pickup
group
is
“T1
When
mounting
the
smart
recognition
parts
continuously,
the
mounting
operation
is
performed
one-by-one.
2.
When
a
part
with
the
model
data
having
many
edges
is
recognized,
the
recognition
result
process
is
not
completed
until
the
head
moves
to
the
mounting
pedion
completely.
As
a
result,
waiting
time
is
produced
until
the
mounting
operation
starts.
*
Note:
Smart
Recognition
parts,
created
in
earlier
version,
takes
time
as
long
as
before.
Therefore
such
parts
have
these
restrictions.
Modified
3.42
1.000
7M6192
2
Important
Add
YS
Series
Mounter
Feeder
Feeder
Maintenance
Notice
function
has
been
added.
It
notifies
that
a
feeder
requires
maintenance,
when
certain
times
of
feeding
have
been
done
since
last
maintenance.
Modified
*
3.42
1.000
7M6194
3
Important
Add
YS
Series
Mounter
Feeder
Adjustable
Stick
Feeder
(ASF)
has
been
supported.
Modified
*
3.42
1.000
7P3447
7P3448
1P3449
7P345[
7P3452
7P3453
7P3454
1P3455
4
Important
Change
All
Machine,
AIIY.
FacT
Board
Selection
"Production
Lot
Operation"
has
been
modified
as
follows.
1.
"Setup
Navi"
has
been
supported.
2.
It
works
without
"Op003:
Auto
Program
Change
Over"
Modified
*
3.42
1.000
5
Add
Mounter
Pickup
MACS
The
following
conditions
of
Pickup
MACS
have
been
added
to
the
[Monitor]
-
[Pick
Rate
Warning]
screen.
1.
Feeder
MACS:
Feeder
MACS
done
or
undone
on
[Parts
Information]
2.
Nozzle
MACS:
Nozzle
MACS
done
or
undone
on
[Head
Information]
Modified
*
3.42
1.000
1M6O36
6
Add
Mounter
Pickup
MACS
To
use
Nozzle
MACS
more
efficiently,
it
has
been
modified
to
display
a
recommended
setting
when
[Machine]
-
[Pickup
MACS]
-
[Nozzle
MACS]
is
turned
"ON".
1.
[Machine]
-
[Schedule
Specification]
O
[Shaft
Cleaning
Blow]
-
[Executive
Condition]
is
set
to
other
than
"Lot
Start
+
Auto
Running".
2.
At
least
one
,,ManualNzlChg//
nozzle
exists
on
[Machine]
-
[Head]
-
[Head
Offset]
-
[Head
Type].
Modified
*
3.42
1.000
7
Add
YC8
Dump
Dump
Station
has
been
supported.
Modified
3.42
1.000
7M6148
8
Add
YC8
Dump
It
has
been
supported
for
insertion
parts.
Also,
Force
control
option
has
been
supported.
Modified
*
3.42
1.000
7M6108
9
Change
All
Machine
Edit
window
It
has
become
possible
to
use
the
[Jump]
buttons
during
auto-running.
Modified
3.42
1.000
10
Change
Mounter
GUI
The
following
pallet
indicator
on
[Monitor]
-
[Production]
has
been
changed.
Before:
1.
The
empty
pallet
is
indicated
in
yellow
blinking.
2.
It
doesn't
work
when
"Op001
Parts
Remain
Counter"
or
z
,Op002:Setup
Verification"
is
used.
After
1.
The
empty
pallet
is
indicated
in
yellow.
2.
It
does
work
when
System
Config
of
IT-System
Server
is
set
as
below,
even
when
"Op001
Parts
Remain
Counter"
or
"Op002:Setup
Verification"
is
used.
-
[Inline
Setup]
-
[OP002]
-
[Check
Object]
-
[Tray
Parts]
is
set
to
"Check
not-
required".
Modified
3.42
1.000
1M6175
11
Change
Mounter
Part
adj
It
has
been
modified
to
display
"Ea2658:
NOZZLE
TYPE
ERROR"
when
[Parts
Adjust]
-
[Test]
is
executed
with
[nozzle
type]
set
to
"NoNzl".
*
No
error
used
to
be
displayed
before
so
that
causes
were
not
clear.
Modified
3.42
1.000
7M6038
12
Change
YS
Series
Mounter
Cleaning
Blow
It
has
become
possible
to
select
a
table
to
execute
[Unit]
-
[Head]
-
[Cleaning
Blow].
It
used
to
be
all
tables
before.
Also,
it
has
been
modified
to
display
error
table
numbers
on
the
"Ea7506:
SHAFT
CLEANING
BLOW
NOZZLE
CHECK"
message
that
is
displayed
when
cleaning
blow
is
failed.
Modified
3.42
1.000
1M6224
13
Change
YSH20
Board
Selection
Changed
the
error
message
to
display
when
reading
board
data
with
more
than
512
items
on
[Board]
-
[Height].
Before:
"Ea2589:
Failed
to
read
Board
data."
After
"Ea16312:
Failed
to
read
Height
Correction
Data."
Modified
3.42
1.000
7P3522
14
Change
Optimizer
Optimization
Optimizer
has
been
improved
to
reduce
nozzle
change
times
to
avoid
interference
with
parts.
Modified
MDOCV30-00001
7/11

YAMAMA
MOTOR
CO.,
LTD
IM
Operations
Release
Note(English)
2014/6/17
Ver
Rev
Num
Ref
Item
Type
Keyword
Contents
Result
Doc
3.42
1.000
1P3519
15
Change
Optimizer
Optimization
parameters
When
[Set
optimization
parameters]
-
[Detail]
-
[Fixed
Board]
-
[Copy
of
parts
parameters
from
the
fixed
board]
check
box
is
off,
[Parts]
-
[Comment]
is
not
copied
from
fixed
board.
([Parts]
-
[Comment]
was
always
copied
from
fixed
board
before.)
Modified
3.42
1.000
TT9245
16
Bug
Mounter
GUI
There
was
a
bug
that
an
application
abnormal
end
occurred
when
the
space
key
or
the
[ERROR
CLEAR]
button
was
continuously
pressed
in
order
to
clear
an
error
message.
Fixed
3.42
1.000
TT9075
17
Bug
Mounter
Nozzle
Type
There
was
a
bug
that
Measure
Nozzles
was
executed
for
unused
nozzle,
under
either
of
the
following
conditions.
1.
Measure
Nozzles
is
executed
when
data
check
error
occurs
at
reading
board
data.
2.
Measure
Nozzles
is
executed
after
reading
board
data
and
changing
nozzle
type
in
parts
data.
Fixed
3.42
1.000
TT9230
18
Bug
Mounter
BadMark
When
"Ea
13024:
BADMARK
RESULT
TRANSPORT
ERROR"
occurred,
there
was
a
bug
that
auto-running
wrongly
started
without
removing
the
board.
Fixed
3.42
1.000
SS2rx19
783
19
Bug
Mounter
Feeder
At
feeding
ZS
feeder,
there
was
a
bug
that
parts
were
shaken,
or
the
top
tape
was
caught
under
the
tape
guide.
Fixed
3.42
1.000
TT9247
20
Bug
Mounter
Interfere
When
machine
stopped
while
Z-axis
was
storing
or
picking
a
nozzle,
there
was
a
bug
that
Z-axis
interfered
with
the
nozzle
or
the
nozzle
station
and
overcurrent
occurred.
Fixed
3.42
1.000
TT9275
21
Bug
YGSeries,
YS12Series,
YS24Series,
YS100.YS88,
YSH20
Recognition
Under
the
following
conditions,
there
was
a
bug
that
the
head
moved
to
the
mounting
position
without
parts
recognition,
and
"Ea33:
Parts
Recognition
Error"
occurred
during
auto-running.
Also,
parts
recognition
was
not
executed
with
[Parts]
-
[PartAdj]
-
[Test]
1.
[Machine]
-
[Machine
Information]
-
[Installation
Setting]
-
[Multi
MACS]
is
set
to
"Multi
MACS
1",
"Multi
MACS
2",
"Multi
MACS
1&2".
2.
Total
of
[Parts]
-
[Shape]
-
[Body
Size
Y(mm)]
and
[Parts]
-
[Vision]
-
[Search
Area(mm)]
is
48.0mm
or
more.
3.
Parts
of
2
are
picked
by
a
nozzle
that
is
not
at
the
ends.
Fixed
3.42
1.000
E5967
22
Bug
YG12
Series,
YS12
Series
History
Log
In
the
long
board
partition
mount
ftinction,
there
were
bugs
in
the
history
log.
1.
Board
carry-out
time
(time
from
"after
latter
mount"
to
"board
back
end
passes
the
exit
position
sensor")
was
not
included
in
"Transfer
CT".
2.
Standby
time
for
downstream
machine
at
exit
pedion
was
not
included
in
"Standby
CT".
3.
When
machine
was
reset
during
"latter
half
mount",
mount
time
of
"first
half
mount"
was
not
included
in
"Mount
CT".
Fixed
3.42
1.000
TT9128
23
Bug
YS12
Series,
YS24(
X)
Series
Cleaning
Blow
When
[Machine]
-
[Machine
Data]
-
[Head]
-
[Head
Offset]
-
[Head
Type]
is
set
to
,
/ManualNzlChg/,
or
"Fixed
Nozzle",
there
was
the
bug
that
"Shaft
Cleaning
Blow"
did
not
work
at
the
first
auto-running
after
changing
board
data,
Fixed
3.42
1.000
TT9141
24
Bug
YS24(X)DL
BadMark
There
was
a
bug
that
badmark
was
not
recognised,
which
may
have
caused
misplacement
1.
[Board]
-
[Mount
Mode]
is
set
to
"Parallel
Lanes"
2.
[Board]
-
[Transfer
Mode]
is
set
to
"Synchronous
Transfer"
3.
Mounted
to
only
one
table.
4.
Carry
in
the
boards
to
lane
1
and
2
at
same
time.
Fixed
3.42
1.000
TT9188
25
Bug
YS24(X)DL
BadMark
Under
the
following
conditions,
there
was
a
bug
that
the
machine
slept
while
the
badmark
was
recognized.
1.
[Board]
-
[Mount
Mode]
is
set
to
"Parallel
Lanes"
2.
[Board]
-
[Transfer
Mode]
is
set
to
"Synchronous
Transfer"
3.
[Board]
-
[Badmark]
-
[Local]
is
used.
4.
There
is
the
local
badmark
that
does
not
set
to
the
mount
data.
It
is
set
far
position
from
the
mount
table
than
other
marks.
5.
Carry
in
the
boards
to
lane
1
and
2
at
same
time.
Fixed
3.42
1.000
TT9152
26
Bug
YS24(X)DL
Fiducial
Under
the
following
conditions,
there
was
a
bug
that
board
fiducial
is
not
recognized
on
Lane2.
1.
[Board]
-
[Mount
Mode]
is
set
to
"Parallel
Lanes"
2.
[Board]
-
[Transfer
Mode]
is
set
to
"Synchronous
Transfer"
3.
[Board]
-
[Fiducial]
-
[Board]
is
set
to
“Execute”
4.
[Machine
Data]
-
[Ma]
-
[Position]
-
[Data]
-
[Fiducial]
-[Data
Transfer]
is
set
to
“Use”
5.
The
second
or
later
board
mounted
with
synchronous
transfer
Fixed
3.42
1.000
TT9246
27
Bug
YS24(X)DL
Axis
When
W-axis
was
moved
to
narrow
between
lane
land
2
on
the
[Unit]
-
[Head]
-
[Axis
move]
screen,
there
was
a
bug
that
"Ea29558:
W-AXIS
INTERLOCK
ERROR"
occurred.
Fixed
MDOCV30-00001
8/11

YAMAMA
MOTOR
CO.,
LTD
IM
Operations
Release
Note(English)
2014/6/17
Ver
Rev
Num
Ref
Item
Type
Keyword
Contents
Result
Doc
3.42
1.000
TT9259
28
Bug
YS24(X)DL
Axis
Under
the
following
conditions,
there
was
a
bug
that
"Ea506:
AXIS
NEAR"
occurred
on
Y-
axes.
This
may
have
caused
interference
of
Y-axes.
1.
"Module
stop"
is
used.
2.
Y-axes
moves
synchronously.
3.
Stop
the
lane
of
the
former
moving
mount
table.
Fixed
3.42
1.000
TT9052
29
Bug
YS24(X)DL
Recognition
Error
There
was
a
bug
that
"Ea944:
SIDE
VIEW
CAMERA
:
BRING
BACK
AFTER
MOUNT"
occurred
at
restarting
auto-running
under
the
following
conditions.
1.
The
"Module
Stop"
function
is
used.
2.
Auto-running
is
stopped
during
a
side
view
bring
back
check.
Fixed
3.42
1.000
TT9255
30
Bug
YS24(X)DL
History
Log
There
was
a
bug
that
an
error
rate
of
[Monitor]-[Main]
is
over
100%
under
the
following
conditions.
1.
[Setup]
-
[SoftwareSetting]
-
[History]
-
[Detail
History
Setting]
-
[Taking
over
LotLog]
is
Enabled.
2.
Board
data
is
loaded
on
both
lane,
then
it
is
unselected
or
changed
only
on
e
祀
her
lane.
Fixed
3.42
1.000
TT9271
31
Bug
YC8
Conveyor
Out
Under
the
following
conditions,
there
was
a
bug
that
a
board
was
not
transferred
to
the
mounting
pedion
or
a
non-mounted
board
was
transferred
to
the
lower
machine.
1.
[Installation
Setting]
-
[Wait
Position]
is
set
to
"Not
Use".
2.
A
board
is
stopped
at
a
position
away
from
the
mounting
position
sensor
and
the
entrance
sensor,
and
"Ea2204:BOARD
TRANSFER
ERROR"
occurs.
3.
Clear
Ea2204,
and
execute
either
of
the
following.
1)
Restart
without
moving
board.
->
The
board
was
not
transferred
to
the
mounting
position.
2)
Restart
with
moving
the
board
to
the
mounting
position.
->
The
board
was
transferred
without
mounted
to
the
lower
machine.
Fixed
3.42
1.000
TT9125
32
Bug
YS
Series
Mounter
Internal
Error
There
was
a
bug
tha
an
internal
error
occurred
at
splicing
under
the
following
conditions.
1.
Splicing
parts
are
set
on
the
cart.
2.
The
cart
is
clamped
off.
Fixed
3.42
1.000
TT9258
33
Bug
YS
Series
Mounter
Nozzle
Change
There
was
a
bug
that
nozzle
change
was
not
canceled
even
with
the
following
procedure.
1.
Execute
[Setup]
-
[Measure
Nozzles]
-
[Nozzle
MACS].
2.
Press
the
[Cancel]
button
on
the
"Ea21
104:
Getting
the
Nozzle
MACS..."
message.
*
Ea21104
disappeared,
but
the
operation
continued.
Fixed
3.42
1.000
TT8965
34
Bug
YS
Series
Mounter
Monitor
There
was
a
bug
that
the
[Monitor]
-
[Production]
screen
showed
parts
with
"Skip"
set
on
[Board]
-
[Mount]
-
[Edit]
It
is
a
display
problem.
Fixed
3.42
1.000
TT9198
35
Bug
YS
Series
Mounter
Cleaning
Blow
There
were
following
bugs
when
cleaning
blow
was
executed
with
the
[Unit]
-
[Head]
-
[Cleaning
blow]
button.
1.
Cleaning
blow
was
performed
only
on
current
nozzles,
though
[All
nozzles
that
can
be
used]
was
selected.
2.
Cleaning
blow
was
performed
on
all
nozzles,
though
[Only
using
nozzles]
was
selected.
Fixed
3.42
1.000
TT9232
36
Bug
YSH20
Axis
There
was
a
bug
that
W-axis
moved
though
PU
and
the
plunger
of
board
clamp
were
interfering
with
each
other
on
the
[Move
Axis]
screen.
This
may
have
caused
a
collision
of
the
plunger
and
the
push
up
plate.
Fixed
3.42
1.000
TT9014
37
Bug
YSP
Mark
adj
There
was
a
bug
that
the
[OK]
button
was
disabled
in
the
[Mark
Adjust]
dialog
displayed
after
mark
detection
error
occurred.
Fixed
3.42
1.000
TT8560
38
Bug
YSP
Conveyor
Out
Under
the
following
conditions,
there
was
a
bug
that
extra
board
was
carried
in
so
that
"Ea85:
Transfer
Error"
occurred.
1.
Extended
conveyor
is
used.
2.
Planed
number
of
boards
is
input.
Fixed
3.42
1.000
TT9025
39
Bug
YSP20
Cleaning
When
auto-running
stopped
during
auto
cleaning,
there
was
a
bug
that
cleaning
restarted
where
it
left
off.
*
In
this
case,
cleaning
must
start
from
the
beginning.
Fixed
3.42
1.000
TT9241
40
Bug
Optimizer
Internal
Error
There
was
a
bug
that
an
internal
error
occurred
w
祀
h
the
following
items
set
on
[Set
detai
optimization
parameters]
-
[Mount/T
ransfer
Mode].
1.
[Mount/Transfer
Mode
Decision
Method]
is
set
to
"Edit".
2.
[Mount
Mode]
is
set
to
z
,
Alternate
Lanes".
3.
[Transfer
Mode]
is
set
to
"Synchronous
Transer".
Fixed
3.42
1.000
TT9253
41
Bug
Optimizer
Internal
Error
There
was
a
case
that
an
internal
error
occurred
during
optimization
under
the
following
conditions.
1.
On
a
machine
with
multiple
stages.
2.
[Set
optimization
parameters]
-
[Feeder
Set
Condition]
is
set
to
"Move
Within
Machine".
Fixed
MDOCV30-00001
9/11